ABB 1SBL351074R8311 Block Contactor - CE UL 690V 3P

Part Number: 1SBL351074R8311
Manufacturer
ABB
Part number
1SBL351074R8311

Quick Summary

ABB 1SBL351074R8311 Block Contactor enables reliable three‑phase motor control in industrial power circuits up to 690 V. This solution addresses downtime and arcing challenges by providing a robust, compact block design with clear, field‑adjustable accessory options. The device carries CE conformity, UL certification, and RoHS compliance to support regulatory alignment across global plants. Designed for quick installation and straightforward maintenance, it delivers consistent performance in demanding environments. By combining a 3‑pole main circuit with a single auxiliary contact block and broad CAD compatibility, it supports efficient panel wiring, scalable automation, and safer machine start‑ups for OEMs and maintenance teams alike.

Product Information

Extended Description

1SBL351074R8311 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 50 A | (440 V) 55 °C 45 A | (500 V) 55 °C 45 A | (690 V) 55 °C 35 A | (380 / 400 V) 55 °C 50 A | (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW | (440 V) 25 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 5 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522404831
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The block contactor uses 3 NO main contacts plus 1 NO/1 NC auxiliary contact, enabling reliable motor start/stop sequencing and simplified logic integration in automated lines. This translates to improved commissioning speed and reduced wiring complexity on conveyors and pumps. Application: Ideal for 3‑phase motor control in machines that require predictable switching and expandable control logic. Feature → Business Impact → Application: Rated for 690 V main and auxiliary circuits with 50/60 Hz control, ensuring broad compatibility with international equipment and minimizing conversion costs during plant expansion. Application: Suitable for global OEMs deploying multi‑site installations. Feature → Business Impact → Application: Ith of 100 A and AC‑3 current ratings up to 53 A at 690 V enable safe switching of heavy loads with controlled arc suppression. Application: Power transmission to large motors with high inrush demands. Feature → Business Impact → Application: 6 kV impulse withstand and 1300 A maximum breaking capacity provide robust protection against switching transients. Application: Critical in high‑energy applications and safety‑mocused panel designs. Feature → Business Impact → Application: Coil rated 48 V at 50/60 Hz with IP20 coil terminals and IP10 main terminals enhance safe cabinet integration and reliability in dry industrial environments. Application: Durable in control cabinets with tight space and frequent cycling. Feature → Business Impact → Application: Compact 82 mm width and 110 mm depth facilitate side‑mount accessory blocks and CAD drawing consistency, reducing BOM risk and easing aftermarket sourcing. Application: Used in new builds and retrofits where space is at a premium. Feature → Business Impact → Application: Power loss of 5 W per pole (AC‑1) and 1.3 W per pole (AC‑3) lowers energy consumption in continuous operation and reduces heat load inside enclosures. Application: Beneficial for long‑term running costs and thermal management in large control panels. Feature → Business Impact → Application: Optional add‑on auxiliary contact blocks support customized control logic without replacing the main contactor. Application: Enables scalable automation upgrades and future proofing of motor control circuits.

Get a Quick Quote for a ABB 1SBL351074R8311

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL351074R8311? Enquire Now

FAQs

Yes. The block contactor is rated for main and auxiliary circuits up to 690 V AC, with a rated control voltage of 48 V at 50/60 Hz, making it compatible with standard European and North American three‑phase motor installations.
The device provides AC‑3 rated current specifications that vary with voltage and temperature; for 690 V operation at 40 °C, Ie is 100 A, with de‑rating at higher temperatures (e.g., 70 °C reduces Ie). Specific values are listed in the datasheet and must be consulted for exact operating points in your application.
Key certifications include CE Conformity, UL Certificate, and RoHS compliance. These attest to safety and regulatory compliance for European, North American, and environmental standards, reducing compliance risk for product launches, OEM approvals, and cross‑regional deployments.
Install with screw terminals, follow the specified tightening torques (Main circuit 4 N·m, Control circuit 1 N·m), and respect IP ratings (coil IP20, main IP10). Use appropriate auxiliary contact blocks if needed and verify the device is mounted in a ventilated cabinet within the ambient temperature range to prevent overheating.
The combination of high‑current AC‑3 capability, compact footprint, optional auxiliary contacts, and robust electrical life reduces panel size, wiring time, and downtime. This translates to lower installation costs, faster commissioning, and improved machine uptime—delivering a favorable total cost of ownership for OEMs and maintenance teams.