ABB 1SBL371074R8411 Block Contactor - CE/UL Certified

Part Number: 1SBL371074R8411
Manufacturer
ABB
Part number
1SBL371074R8411

Quick Summary

ABB 1SBL371074R8411 Block Contactor is a 3-pole AC-operated switch used to control 3-phase motors in industrial power circuits. Engineers often wrestle with coil voltage compatibility, mounting options, and reliable performance across varying voltages. CE and UL/CSA certifications ensure global compliance, while IP20 coil protection and IP10 main terminals enhance safe operation in control cabinets. This solution supports cross-regional deployment, offers compatibility with the AX50–AX80 family, and delivers predictable performance, reduced downtime, and a lower total cost of ownership in factory automation environments.

Product Information

Extended Description

1SBL371074R8411 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 95 A | (690 V) 40 °C 115 A | (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 65 A | (440 V) 55 °C 65 A | (500 V) 55 °C 55 A | (690 V) 55 °C 43 A | (380 / 400 V) 55 °C 65 A | (220 / 230 / 240 V) 55 °C 65 A
Rated Operational Power AC-3 (Pe)
(415 V) 37 kW | (440 V) 37 kW | (500 V) 37 kW | (690 V) 37 kW | (380 / 400 V) 30 kW | (220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 6.5 W | at Rated Operating Conditions AC-3 per Pole 1.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 90 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 5 hp | (200 ... 208 V AC) Three Phase 20 hp | (220 ... 240 V AC) Three Phase 25 hp | (240 V AC) Single Phase 10 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 56 A | (200 ... 208 V AC) Three Phase 62.1 A | (220 ... 240 V AC) Three Phase 68 A | (240 V AC) Single Phase 50 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522406842
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → 3 main NO contacts plus 1 NO and 1 NC auxiliary contact provide complete control of motor and circuit signals. Business Impact → Simplifies wiring, reduces panel space, and increases reliability by consolidating control and signaling in a single device. Application → Ideal for 3-phase motor control on conveyors, pumps, and fans in manufacturing settings. Feature → 110 V control circuit with AC operation and 50/60 Hz compatibility ensures seamless regional deployment. Business Impact → Eliminates voltage mismatches and minimizes inventory variety across plants. Application → Suitable for globally distributed automation deployments using 110 V control logic. Feature → Rated operational voltage up to 690 V and insulation voltage 690 V. Business Impact → Supports high-voltage motor circuits with a comfortable safety margin and robust isolation. Application → Common in heavy-duty drive applications and industrial power distribution. Feature → Power loss of 6.5 W per pole under AC-1 and 1.5 W per pole under AC-3 reduces energy waste and heat generation. Business Impact → Improves energy efficiency and reduces cooling requirements in control panels. Application → Beneficial for continuous operation in continuous-process lines. Feature → Mechanical and electrical endurance with up to 3,600 cycles per hour and 600 cycles per hour switching capacity. Business Impact → Higher uptime, lower maintenance costs, and extended service life in high-cycle environments. Application → Automotive, packaging, and material handling lines with frequent motor starts. Feature → Coil terminals IP20 and main terminals IP10 provide clear protection levels for wiring and connections. Business Impact → Safer installation and long-term reliability in cabinet environments. Application → Immediate compatibility with standard screw-terminal wiring and DIN rail assemblies.

Get a Quick Quote for a ABB 1SBL371074R8411

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL371074R8411? Enquire Now

FAQs

Installation with AX50‑AX80 accessories is straightforward due to the block design and compatible add-on auxiliary contact blocks. Use screw terminals, tighten coil terminals to 1 N·m and main terminals to 4 N·m, mount per the 82 mm width, and ensure the device sits within its IP20/IP10 protection envelope. This minimizes wiring errors and speeds up panel commissioning.
AC‑1 ratings cover non‑switching motor loads such as resistive or lightly inductive circuits, while AC‑3 ratings apply to motor switching with starting currents and overloads. For this contactor, AC‑1 currents reach up to 115 A at 690 V, and AC‑3 currents reach up to 65 A at 415–690 V, with corresponding power ratings. These figures guide proper sizing for reliable motor control.
Yes, the ABB 1SBL371074R8411 is rated for 690 V insulation and main circuit operation. It provides IP20 protection for control terminals and IP10 for main terminals, along with a 6 kV impulse withstand on the auxiliary circuit. This combination supports safe use in typical industrial control cabinets and power distribution.
The product carries CE, UL/CSA, CCC, and CQC certifications, plus relevant DoCs. CE and UL/CSA facilitate compliance in Europe and North America, while CCC/CQC address Chinese market requirements. This broad certification footprint helps streamline procurement for multi-region projects and reduces the need for multiple variants.
With a maximum mechanical switching frequency of 3600 cycles per hour and a maximum electrical frequency of up to 600 cycles per hour (AC‑1/AC‑3), the device supports high-cycle operation. Coupled with low coil power loss (6.5 W AC‑1, 1.5 W AC‑3 per pole) and robust build, this yields lower energy costs, longer service intervals, and a favorable return on investment in demanding automation lines.