Quick Summary

ABB 1SBL351074R8300 Block Contactor is designed to reliably switch three-phase motors up to 690 V AC in industrial power circuits. Engineers often face panel space constraints, coil wear, and the challenge of meeting high-voltage switching requirements in compact control cabinets. This device carries UL and CE certifications and RoHS compliance to meet global electrical standards. With compact dimensions, low coil power and robust insulation, it reduces downtime and simplifies procurement for motor control applications. The unit’s 3 NO main contacts and available add-on auxiliary blocks support flexible control schemes, while the 48 V, 50/60 Hz coil aligns with common PLC outputs, delivering dependable performance in automation lines.

Product Information

Extended Description

1SBL351074R8300 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 50 A | (440 V) 55 °C 45 A | (500 V) 55 °C 45 A | (690 V) 55 °C 35 A | (380 / 400 V) 55 °C 50 A | (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW | (440 V) 25 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 5 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522403834
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main poles in a block contactor design enable direct, reliable switching of three-phase loads. Business impact: Reduces wiring complexity and panel footprint, enabling tighter control cabinets and faster installation in conveyors and pumps. Application: Suitable for motor-control applications in manufacturing lines where space is at a premium and robust 690 V insulation is required. Feature: Control circuit voltage of 48 V at 50/60 Hz. Business impact: Safe, PLC-friendly coil drive that lowers control wiring costs and improves integration with standard automation systems. Application: Ideal for automation panels in process and packaging lines requiring low-voltage control without sacrificing performance. Feature: Rated operational current AC-3 up to 35–50 A and AC-1 up to 85–100 A depending on voltage. Business impact: Supports medium-power motors with clear duty-cycle specs, reducing oversizing and providing predictable performance. Application: Direct-medial motor control for fans, pumps, and small conveyors in machine rooms. Feature: Low power loss per pole (AC-1 5 W, AC-3 1.3 W). Business impact: Improves energy efficiency, lowers heat in enclosures, and extends device life in continuous operation. Application: Continuous-duty motor control in packaging lines and process automation. Feature: IP20 coil terminals and IP10 main terminals with screw connections and defined tightening torques. Business impact: Safer and easier field installation, plus reliable torque maintenance reduces connection looseness. Application: Field-installed control panels where high reliability and straightforward maintenance are required. Feature: Compact dimensions (70 mm W x 110 mm D x 108 mm H) and weight (1.01 kg). Business impact: Saves enclosure space and simplifies logistics and spare-part stocking. Application: Tight-control cabinets in automotive, food & beverage, and general manufacturing.

Get a Quick Quote for a ABB 1SBL351074R8300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL351074R8300? Enquire Now

FAQs

Install the 3-pole block contactor with its main terminals using screw connections rated IP10 for the main circuit and IP20 for the coil terminals. Use the recommended tightening torques (Main 4 N·m, Control 1 N·m) to ensure secure connections. If needed, add-on auxiliary contact blocks can be mounted on the side; verify 48 V coil operation (50/60 Hz) and confirm 690 V insulation for safe operation.
At 220/240 V, Ie is 85 A for AC-1; at 690 V, Ie is 100 A for AC-1, with 70 A at 690 V and 70 °C. For AC-3, ratings include 50 A at 415 V, 45 A at 440–500 V, and 35 A at 690 V (55 °C). These figures enable precise motor-control sizing for pumps, fans, and conveyors.
Yes. The 3NO main contacts support typical motor-start/stop sequences in pumps and conveyors, with AC-3 ratings appropriate for starting and running induction motors. The compact footprint and 48 V control coil simplify integration with PLCs, while the 690 V insulation supports robust operation in diverse process environments.
The unit ships with UL and CE certifications and RoHS compliance. It also has a Declaration of Conformity and CB/CCC references in the certificate suite, ensuring global electrical-standard alignment and traceability for regulated markets.
The contactor delivers low coil fade with power losses of 5 W per pole in AC-1 and 1.3 W per pole in AC-3, reducing heat and energy consumption in continuous operation. This translates to longer component life, lower enclosure cooling needs, and favorable total cost of ownership in automated lines.