ABB 1SBL361201R8800 Block Contactor - 4P 690V IEC/UL
Part Number: 1SBL361201R8800
Quick Summary
Block Contactor ABB 1SBL361201R8800 provides reliable AC switching for motor control and general power circuits in industrial equipment. Engineers often encounter space constraints, thermal management challenges, and the need for quick field upgrades; this device addresses those pains with a compact 4-pole design and screw terminals for robust wiring. It carries IEC/EN 60947-1 and 60947-4-1 compliance, UL and CSA listings, and CE/UKCA declarations, supporting global regulatory requirements. With DIN rail mounting and add-on contact blocks, it delivers installation efficiency, reduced wiring time, and long-term reliability for panel builders and OEMs.
Product Information
Extended Description
1SBL361201R8800 ABB: The AFC52-40-00-88 is a 4-pole (4 N.O) - 690 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 100 A (IEC AC-1) or 80 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 240 ... 260 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
113.5 mm
Product Net Weight
1.18 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 0 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 150 V·A | Average Pull-in Value 60 Hz 151 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time
Between Coil De-energization and NO Contact Opening 4 ... 14 ms | Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid 1/2x 6 ... 3 5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 6.5 | Main Circuit Slot | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 3 A | (200 ... 208 V AC) Three Phase 15 A | (220 ... 240 V AC) Three Phase 20 A | (240 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 50 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC40, AFC52, AFC65 3 or 4-pole contactors
CCC Certificate
CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
CQC Certificate
CQC Certificate, Contactor, AF40, AF52, AF65, AFC40, AFC52, AFC65, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
3471523019331
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
4-pole Block Contactor design enables solid power switching for motor loads and are rated for up to 100 A IEC AC-1 and 53 A AC-3, depending on thermal conditions. This translates into fewer devices in control panels and reduced wiring complexity, making it ideal for medium-to-high-power drives. Secure wiring is ensured by screw terminals designed for flexible ferrule and rigid conductors up to 35 mm²; this simplifies field installation and minimizes terminal torque-related faults. Coil control voltage options cover 50 Hz 230–240 V and 60 Hz 240–260 V, with coil consumption around 20 V·A holding and 150/151 V·A pull-in values. Power loss is kept low at 6.3 W per pole in AC‑1 service and 1.7 W in AC‑3, contributing to cooler operation and lower running costs. Operate times are tight, with 4–14 ms from coil de-energization to NO opening and 7–21 ms from energization to NO closing, minimizing arcing and wear. With a maximum mechanical switching frequency of 3600 cycles per hour, it supports demanding cycle rates in conveyors and packaging lines. Mounting and compatibility: DIN rail TH35-15; 2x M4 or 2x M6 screws for panel mounting; block design easily extended with add-on auxiliary blocks and accessories. Compliance and environment: rated insulation voltage 690 V; main terminals IP10, coil terminals IP20; ambient -40 to 70 C; altitude up to 3000 m; RoHS/REACH; WEEE B2B.
Get a Quick Quote for a ABB 1SBL361201R8800
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL361201R8800?
Enquire Now
FAQs
ABB 1SBL361201R8800 supports DIN rail mounting using TH35-15 standards and also offers screw mounting options (2x M4 or 2x M6) for panel installation. It features screw terminals for main and control circuits, with a compact footprint (70 mm width, 119.5 mm depth, 113.5 mm height) to simplify panel layout and future expansion with add-on auxiliary blocks.
For AC-1, the Contactor handles up to 100 A at 40 °C, 80 A at 60 °C, and 70 A at 70 °C. For AC-3, ratings are 53 A across typical 415–690 V ranges. These figures align with IEC 60947-4-1 and support motor control and general switching in industrial panels.
Yes. The ABB 1SBL361201R8800 complies with IEC/EN 60947-1 and 60947-4-1, and is UL/CSA listed with CE and UKCA declarations, ensuring compliance for global deployment in industrial control panels and OEM applications.
Maximum breaking capacity is 950 A at 440 V (cos φ 0.45) and 600 A at 690 V (cos φ 0.45). Insulation voltage Ui is 690 V, with main terminals rated IP10 and auxiliary/coil terminals IP20, meeting standard industrial protection requirements.
Coil consumption ranges include 20 V·A holding and 150–151 V·A pull-in, with power losses of 6.3 W per pole (AC-1) and 1.7 W (AC-3). Lower coil energy translates to reduced heat in panels, longer contactor life, and lower running costs in continuous-duty or high-cycle applications.