ABB 1SBL361201R8600 Block Contactor - IEC/EN 60947-4-1

Part Number: 1SBL361201R8600
Manufacturer
ABB
Part number
1SBL361201R8600

Quick Summary

Block Contactor ABB 1SBL361201R8600 is a reliable 4-pole power switch designed to control AC power circuits in industrial automation and machine control. This model helps mitigate common control-panel failures by offering a robust, modular platform that supports easy expansion with auxiliary blocks. The device adheres to key global standards, including CE and UKCA declarations, and UL/CSA listings, with additional BV and RINA certifications for diverse markets. Its compact footprint and flexible mounting options translate into lower panel depth, easier maintenance, and improved lifecycle costs, while maintaining safe operation in harsh environments. For engineers seeking durability, compliance, and measurable efficiency gains, this contactor aligns with mid- to high-capacity control needs in modern factories.

Product Information

Extended Description

1SBL361201R8600 ABB: The AFC52-40-00-86 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 100 A (IEC AC-1) or 80 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 415 ... 440 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm² | Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523023437
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 4-pole main contacts NO configuration provides uncompromised power switching for 4-wire circuits. Benefit: Simplifies motor control and reduces component count, lowering panel complexity and wiring time. Application: Conveyor drives and pump assemblies where reliable AC-1/AC-3 switching is required. Feature: Coil voltage range 400…415 V AC at 50 Hz and 415…440 V AC at 60 Hz. Benefit: Direct compatibility with common European and North American control supplies, minimizing intermediate relays. Application: Control circuits in mixed-voltage production lines without extra transformers. Feature: Rated Operational Current AC-1 up to 100 A (690 V) and 80 A at 60 °C. Benefit: Clear capability for general use power switching with predictable thermal performance. Application: Machine tools and industrial equipment demanding robust on/off control. Feature: DIN-rail and screw mounting options TH35-15/TH35-7.5 plus diagonal screw mounting. Benefit: Flexible installation in compact control cabinets, reducing mounting time and enabling retrofits. Application: New installations and panel refurbishments in panel-building projects. Feature: Add-on auxiliary contact blocks and wide accessory range. Benefit: Scales control logic, interlocking, and signaling without replacing the base unit. Application: Safety circuits, interlocks, and machine status feedback in automated lines. Feature: Low power loss per pole with coil consumption: holding 20 V·A (50/60 Hz); pull-in ~150–151 V·A. Benefit: Lower heat generation and energy use in high-cycle applications, improving reliability and running costs. Application: Continuous operation in high-cycle conveyors and feeders. Feature: IP20 and IP10 protection ratings (coil and main terminals in compliance). Benefit: Safe operation inside standard enclosures with straightforward installation. Application: Industrial control panels with standard environmental exposure.

Get a Quick Quote for a ABB 1SBL361201R8600

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL361201R8600? Enquire Now

FAQs

ABB 1SBL361201R8600 supports TH35-15 and TH35-7.5 DIN rails, and it can be mounted using 2 x M4 or 2 x M6 screws placed diagonally. This provides flexible installation in compact control cabinets and simplifies retrofits. For panel builders, this means faster assembly and consistent alignment with other AFC contactors.
The device features 4 main NO contacts and operates with a main circuit rated up to 690 V. It handles AC-1 currents up to 100 A (ambient 40 °C) and AC-3 currents up to 53 A at 415–440 V, with a comprehensive impedance and switching profile suitable for motor loads and general-purpose control in automation.
Yes. The ABB AFC series, including 1SBL361201R8600, is listed for UL/CSA with a main circuit rating of up to 600 V and a general-use rating of 80 A. It also carries CE and UKCA declarations, supporting global compliance for electrical installations in North America and beyond.
The coil operates at 50 Hz 400–415 V and 60 Hz 415–440 V. Coil consumption includes an average holding value of 20 V·A (50/60 Hz) and pull-in values around 150–151 V·A. This yields reliable actuation with moderate energy use, beneficial for high-cycle applications with energy-aware design.
Its modular AF platform allows easy extension with auxiliary contact blocks, reducing the need for separate control relays. The low per-pole power loss minimizes heat and energy costs, while wide compatibility with accessories enables straightforward interlocking and signaling configurations, supporting long life cycles in demanding manufacturing environments.