ABB 1SBL361201R3400 Block Contactor - 690V IEC/UL
Part Number: 1SBL361201R3400
Quick Summary
Block Contactor from ABB controls four-pole power circuits in industrial automation applications. Engineers often struggle to source a compact, reliable device that fits standard DIN rails and screw terminals while delivering consistent switching performance across 50/60 Hz control voltages. This ABB contactor carries CE and UKCA conformity, UL/CSA listings, and additional third‑party certifications, providing global compliance for diverse installations. The device is designed for AF platform compatibility, easily extended with add‑on auxiliary contact blocks, and supports a wide operating temperature and altitude range. Together with DIN rail mounting and a compact footprint, this solution translates into reduced installation time, lower integration risk, and predictable lifecycle costs for industrial facilities.
Product Information
Extended Description
1SBL361201R3400 ABB: The AFC52-40-00-34 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 100 A (IEC AC-1) or 80 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 175 V AC 50 Hz / 208 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 175 V | 60 Hz 208 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523024489
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 4-pole, 4 NO main contacts in a compact block form factor. Benefit: Enables reliable control of high-current power circuits with a small footprint, reducing panel space and wiring complexity for industrial control panels. Application: Suitable for AC-1 and AC-3 duty across voltages up to 690 V, improving installation efficiency in motor and pump applications. Feature: Coil voltage options 175 V AC 50 Hz or 208 V AC 60 Hz. Benefit: Flexible control voltage compatibility supports global installations and minimizes spare parts inventory. Application: AC control circuits in mixed-voltage environments where local utility standards vary. Feature: Screw terminals and DIN rail mounting compatibility (TH35-15 or TH35-7.5). Benefit: Faster, vibration-resistant wiring and straightforward retrofits on existing control panels. Application: Panel upgrades and new machine builds with standard DIN rails. Feature: Wide operating temperature and altitude tolerance. Benefit: Maintains performance in harsh industrial settings, reducing failure risk and service calls. Application: Outdoor or high-altitude installations where ambient conditions vary. Feature: High breaking capacity and robust mechanical life. Benefit: Improves uptime and reduces maintenance costs in demanding automation lines. Application: Heavy start/stop cycles in conveyors, compressors, and pumps. Feature: Extended accessory ecosystem (auxiliary contact blocks, etc.). Benefit: Scales with control logic needs while preserving compact footprint. Application: Customizable control circuits and remote signaling for modern control architectures.
Get a Quick Quote for a ABB 1SBL361201R3400
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL361201R3400?
Enquire Now
FAQs
This four-pole block contactor supports DIN rail mounting on TH35-15 or TH35-7.5 rails and can also be mounted by screws with diagonally placed M4 or M6 hardware. The combination of DIN-rail compatibility and screw-terminal connections simplifies panel upgrades and new installations while maintaining secure, vibration-resistant mounting in harsh environments.
Main circuit rated up to 690 V with AC-1 current up to 100 A at 40 °C, 80 A at 60 °C, and 70 A at 70 °C; AC-3 ratings vary by voltage (e.g., 53 A at 415–690 V). Coil voltage options are 175 V AC 50 Hz or 208 V AC 60 Hz. Auxiliary circuits feature 6 kV impulse withstand, with IP20 protection on coil and auxiliary terminals.
Yes, the 4-pole design supports AC-1 and AC-3 duty with rated operational currents aligning to 100 A at 690 V (AC-1) and up to 53 A for several AC-3 voltage conditions. It provides robust switching performance with a maximum mechanical switching frequency of 3600 cycles per hour and a maximum electrical switching frequency of 600 cycles per hour, ensuring reliability in frequent switching scenarios.
The device carries CE and UKCA declarations, UL/CSA listings, BV, DNV and RINA certificates where applicable, and DoC conformance for AFC series. It also adheres to RoHS and REACH requirements, with WEEE classification for business-to-business use, supporting global procurement and regulatory compliance across industries.
The contactor offers low coil power loss per pole (6.3 W at AC-1, 1.7 W at AC-3 per pole) and reasonable mechanical wear rates, contributing to reduced energy costs and longer service life. Its compatibility with add-on auxiliary blocks enables scalable control logic while maintaining a compact footprint, translating to lower installation time and improved uptime.