ABB 1SBL351074R8600 Block Contactor - 690 V CE UL

Part Number: 1SBL351074R8600
Manufacturer
ABB
Part number
1SBL351074R8600

Quick Summary

ABB 1SBL351074R8600 Block Contactor is a 3-pole, AC-operated device designed to control 3-phase motors up to 690 V. In demanding production environments, downtime from unreliable switching can erode productivity and increase maintenance costs. This contactor family delivers dependable operation with a compact footprint, robust thermal performance, and straightforward maintenance to minimize service time. It carries CE and UL certifications, RoHS and REACH declarations, and features IP20 coil terminals for control-circuit protection while main terminals stay IP10. Its compatibility with add-on auxiliary contact blocks and a broad range of accessories simplifies installation and future expansion, delivering safer, faster motor control in industrial automation and machine-building applications.

Product Information

Extended Description

1SBL351074R8600 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 85 A | (690 V) 40 °C 100 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 50 A | (440 V) 55 °C 45 A | (500 V) 55 °C 45 A | (690 V) 55 °C 35 A | (380 / 400 V) 55 °C 50 A | (220 / 230 / 240 V) 55 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 25 kW | (440 V) 25 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 5 W | at Rated Operating Conditions AC-3 per Pole 1.3 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522403865
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three NO main contacts in a 3-pole block design. Benefit: Simplifies wiring, reduces enclosure space, and enhances reliability for motor control in conveyors and pumps. Application: Industrial machinery and packaging lines. Feature: Coil voltage options for 50 Hz and 60 Hz systems (400–415 V / 415–440 V). Benefit: Global compatibility and reduced stocking of separate coils, enabling quick deployment across international sites. Application: Global manufacturing facilities and OEM machines. Feature: Rated insulation voltage of 690 V and AC-1 / AC-3 operation. Benefit: Broad motor-control capability with safe isolation margins, enabling compliant integration into diverse power circuits. Application: Pumps, fans, and conveyor drives. Feature: Power loss of 5 W per pole (AC-1) and 1.3 W per pole (AC-3). Benefit: Lower energy consumption and reduced heat, improving panel efficiency and reliability. Application: Continuous-duty motor control. Feature: Compact dimensions (70 mm W x 110 mm D x 108 mm H) and weight (1.01 kg) with screw terminals. Benefit: Easy panel-fit, straightforward wiring, and quick replacement in retrofit projects. Application: Control panels and machine tool cabinets. Feature: Add-on auxiliary contact blocks and broad accessory range. Benefit: Scalable control circuits and simplified future logic expansion without replacing the base device. Application: Customized control logic for complex automation tasks.

Get a Quick Quote for a ABB 1SBL351074R8600

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL351074R8600? Enquire Now

FAQs

Yes. It is a 3-pole AC-operated block contactor rated up to 690 V, designed for three-phase motors. Its 50/60 Hz coil options (400–415 V or 415–440 V) support global installations, and its screw-terminal design simplifies panel wiring and replacements in conveyors, pumps, and other automation equipment.
The device provides AC-3 rated currents varying by voltage: 53 A at 220–240 V, 50 A at 415 V, 45 A at 440–500 V, 35 A at 690 V, with 55 °C ambient conditions. These values support reliable motor starting for typical industrial loads while maintaining safe operating margins.
Absolutely. The AX50–AX80 family supports add-on auxiliary contact blocks for side mounting, enabling expanded control logic without replacing the base unit. This is ideal for machines requiring interlocks, signaling, or remote status indicators in automated lines.
The unit is CE and UL certified, RoHS and REACH compliant, with a 690 V insulation rating and supported declarations. It also aligns with IEC 60947-4-1 requirements and related safety standards, facilitating procurement across regulated industries.
Low coil power (5 W per pole for AC-1, 1.3 W per pole for AC-3) reduces heat and energy consumption, potentially lowering cooling loads. The compact form factor, ease of replacement, and accessory compatibility simplify maintenance and future-proof automation investments, contributing to lower lifecycle costs and faster repair times.