ABB 1SBL361201R5100 Block Contactor - 690V IEC/UL

Part Number: 1SBL361201R5100
Manufacturer
ABB
Part number
1SBL361201R5100

Quick Summary

The ABB 1SBL361201R5100 Block Contactor delivers reliable AC power switching for industrial machinery up to 100 A. It helps panel builders overcome space and wiring challenges with a compact 70 mm width, 119.5 mm depth and 113.5 mm height, plus screw terminals for straightforward installation. It complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, and carries CE and UKCA declarations, ensuring broad regulatory alignment. Designed for AFC control applications, it supports add-on auxiliary contact blocks and a wide range of accessories, delivering a tailored solution for motor control, conveyors, and automation panels.

Product Information

Extended Description

1SBL361201R5100 ABB: The AFC52-40-00-51 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 100 A (IEC AC-1) or 80 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523024496
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 4-pole block design with 4 NO main contacts simplifies high-current AC switching, reducing device count and boosting reliability in machine control. This translates to faster installation and lower panel footprint in conveyor lines and presses. Feature → Application: Coil voltages of 400–415 V AC at 50/60 Hz or 480 V at 60 Hz enable direct compatibility with common control circuits, minimizing wiring errors and enabling rapid commissioning in automated lines. Feature → Business Impact → Application: Rated operational currents (Ie) up to 100 A at 690 V (AC-1) and 53 A (AC-3) at multiple voltages support motor and load control without overrating, delivering energy efficiency and cost savings in pump and fan networks. Feature → Compatibility → Application: DIN rail mounting options TH35-15 or TH35-7.5 plus screw mounting support quick, secure installation in standard panel configurations; compatible with add-on auxiliary blocks for expandable control. Feature → Reliability → Application: Mechanical and electrical ability to withstand up to 3600 cycles per hour (mechanical) and 600 cycles per hour (electrical) ensures long service life in demanding production lines, reducing maintenance and downtime. Feature → Compliance & Accessories → Application: Broad certification footprint (IEC/UL/CSA with CE/UKCA declarations) and compatibility with accessories provide a future-proof solution for regulated industries like packaging, material handling, and process automation.

Get a Quick Quote for a ABB 1SBL361201R5100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL361201R5100? Enquire Now

FAQs

Mounting is supported on TH35-15 or TH35-7.5 DIN rails, with two screws (M4 or M6) for secure attachment. Main circuit connections use rigid or flexible conductors up to 35 mm², while control circuit connections accept 0.75 to 2.5 mm². Recommended tightening torques are 4 N·m for the main circuit and 1.2 N·m for the control circuit; ensure correct wire stripping lengths of 16 mm (main) and 10 mm (control).
For AC-1 operation at 690 V, Ie is 100 A at 40 °C, 80 A at 60 °C, and 70 A at 70 °C. For AC-3, ratings vary by voltage: 53 A at 415 V (60 °C), 53 A at 440 V (60 °C), 45 A at 500 V (60 °C), 35 A at 690 V (60 °C), with 53 A at 220–240 V. These values support motor and pump control with reliable switching.
Yes. The 4P NO configuration with 4 main contacts provides robust motor control capability for AC-1 and AC-3 loads. Its AC-3 ratings align with motor starting and running duties, while its compact DIN-rail footprint and accessory extendability help streamline panel design for conveyors, packaging equipment, and automated handling lines.
The device adheres to IEC/EN 60947-1 and IEC/EN 60947-4-1, with UL 60947-1 and UL 60947-4-1, CSA equivalents, and CE/UKCA declarations. Additional certificates include BV, CB, CCC, DNV, and RINA where applicable, reflecting broad regulatory compliance for global manufacturing and deployment.
Yes. The AFC family design enables easy extension with add-on auxiliary contact blocks and a wide range of accessories, allowing tailored control circuit configurations. This is ideal for applications requiring monitoring, interlock, or signaling circuits, while maintaining a compact footprint and consistent mounting compatibility.