ABB 1SBL351074R8100 Block Contactor - 690V AC-3

Part Number: 1SBL351074R8100
Manufacturer
ABB
Part number
1SBL351074R8100

Quick Summary

ABB 1SBL351074R8100 Block Contactor is a 3-pole, AC-operated device designed to safely switch three-phase motors up to 690 V. It integrates a 24 V control circuit with AC operation and supports optional auxiliary contact blocks for side mounting, making it versatile for control panels. In demanding industrial environments, reliability and a compact footprint matter; this model delivers with a robust block-type design, precise tightening torques, and IP20 coil terminals for safe coil operation. Key certifications including CE conformity, UL/CSA recognition, and CCC/ROHS compliance ensure regulatory peace of mind across global sites. For procurement, it pairs with ABB's accessory ecosystem and CAD drawings for quick integration, enabling faster project timelines and reduced downtime.

Product Information

Extended Description

1SBL351074R8100 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 50 A | (440 V) 55 °C 45 A | (500 V) 55 °C 45 A | (690 V) 55 °C 35 A | (380 / 400 V) 55 °C 50 A | (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW | (440 V) 25 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 5 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522403810
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707356
Feature 1: Three main normally-open contacts provide direct, reliable control of three-phase motors up to 690 V. Business impact: reduces motor-switching failures and downtime while supporting standard control logic. Application: wiring in motor starters for conveyors, pumps, and processing equipment. Feature 2: 24 V control circuit voltage with 50/60 Hz compatibility simplifies PLC/drive integration and enables consistent control across global plants. Business impact: lowers wiring complexity and procurement costs, accelerates commissioning. Application: machine control panels and remote motor control. Feature 3: IP20 coil terminals and IP10 main terminals offer rugged protection in industrial environments with straightforward wiring and maintenance. Business impact: enhanced safety and reduced repair cycles. Application: panel-mounted assemblies in manufacturing environments. Feature 4: Mechanical and electrical ratings include Ie, Ie AC-3, Icw, and breaking capacity suited to motor load profiles, supporting predictable startup currents and short-circuit resilience. Business impact: protects feeders and drives, lowers spare parts inventory. Application: heavy-duty motor starters in process lines. Feature 5: Compact footprint (70 mm width, 110 mm depth, 108 mm height) and 1.01 kg weight enable easy enclosure fitment and space optimization. Business impact: smaller panel footprints, reduced enclosure costs. Application: compact control enclosures. Feature 6: Broad certification and compliance (CE, UL/CSA, CCC, RoHS) ensure global applicability and regulatory alignment for multinational projects. Business impact: faster cross-border deployments and simplified vendor qualification. Application: international plant rollouts for OEMs and integrators.

Get a Quick Quote for a ABB 1SBL351074R8100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL351074R8100? Enquire Now

FAQs

The unit uses a 24 V control circuit and 50/60 Hz. It employs screw terminals for reliable electrical connections, enabling straightforward integration with common PLCs and soft starters. Optional auxiliary contact blocks can simplify wiring schemes and provide additional feedback signals for automation sequences.
Rated Operational Current AC-1 (Ie) includes values around 85–100 A depending on voltage and ambient temperature (e.g., 690 V at 40 °C). AC-3 ratings vary by voltage (e.g., ~35–53 A). Short-time withstand current (Icw) is specified up to 1000 A for short pulses, supporting safe motor starting and fault tolerance in free-air conditions.
Yes. With 3 main NO contacts, 690 V insulation, and 3-pole configuration, it is designed for 3-phase motor control in heavy-duty applications such as conveyors, pumps, and packaging lines. Its robust mechanical design and accessory compatibility improve reliability and reduce maintenance downtime.
The device carries CE conformity, UL/CSA recognition, CCC, CQC, and RoHS compliance. This suite supports global deployments, supplier qualification, and regulatory adherence across North America, the EU, and Asia-Pacific regions.
The screw-terminal design, compact footprint, and standard accessories streamline installation and servicing. The integrated coil protection and high breakdown capacity reduce ancillary components, while the compact size minimizes enclosure space and installation time, yielding faster project completion and lower total cost of ownership.