ABB 1SBL367001R1100 Contactor - AF Tech, 24-60 VAC/DC

Part Number: 1SBL367001R1100
Manufacturer
ABB
Part number
1SBL367001R1100

Quick Summary

ABB 1SBL367001R1100 Contactor is a 3-pole motor starter used to control industrial motors on conveyors and manufacturing lines. Fluctuating control voltages and panel energy waste can compromise reliability; AF technology tolerates wide voltage swings, reducing misoperation and rework in unstable networks. This model supports common standards such as CE marking, IP-rated enclosures, and SIL-compatible control logic, enabling safer, regionally compliant installations. With built‑in surge protection and a compact block design, it minimizes panel space and wiring complexity. Its screw terminals and extensible auxiliary contact blocks simplify installation and future expansion, helping facilities lower energy use, cut maintenance costs, and improve overall line uptime.

Product Information

Extended Description

1SBL367001R1100 ABB: The AF52-30-00-11 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) or 40 hp / 480 V UL and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRAPR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHNOR001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CLABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CNIAB001EXPU
Storage Location
4001
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
COABB001EXPU
Storage Location
4001
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DEAPRMLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DKSER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
DUABB003EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EESER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
EGAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ESATD001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Lead Time
14 day
Country of Origin
France (FR)
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FISER001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
FRAUT001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GBINS001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
GRABB001EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABBRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ITIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NLABB021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
NOATDRLCEXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
SGIND002EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
TRDMD001EXPU
Storage Location
4001
Country of Origin
France (FR)
Criticality
No
Lead Time
14 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USABB251EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Lead Time
35 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USSVCEXPU
Warranty Return
Product under warranty must be returned
Configuration Only
No
Country of Origin
France (FR)
Criticality
No
Lead Time
0 day
Made To Order
No
Note
No
Product Availability Class
Standard delivery time
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
ZATAD021EXPU
Storage Location
4001
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
55 mm
Product Net Depth / Length
111 mm
Product Net Height
125.5 mm
Product Net Weight
0.97 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 100 A | (110 V) 2 Poles in Series, 60 °C 80 A | (110 V) 2 Poles in Series, 70 °C 70 A | (110 V) 3 Poles in Series, 40 °C 100 A | (110 V) 3 Poles in Series, 60 °C 80 A | (110 V) 3 Poles in Series, 70 °C 70 A | (220 V) 3 Poles in Series, 40 °C 100 A | (220 V) 3 Poles in Series, 60 °C 80 A | (220 V) 3 Poles in Series, 70 °C 70 A | (72 V) 1-Pole, 40 °C 100 A | (72 V) 1-Pole, 60 °C 80 A | (72 V) 1-Pole, 70 °C 70 A | (72 V) 2 Poles in Series, 40 °C 100 A | (72 V) 2 Poles in Series, 60 °C 80 A | (72 V) 2 Poles in Series, 70 °C 70 A | (72 V) 3 Poles in Series, 40 °C 100 A | (72 V) 3 Poles in Series, 60 °C 80 A | (72 V) 3 Poles in Series, 70 °C 70 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 100 A | (110 V) 2 Poles in Series, 60 °C 80 A | (110 V) 2 Poles in Series, 70 °C 70 A | (110 V) 3 Poles in Series, 40 °C 100 A | (110 V) 3 Poles in Series, 60 °C 80 A | (110 V) 3 Poles in Series, 70 °C 70 A | (220 V) 3 Poles in Series, 40 °C 100 A | (220 V) 3 Poles in Series, 60 °C 80 A | (220 V) 3 Poles in Series, 70 °C 70 A | (72 V) 1-Pole, 40 °C 100 A | (72 V) 1-Pole, 60 °C 80 A | (72 V) 1-Pole, 70 °C 70 A | (72 V) 2 Poles in Series, 40 °C 100 A | (72 V) 2 Poles in Series, 60 °C 80 A | (72 V) 2 Poles in Series, 70 °C 70 A | (72 V) 3 Poles in Series, 40 °C 100 A | (72 V) 3 Poles in Series, 60 °C 80 A | (72 V) 3 Poles in Series, 70 °C 70 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 100 A | (110 V) 2 Poles in Series, 60 °C 80 A | (110 V) 2 Poles in Series, 70 °C 70 A | (110 V) 3 Poles in Series, 40 °C 100 A | (110 V) 3 Poles in Series, 60 °C 80 A | (110 V) 3 Poles in Series, 70 °C 70 A | (220 V) 3 Poles in Series, 40 °C 100 A | (220 V) 3 Poles in Series, 60 °C 80 A | (220 V) 3 Poles in Series, 70 °C 70 A | (72 V) 1-Pole, 40 °C 100 A | (72 V) 1-Pole, 60 °C 80 A | (72 V) 1-Pole, 70 °C 70 A | (72 V) 2 Poles in Series, 40 °C 100 A | (72 V) 2 Poles in Series, 60 °C 80 A | (72 V) 2 Poles in Series, 70 °C 70 A | (72 V) 3 Poles in Series, 40 °C 100 A | (72 V) 3 Poles in Series, 60 °C 80 A | (72 V) 3 Poles in Series, 70 °C 70 A
Rated Operational Power AC-3 (Pe)
(400 V) 22 kW | (415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Operational Power AC-3e (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value 50 Hz 4 V·A | Average Holding Value 60 Hz 4 V·A | Average Holding Value DC 2 W | Average Holding Value, from Warm State 2 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 17 ... 100 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3 hp | (200 ... 208 V AC) Three Phase 15 hp | (220 ... 240 V AC) Three Phase 20 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 40 hp | (550 ... 600 V AC) Three Phase 50 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 34 A | (200 ... 208 V AC) Three Phase 48.3 A | (220 ... 240 V AC) Three Phase 54 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 52 A | (550 ... 600 V AC) Three Phase 52 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 g | Closed, Shock Direction: B1 25 g | Closed, Shock Direction: B2 15 g | Closed, Shock Direction: C1 25 g | Closed, Shock Direction: C2 25 g | Open, Shock Direction: B1 5 g
Resistance to Vibrations
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
71c82dcf-217b-416b-9985-2f7ef9946893 France (FR)
Simplified SCIP
d7b62b42-47ae-4d94-87de-e93def0da041 Poland (PL) | f5d8d1fc-8bf8-48c5-bfdb-20cef1721db8 Belgium (BE) | 41d365b9-6787-41d9-8e0e-bc7c12f402f2 Norway (NO) | 1b310530-6a78-45e8-9afb-ec052a4c4935 Germany (DE) | 94f6a63c-786b-43d1-99a4-941a55113656 Poland (PL) | 9a382b80-274b-482a-93d3-78f69d135dbd Netherlands (NL) | c2c5f2f9-f229-4952-942b-6dc8c6686ea8 Hungary (HU) | bb467480-aa41-4817-8b2d-d219427d26de Estonia (EE) | f672d4df-567d-4a50-adfb-77fa1693f2cd Greece (GR) | 9c59f024-1b55-4c7f-954c-8069a5511e6f Portugal (PT) | f14d220e-aef9-42d8-8bcc-03bc58528a3c Spain (ES) | 283406d6-c2df-46a1-91f0-c230e668b4fa Finland (FI) | 056ea954-00c9-48e4-be35-dbfc3ee687e9 Belgium (BE) | 8fd7c910-fbcf-49c0-a561-ead5ab5f2862 Italy (IT) | 49825151-4c01-427e-a00b-7698594088f2 Denmark (DK) | 68adf577-1672-4d1a-a553-3642ad614362 Germany (DE) | 910d0247-288e-4a17-aa0f-b5021552b469 Croatia (HR) | c5ba9d4c-04f6-4739-8eb5-ecdad7caad65 Czech Republic (CZ) | 52029c19-84ef-4600-86e1-d3cfc82ecb72 Bulgaria (BG) | 4e18e19e-8a6d-4c84-9311-779c3b7f88da Sweden (SE) | 51a03e87-9ce8-4b45-8554-4515476bd870 Poland (PL) | cfc6ba7f-17d5-482a-9a9f-01fd3ef91047 France (FR) | 274ec7be-1bb8-40e9-ba0a-a941c7477ff5 Sweden (SE) | e8814343-5757-4823-818c-3235209edffc Germany (DE) | 552e7560-16eb-44ad-922b-e4b9fda30832 Germany (DE) | 6b4ebdff-859b-4e97-86f3-2dbcd41a3a5b Hungary (HU) | 5bc2e6a1-266c-40c8-b71c-ee13c6cdf12c Germany (DE)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF40, AF52, AF65 (CN) | Environmental Product Declaration AF(S)40(B), AF(S)52(B), AF(S)65(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
CQC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France | CQC Certificate, Contactor, AF40, AF52, AF65, AFC40, AFC52, AFC65, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France | CCC Declaration of Conformity, Contactor, AF(C)40, AF52(C), AF65(C),AFC78 Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09... AF96-30-.., AF09...38(Z)-30..K 3-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
KC Certificate
KC Certificate AF52 3-pole Contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RINA Certificate
Rina Certificate for AF09...AF96 contactors, NF contactor relays and accessories, screw and spring terminals
RMRS Certificate
RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
UL Listing Card
UL_E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
97 mm
Package Level 1 Gross Weight
1.07 kg
Package Level 1 EAN
3471523132313
Package Level 2 Units
box 10 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
10.7 kg
Package Level 3 Units
240 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707014
E-Number (Sweden)
3210037
Feature AF technology delivers a wide control voltage range (24-60 V AC, 50/60 Hz, and 20-60 V DC) which translates to reduced wiring variations and fewer panel redesigns during voltage fluctuations. Benefit Lower energy consumption and improved reliability in unstable networks. Application Ideal for automated lines and machinery where supply stability varies. Feature 3-pole design with ratings up to 690 V IEC or 600 V UL supports robust motor control across regions. Benefit Enables direct switching of motors up to 22 kW at 400 V AC (AC-3) or 40 hp at 480 V UL, reducing components and simplifying wiring. Application Conveyor systems, machine tools, and processing equipment.Feature Built-in surge protection and screw terminals simplify wiring and safeguard circuits. Benefit Reduces need for external protection devices and speeds installation. Application Panel assemblies in harsh environments where transients occur.Feature Block-type AF contour with easy extension via add-on auxiliary contact blocks. Benefit Streamlines future expansion and maintenance, lowering lifecycle costs. Application Modular control of evolving lines and added safety interlocks.Feature Compact, space-efficient construction with a wide accessory ecosystem. Benefit Improves panel density, lowers enclosure footprint, and supports scalable automation. Application Retrofit projects and new machine builds requiring compact, upgrade-friendly contactors.

Get a Quick Quote for a ABB 1SBL367001R1100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL367001R1100? Enquire Now

FAQs

The 1SBL367001R1100 uses screw terminals for straightforward, reliable wiring and is designed as a 3-pole motor starter. Its compact block-type form factor is compatible with standard DIN rail and panel mounting approaches, and it supports add-on auxiliary contact blocks to expand signaling without complicating the base installation.
Key ratings include 3-pole construction with voltage ratings up to 690 V AC (IEC) or 600 V UL, control voltage range of 24-60 V AC (50/60 Hz) and 20-60 V DC, and load capabilities up to 22 kW at 400 V AC (AC-3) or 40 hp at 480 V UL. Current handling reaches up to 100 A AC-1, or 80 A UL, making it suitable for standard motor control tasks.
This AF technology contactor excels in conveyors, machine tools, and processing lines where motor start/stop control occurs under variable voltage conditions. Its wide control voltage tolerance, built-in surge protection, and compatibility with auxiliary blocks make it ideal for compact, energy-efficient automation cabinets and upgrade projects.
The device is designed to align with industry-standard safety and performance expectations, including CE-marking and common IP-rated enclosure practices, alongside SIL-compatible control logic. These attributes support safe integration in regional automation systems and help meet regulatory requirements in diverse manufacturing environments.
AF technology tolerates large control voltage variations, reducing wear and misoperation from supply fluctuations. Built-in surge protection lowers external accessory needs, while screw terminals and modular auxiliary blocks simplify commissioning and future upgrades. The result is lower maintenance costs, improved uptime, and a faster return on investment for automated lines.