ABB 1SBL367561R1100 Block Contactor - 690 V IEC/UL
Part Number: 1SBL367561R1100
Quick Summary
The 1SBL367561R1100 block contactor from ABB provides reliable motor control in 690 V AC networks. It is designed to cope with wide control voltage variations, helping to reduce panel energy waste and minimize downtime in demanding drive applications. This device complies with key safety and performance standards such as IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60335-2-40 (CSA variants also referenced), ensuring safe operation across global installations. Built with AF technology, it supports easy expansion with auxiliary contact blocks while maintaining a compact footprint. For engineers and procurement teams, the combination of robust electrical ratings and a scalable accessory ecosystem delivers tangible operational and cost benefits over the lifecycle of a panel-wide motor control solution.
Product Information
Extended Description
1SBL367561R1100 ABB: The AF52B-22-00-11 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
Motor control and protection for Rolling stock application_PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
113.5 mm
Product Net Height
125.5 mm
Product Net Weight
1.21 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 100 A | (690 V) 60 °C 80 A | (690 V) 70 °C 70 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 53 A | (440 V) 60 °C 53 A | (500 V) 60 °C 45 A | (690 V) 60 °C 35 A | (380 / 400 V) 60 °C 53 A | (220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)
(415 V) 30 kW | (440 V) 30 kW | (500 V) 30 kW | (690 V) 30 kW | (380 / 400 V) 22 kW | (220 / 230 / 240 V) 15 kW
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value DC 2 W
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Shock and Vibration Withstand acc. to IEC 61373
Category 1, Class B
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)40(B), AF(S)52(B), AF(S)65(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09 ... AF38(Z)B..(K), AF40B ... AF96B 3 and 4-pole contactors
UL Certificate
UL-US Certificate of Compliance AF40(B)...80(B) 4-pole contactors | UL-CA Certificate of Compliance AF40(B)...80(B) 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.32 kg
Package Level 1 EAN
3471523025080
Package Level 2 Units
box 8 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
10.56 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
AF technology enables a wide control voltage range, reducing control circuit stress and enabling stable operation in networks with voltage fluctuations. This translates into lower energy consumption in control circuits and fewer nuisance trips in unstable mains while maintaining reliable motor start-up. The 4-pole, 690 V contactor delivers up to 100 A AC-1 and 53 A AC-3, supporting motor control up to 22 kW at 380/400 V or 30 kW at higher line voltages, which directly improves drive efficiency and reduces wiring complexity in motor starter panels. Built-in surge protection eliminates the need for external snubbers in many installations, cutting BOM costs and simplifying maintenance. Screw terminals provide secure, vibration-resistant connections suitable for demanding industrial environments. The block design is easily expandable with add-on auxiliary contact blocks, enabling flexible control schemes and future-proofing for evolving automation requirements. With compact dimensions (70 mm width, 113.5 mm depth, 125.5 mm height) and a weight of 1.21 kg, it fits tightly in tight control enclosures while delivering high current capability. Compatibility with standard accessories and compliance documentation supports fast installation and regulatory acceptance, helping to shorten project timelines and improve total cost of ownership.
Get a Quick Quote for a ABB 1SBL367561R1100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL367561R1100?
Enquire Now
FAQs
To install the 1SBL367561R1100, mount the unit in a suitable enclosure and connect the main power and coil wiring to the screw terminals as per the IEC/EN 60947-1 guidelines. Ensure coil voltage matches 24–60 V AC or 20–60 V DC, and use compatible auxiliary contact blocks if expansion is required. Verify torque and secure all connections to avoid vibration-related loosening in harsh environments. The device supports straightforward integration with AF accessories for scalable control configurations.
The coil voltage range is 24 to 60 V for AC operation (50/60 Hz) and 20 to 60 V for DC operation. Coil consumption is 4 VA at 50/60 Hz and 2 W for DC holding. These values enable efficient control while accommodating variations in control voltage without sacrificing performance or increasing heat in the control panel.
Yes. At 380/400 V, the contactor provides 53 A (AC-3) and up to 22 kW (AC-3) for that voltage class, with 60 °C ratings. It remains fully capable of switching typical AC-3 duty loads, such as pumps and fans, while maintaining adequate insulation and protection. For higher line voltages, the device supports 30 kW (AC-3) up to 690 V, offering flexibility across a range of motor sizes.
The product aligns with IEC/EN 60947-1 and IEC/EN 60947-4-1 for general and motor-contactor requirements, and UL 60335-2-40 as well as CSA equivalents for appliance safety. These certifications ensure safe operation in global markets and facilitate compliance during system integration and regulatory reviews.
AF technology stabilizes control voltage and reduces energy waste in the control circuit, lowering operating costs over the system’s life. Built-in surge protection minimizes external protection components, reducing maintenance and spare parts. The compact, modular block design with add-on contact blocks enables scalable control architectures, supporting future upgrades without major rewiring, which translates to lower total cost of ownership and faster deployment in new or expanding automation projects.