ABB 1SBL367201R1300 Block Contactor - 690V IEC
Part Number: 1SBL367201R1300
Quick Summary
ABB 1SBL367201R1300 is a block contactor used for reliable motor control in industrial panels. It helps protect equipment from voltage fluctuations and reduces energy waste by supporting a wide control voltage range. This device carries IEC/EN 60947-1 and 60947-4-1 certifications, along with UL 60335-2-40, and features IP20 coil protection for safer operation. Its modular design enables easy expansion with auxiliary blocks and compatible DIN-rail mounting, delivering scalable performance for conveyors, pumps, and machine tools. For engineers and procurement teams, it combines robust electrical ratings with straightforward installation, helping to streamline compliance and maintenance while delivering predictable, long-term uptime.
Product Information
Extended Description
1SBL367201R1300 ABB: The AF52-40-00-13 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
113.5 mm
Product Net Height
125.5 mm
Product Net Weight
1.16 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value 50 Hz 4 V·A | Average Holding Value 60 Hz 4 V·A | Average Holding Value DC 2 W | Average Holding Value, from Warm State 2 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.3 W | at Rated Operating Conditions AC-3 per Pole 1.7 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 80 A
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 3 A | (200 ... 208 V AC) Three Phase 15 A | (220 ... 240 V AC) Three Phase 20 A | (240 V AC) Single Phase 10 A | (440 ... 480 V AC) Three Phase 40 A | (550 ... 600 V AC) Three Phase 50 A
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations
3g Closed Position & 2g Open Position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
6eea65c8-5f94-47c5-99d5-be4670b5a8ac France (FR)
Simplified SCIP
9be8b062-dbca-49ee-897e-9f800b4e301f Germany (DE) | 595a5625-2fce-4b28-8cd9-ec6e496adb12 Norway (NO) | 3b66d278-56f5-4e8b-aafc-f9da2ab6e748 Hungary (HU) | 06e45964-c279-4267-ad46-b43d299fa327 Estonia (EE) | 88c281b6-f549-4257-b4f5-d91d5d13b827 Greece (GR) | d5f8634c-ab38-475d-bbe1-dcb93fb0fee0 Portugal (PT) | 044d79b6-9de4-4a4e-bb6a-c8aa1833cff6 Bulgaria (BG) | 68a55a60-0586-498f-919d-84512d164d7d Poland (PL) | 3aa67de6-8e57-4342-9d85-4e21bce99cc9 Belgium (BE) | fb45f20c-361c-4c78-889f-12591fbdc846 Germany (DE) | b128d632-d83d-4cd3-a401-bb6c37370d79 Hungary (HU) | fe6fe32e-b8be-4258-9e82-922b6630c4fa Spain (ES) | f4eccf12-935e-4f8a-bbe7-5067954b2d8c Finland (FI) | d8242696-1b79-40a0-9761-1f66152866e2 Belgium (BE) | 093f7b7b-e9cb-4e6b-a798-0164f4427ebf Italy (IT) | c3eda9e0-7d8e-42e4-b43c-2e65fea6ed82 Germany (DE) | 5d300b9d-2b4f-4881-b46b-cf104fc9655b Denmark (DK) | 47fa390f-1033-4bf8-bf92-cbb0dade84bf Germany (DE) | 16ff3c0e-52c6-4cd8-94e8-7cdbf1cb196b Croatia (HR) | d7cc5d00-24bc-41c7-86c5-70fa887fcca9 Czech Republic (CZ) | 102ac3a1-dab2-4a53-b91c-82abd36840ef Poland (PL) | 170b1373-1d48-4e0a-9b8e-eb4c6a3aa63f Netherlands (NL) | ba55232b-fc3f-4aed-81c4-47f3167ea6f8 Sweden (SE) | 580004b1-0a7a-463e-b192-eacdb4d9b7dc Poland (PL) | 93d28930-4246-4f43-b946-483b03b119e2 France (FR) | 80d3df0e-6bd3-46db-bfe1-9c0bc77d4b66 Sweden (SE) | 2848fad5-b957-41d5-a16f-739dea097d3b Germany (DE)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF40, AF52, AF65 (CN) | Environmental Product Declaration AF(S)40(B), AF(S)52(B), AF(S)65(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
CQC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
KC Certificate
KC Certificate AF52 4-pole Contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RMRS Certificate
RMRS Certificate AF09(S)...AF38 3-pole and 4-pole, AF40..96 3-pole contactors, screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AF40(B)...80(B) 4-pole contactors | UL-CA Certificate of Compliance AF40(B)...80(B) 4-pole contactors
UL Listing Card
UL_E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.27 kg
Package Level 1 EAN
3471523133631
Package Level 2 Units
box 8 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
10.16 kg
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707262
E-Number (Sweden)
3210311
Feature AF technology offers a wide control voltage range of 100-250 VAC or DC, reducing panel energy fluctuations and enabling stable control in networks with varying supply quality. Business Impact Lower energy consumption in control circuits and less panel heat generation, which translates to reduced cooling costs and improved overall efficiency. Application Suitable for AC-3 motor control up to 22 kW at 400 V and AC-1 up to 100 A at 690 V, making it ideal for fans, pumps, and conveying systems in manufacturing environments. Feature Built-in surge protection protects the coil and contact set from voltage spikes, increasing reliability in harsh electrical environments. Business Impact Fewer unexpected outages and extended equipment life, with reduced maintenance and replacement costs. Application Particularly valuable in systems with long cable runs or intermittent power quality issues. Feature 4-pole block design with screw terminals and 70 mm width (DIN rail TH35-15 compatibility) supports compact panel layouts and straightforward wiring. Business Impact Saves panel space and accelerates installation, lowering commissioning time and labor costs. Application Suitable for tight control cabinets and retrofit projects where space is limited. Feature Wide operating voltage tolerance and latch-free coil current (4 V·A holding, DC 2 W holding) provide robust performance across temperatures. Business Impact Improves switch reliability and reduces energy waste during standby, contributing to longer coil life and lower operating costs. Application Ideal for systems with variable loads and diverse supply conditions in food & beverage, packaging, and process industries. Feature Compliance with IEC/EN 60947-4-1, UL 60335-2-40, and CSA standards ensures regulatory alignment across global plants. Business Impact Simplifies global procurement and minimizes risk during audits and certifications. Application Supports multinational deployments and cross-site standardization. Feature Compatibility with add-on auxiliary contact blocks and other accessories enables scalable control solutions. Business Impact Enables phased upgrades and extended functionality without replacing the base device. Application Useful for future-proofing panels in aging lines or expanding automation scope.
Get a Quick Quote for a ABB 1SBL367201R1300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL367201R1300?
Enquire Now
FAQs
Install on a standard TH35-15 DIN rail with the coil terminals facing the front for easy wiring. Secure the device with mounting clips and tighten main circuit and control circuit connections to the recommended torque. Use appropriate ferrule terminations and ensure the panel supports 690 V insulation levels. This setup favors quick replacements and consistent torque across all connections.
Main circuit rated 690 V with AC-1 current up to 100 A at 40 °C and 80 A at 60 °C; AC-3 current up to 53 A across 415–690 V. The device supports 100–250 V control voltage (AC or DC) and offers 6 kV impulse withstand voltage, enabling robust motor control in diverse industrial environments.
Yes. The AF technology block contactors are designed for easy extension with add-on auxiliary contact blocks, enabling customized signaling and interlock schemes without replacing the base unit. This makes upgrades straightforward in evolving automation projects and helps maintain consistent control logic across lines.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, CSA equivalents, and supporting certifications such as UL/CSA listing, DNV, and additional regional approvals. This mix supports global deployments and simplifies regulatory audits in manufacturing facilities.
AF technology provides a broad control voltage tolerance, reducing energy waste from control circuits and improving panel energy efficiency. In addition, built-in surge protection reduces downtime from spikes, extending coil life and lowering maintenance costs. Across a plant, these factors translate to lower operating expenses and higher uptime containment.