ABB 1SBL371074R8400 Block Contactor - 690V CE/CB Certified

Part Number: 1SBL371074R8400
Manufacturer
ABB
Part number
1SBL371074R8400

Quick Summary

The ABB 1SBL371074R8400 block contactor is designed to reliably switch three-phase motors up to 690 V AC in industrial control applications. Engineers often face downtime and misapplication risk when selecting a contactor for varying voltages and duty cycles, which can drive up maintenance costs. This device carries CE conformity and CB certification for global compliance, plus RoHS/REACH declarations to meet modern environmental and safety standards. With its compact 3-pole footprint and compatibility with auxiliary contact blocks, it delivers straightforward installation and predictable long-term performance in control cabinets.

Product Information

Extended Description

1SBL371074R8400 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 95 A | (690 V) 40 °C 115 A | (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 65 A | (440 V) 55 °C 65 A | (500 V) 55 °C 55 A | (690 V) 55 °C 43 A | (380 / 400 V) 55 °C 65 A | (220 / 230 / 240 V) 55 °C 65 A
Rated Operational Power AC-3 (Pe)
(415 V) 37 kW | (440 V) 37 kW | (500 V) 37 kW | (690 V) 37 kW | (380 / 400 V) 30 kW | (220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.5 W | at Rated Operating Conditions AC-3 per Pole 1.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 90 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 5 hp | (200 ... 208 V AC) Three Phase 20 hp | (220 ... 240 V AC) Three Phase 25 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 56 A | (200 ... 208 V AC) Three Phase 62.1 A | (220 ... 240 V AC) Three Phase 68 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522405845
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707364
Feature: 3 main NO contacts and 690 V main circuit. Business Impact: Enables safe and efficient control of high-power three-phase motors with a generous current capability, reducing the need for oversized alternatives. Application: Suitable for conveyors, pumps, and fans in harsh industrial environments. Feature: 110 V control circuit at 50/60 Hz. Business Impact: Matches common plant control voltages, lowering miswiring risk and setup time. Application: Ideal for centralized control panels and machine assemblies. Feature: Ith 125 A; Ie up to 115 A at 690 V (70 °C) and 65 A at 415–690 V (55 °C). Business Impact: Provides ample headroom for peak motor loads, improving reliability and uptime. Application: Heavy-load start/stop in metalworking lines and material handling. Feature: Power loss 6.5 W per pole (AC-1) and 1.5 W per pole (AC-3). Business Impact: Reduces heat and energy consumption in panel backplanes, extending component life. Application: Continuous-duty motor control in energy-conscious installations. Feature: Product footprint 70 mm wide, 110 mm deep, 108 mm high; screw terminals; IP20 coil, IP10 main. Business Impact: Streamlined panel layout with easy wiring and maintenance, lowering installation time. Application: Compact cabinets and retrofit projects where space is at a premium. Feature: Optional add-on auxiliary contact blocks and wide accessory range. Business Impact: Scales with control complexity without replacing the base device, reducing total cost of ownership. Application: Customizable control schemes for packaging lines, compressors, and HVAC equipment.

Get a Quick Quote for a ABB 1SBL371074R8400

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL371074R8400? Enquire Now

FAQs

Install the device with three main NO contacts wired in series with the motor circuit and connect the coil terminals to the 110 V control supply (50/60 Hz). Tighten main terminals to 4 N·m and coil terminals to 1 N·m as specified, using screw terminals. Maintain proper clearance and ensure IP20 protection on the coil side to prevent dust ingress. Use the optional auxiliary contact blocks if the control logic requires feedback or interlocking. This setup minimizes startup transients and ensures reliable interlock behavior in automated lines.
Yes, it is designed for 690 V AC main circuits. The rated operational current for AC-3 is 43–65 A depending on voltage and temperature; for AC-1 operations it is 80–115 A depending on voltage and ambient temperature. This provides ample headroom for moderate to heavy motor loads, enabling reliable starting and switching without overheating under typical industrial duty cycles.
The device features CE conformity for European markets and CB certification for global electrical safety compliance. It is RoHS compliant with REACH declarations and supports CCC, CQC, SSD UL-related references for broader regulatory acceptance. This combination helps ensure that panel builders meet stringent regulatory requirements while simplifying cross-border procurement.
The block contactor has a compact footprint of 70 mm width, 110 mm depth, and 108 mm height, with screw terminals for all main and control connections. Coil terminals are rated IP20, and main terminals IP10, aiding safe operation inside control cabinets. Use the external accessory range to extend functionality, and ensure mounting spacing complies with standard enclosure layouts to facilitate servicing and future expansion.
The device delivers robust motor control with low power loss—6.5 W per pole for AC-1 and 1.5 W per pole for AC-3—reducing heat in the control panel and prolonging relay life. Its 3-pole 690 V capability and 110 V control voltage minimize downtime due to mis-wiring and mismatched components. Combined with CE/CB compliance and optional auxiliary blocks for expanded control logic, the contactor supports higher uptime and lower maintenance costs over the system lifecycle.