ABB 1SBL371074R8111 Block Contactor - CE Conformity
Part Number: 1SBL371074R8111
Quick Summary
ABB 1SBL371074R8111 Block Contactor is a 3-pole device that switches three-phase motors up to 690 V AC using a 24 V control coil. For engineers upgrading panels, space constraints and wiring complexity can slow deployment. With CE conformity, UL/CSA safety recognition, and CB certification, this ABB contactor supports global compliance and traceability. Designed for reliability and easy integration, it helps panel builders reduce footprint while maintaining robust motor control for automation lines, conveyors, and pumps in manufacturing environments. The compact 82 mm width and 108 mm height support dense control panels, while its accessible accessory ecosystem simplifies installation.
Product Information
Extended Description
1SBL371074R8111 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 95 A | (690 V) 40 °C 115 A | (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 65 A | (440 V) 55 °C 65 A | (500 V) 55 °C 55 A | (690 V) 55 °C 43 A | (380 / 400 V) 55 °C 65 A | (220 / 230 / 240 V) 55 °C 65 A
Rated Operational Power AC-3 (Pe)
(415 V) 37 kW | (440 V) 37 kW | (500 V) 37 kW | (690 V) 37 kW | (380 / 400 V) 30 kW | (220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.5 W | at Rated Operating Conditions AC-3 per Pole 1.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 90 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 5 hp | (200 ... 208 V AC) Three Phase 20 hp | (220 ... 240 V AC) Three Phase 25 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 56 A | (200 ... 208 V AC) Three Phase 62.1 A | (220 ... 240 V AC) Three Phase 68 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522406811
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Three main normally open contacts plus one normally open auxiliary contact streamline motor control topology, reducing wiring complexity and enabling straightforward interlocking for conveyors and pumps. The design supports add-on auxiliary contact blocks for side mounting and a wide range of accessories, delivering flexible installation in limited spaces. Rated for main circuits up to 690 V and auxiliary circuits up to 690 V, it enables reliable control of high-voltage drives with lower panel footprint and fewer components, cutting both capex and assembly time. Coil voltage of 24 V at 50/60 Hz aligns with common control circuits, while coil power loss of 6.5 W per pole (AC-1) and 1.5 W per pole (AC-3) reduces heat and energy consumption in continuous operation. Mechanical and electrical endurance, along with IP20 coil terminals and IP10 main terminals, support rugged industrial environments. Compatibility with CAD drawings, 2D and 3D files, and AX50–AX80 accessories facilitates rapid design-in and seamless installation.
Get a Quick Quote for a ABB 1SBL371074R8111
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL371074R8111?
Enquire Now
FAQs
Yes. The 1SBL371074R8111 is a 3-pole block contactor designed for 24 V control and 690 V mains, compatible with add-on auxiliary blocks for side mounting and a wide accessory range. Use screw terminals for secure wiring and adhere to the tightening torques of 1 N·m on the control circuit and 4 N·m on the main circuit. For CAD-enabled design, download the 2D/3D files and ensure panel space and clearance meet IEC requirements.
At 690 V, the rated operational current is 115 A (AC-1) and 43 A (AC-3). Maximum breaking capacity is 1300 A at cos phi 0.45 (for 440 V) and 630 A at 690 V, with reduced values for higher power factor scenarios. The device also provides a high short-time withstand current per IEC ratings, ensuring it can tolerate motor start surges typical in heavy loads.
Yes. The 3 NO main contacts and 1 NO/1 NC auxiliary contact arrangement, combined with 24 V control and 690 V mains, makes it ideal for motor control in conveyors, pumps, and similar drive applications. Its compact footprint, IP ratings, and compatibility with standard 24 V control logic support reliable integration in machine panels and centralized control cabinets.
The product carries CE Declarations of Conformity and UL/CSA certifications, along with CCC and CQC certificates. It also lists CB certification and RoHS/REACH declarations, ensuring global compliance for electronics in industrial environments. This breadth of certifications helps simplify cross-border procurement and regulatory documentation.
Maintenance is straightforward due to screw-terminal design and robust construction. The contactor provides low coil power loss, reducing heat generation and energy use in continuous duty. The compact footprint lowers panel costs, while compatibility with CAD data accelerates commissioning. Overall, this translates to faster install times, lower wiring risk, and improved uptime for motor-driven lines.