ABB 1SBL361201R4200 Block Contactor - IEC/EN 60947-4-1

Part Number: 1SBL361201R4200
Manufacturer
ABB
Part number
1SBL361201R4200

Quick Summary

Block Contactor ABB 1SBL361201R4200 switches AC power in machine control. Many engineers struggle with coil voltage compatibility and installation complexity in control panels today. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60947-1, with IP20 protection for auxiliary terminals and IP10 for main terminals. Coil voltage options include 230-240 V AC 50/60 Hz or 277 V AC 60 Hz to cover global control circuits. Main circuit supports up to 100 A IEC AC-1, enabling direct control of motors and pumps with a single unit. With DIN rail mounting and screw-terminal connections, it integrates smoothly into existing AFC contactor families and simplifies panel design. This solution delivers reliable uptime, lower installation risk, and cost savings through standardized components and common accessories.

Product Information

Extended Description

1SBL361201R4200 ABB: The AFC52-40-00-42 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 100 A (IEC AC-1) or 80 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 277 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 277 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523023420
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Four NO main contacts and four poles enable direct control of high-power circuits without additional relays. Business Impact: Reduces wiring complexity, improves switching reliability, and minimizes enclosure footprint. Application: Suitable for motor control, conveyors, and pumps in compact control panels. Feature: Coil voltage options include 230-240 V AC at 50/60 Hz and 277 V AC at 60 Hz. Business Impact: Supports global installation without voltage adapters, simplifying procurement and spare part management. Application: Global machine builders and multi-region installations benefit from a universal coil range. Feature: IEC/EN 60947-4-1 and UL 60947-4-1 compliance with high main-circuit insulation voltage (Ui 690 V). Business Impact: Ensures regulatory alignment and safer high-voltage switching, reducing risk during commissioning. Application: Essential for industrial automation projects with IEC/UL baselines. Feature: DIN rail mounting (TH35-15 or TH35-7.5) and robust screw-terminal connections. Business Impact: Fast, secure installation with scalable panel design and straightforward field maintenance. Application: Ideal for retrofit projects and new builds in metalwork, packaging, and material handling. Feature: Add-on auxiliary contact blocks and a broad accessory range. Business Impact: Extends functionality without replacing the base unit, lowering lifecycle costs. Application: Flexible control logic expansion for complex automation schemes. Feature: Low coil power consumption (AC-1 6.3 W per pole; AC-3 1.7 W per pole) and defined operating/hold times. Business Impact: Reduces heat, energy use, and cooling requirements in panels; improves overall efficiency. Application: Continuous operation in demanding environments such as HVAC drives and pumps.

Get a Quick Quote for a ABB 1SBL361201R4200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL361201R4200? Enquire Now

FAQs

Yes. The device supports DIN rail mounting using TH35-15 or TH35-7.5 rails and employs screw terminals for both main and control circuits. This combination provides secure, vibration-resistant wiring and a straightforward retrofit path within existing AFC contactor systems, reducing installation time and potential wiring errors.
Main circuit rated up to 690 V with 4 NO contacts (4P). Rated operational current AC-1 is up to 100 A at 40 °C, 80 A at 60 °C, and 70 A at 70 °C. For AC-3, ratings vary by voltage (e.g., 53 A at 415–440 V, 53 A at 380/400 V, and 35 A at 690 V). Coil voltage options are 230–240 V at 50/60 Hz or 277 V at 60 Hz.
Yes. With four NO contacts and 4P configuration, it is well-suited for motor control in conveyors, pumps, and fans. Its AC-1 and AC-3 ratings cover start/stop control and running power for small to medium motors, while the 690 V insulation voltage accommodates modern industrial drives.
The product meets IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, and CSA equivalents. It also provides IP20 protection for auxiliary terminals and IP10 for main terminals, along with REACH, RoHS, and other declarations, aiding conformity in international panels and machine builds.
Low coil power (6.3 W AC-1 per pole; 1.7 W AC-3 per pole) reduces heat and energy consumption. Built-in modularity with add-on auxiliary contacts and compatibility with AFC accessories minimizes spare parts, extends service life, and shortens downtime during upgrades or maintenance.