ABB AF65B-30-00-12 Block Contactor - AF tech

Part Number: 1SBL387061R1200
Manufacturer
ABB
Part number
1SBL387061R1200

Quick Summary

AF65B-30-00-12 block contactor is a 3-pole device designed for motor control in industrial applications up to 30 kW. Engineers often struggle with voltage swings in control networks that trigger nuisance trips and energy waste. The AF65B family is built to IEC 60947-4-1 and UL 60335-2-40 standards, with CSA and CE/UKCA markings that support global compliance, including in rolling stock and factory environments. That combination of robust standards is complemented by a wide control voltage range and built-in surge protection, reducing panel energy use. Designed for easy installation and future expansion, it supports add-on auxiliary blocks and DIN-rail mounting to simplify scalable automation projects.

Product Information

Extended Description

1SBL387061R1200 ABB: The AF65B-30-00-12 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 30 kW / 400 V AC (AC-3) or 50 hp / 480 V UL and switching power circuits up to 105 A (AC-1) or 90 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
Motor control and protection for Rolling stock application_PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
55 mm
Product Net Depth / Length
111 mm
Product Net Height
125.5 mm
Product Net Weight
0.97 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 105 A | (690 V) 60 °C 90 A | (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 65 A | (440 V) 60 °C 65 A | (500 V) 60 °C 55 A | (690 V) 60 °C 39 A | (380 / 400 V) 60 °C 65 A | (220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 65 A | (440 V) 60 °C 65 A | (500 V) 60 °C 55 A | (690 V) 60 °C 39 A | (380 / 400 V) 60 °C 65 A | (220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 105 A | (110 V) 2 Poles in Series, 60 °C 90 A | (110 V) 2 Poles in Series, 70 °C 80 A | (110 V) 3 Poles in Series, 40 °C 105 A | (110 V) 3 Poles in Series, 60 °C 90 A | (110 V) 3 Poles in Series, 70 °C 80 A | (220 V) 3 Poles in Series, 40 °C 105 A | (220 V) 3 Poles in Series, 60 °C 90 A | (220 V) 3 Poles in Series, 70 °C 80 A | (72 V) 1-Pole, 40 °C 105 A | (72 V) 1-Pole, 60 °C 90 A | (72 V) 1-Pole, 70 °C 80 A | (72 V) 2 Poles in Series, 40 °C 105 A | (72 V) 2 Poles in Series, 60 °C 90 A | (72 V) 2 Poles in Series, 70 °C 80 A | (72 V) 3 Poles in Series, 40 °C 105 A | (72 V) 3 Poles in Series, 60 °C 90 A | (72 V) 3 Poles in Series, 70 °C 80 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 105 A | (110 V) 2 Poles in Series, 60 °C 90 A | (110 V) 2 Poles in Series, 70 °C 80 A | (110 V) 3 Poles in Series, 40 °C 105 A | (110 V) 3 Poles in Series, 60 °C 90 A | (110 V) 3 Poles in Series, 70 °C 80 A | (220 V) 3 Poles in Series, 40 °C 105 A | (220 V) 3 Poles in Series, 60 °C 90 A | (220 V) 3 Poles in Series, 70 °C 80 A | (72 V) 1-Pole, 40 °C 105 A | (72 V) 1-Pole, 60 °C 90 A | (72 V) 1-Pole, 70 °C 80 A | (72 V) 2 Poles in Series, 40 °C 105 A | (72 V) 2 Poles in Series, 60 °C 90 A | (72 V) 2 Poles in Series, 70 °C 80 A | (72 V) 3 Poles in Series, 40 °C 105 A | (72 V) 3 Poles in Series, 60 °C 90 A | (72 V) 3 Poles in Series, 70 °C 80 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 105 A | (110 V) 2 Poles in Series, 60 °C 90 A | (110 V) 2 Poles in Series, 70 °C 80 A | (110 V) 3 Poles in Series, 40 °C 105 A | (110 V) 3 Poles in Series, 60 °C 90 A | (110 V) 3 Poles in Series, 70 °C 80 A | (220 V) 3 Poles in Series, 40 °C 105 A | (220 V) 3 Poles in Series, 60 °C 90 A | (220 V) 3 Poles in Series, 70 °C 80 A | (72 V) 1-Pole, 40 °C 105 A | (72 V) 1-Pole, 60 °C 90 A | (72 V) 1-Pole, 70 °C 80 A | (72 V) 2 Poles in Series, 40 °C 105 A | (72 V) 2 Poles in Series, 60 °C 90 A | (72 V) 2 Poles in Series, 70 °C 80 A | (72 V) 3 Poles in Series, 40 °C 105 A | (72 V) 3 Poles in Series, 60 °C 90 A | (72 V) 3 Poles in Series, 70 °C 80 A
Rated Operational Power AC-3 (Pe)
(400 V) 30 kW | (415 V) 37 kW | (440 V) 37 kW | (500 V) 37 kW | (690 V) 37 kW | (380 / 400 V) 30 kW | (220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe)
(415 V) 37 kW | (440 V) 37 kW | (500 V) 37 kW | (690 V) 37 kW | (380 / 400 V) 30 kW | (220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value DC 2 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time
Between Coil De-energization and NC Contact Closing 19 ... 105 ms | Between Coil De-energization and NO Contact Opening 17 ... 100 ms | Between Coil Energization and NC Contact Opening 38 ... 95 ms | Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 4 ... 35 mm² | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² | Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 0 mm | Control Circuit 10 mm | Main Circuit 16 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Continuous Current Rating NEMA
0 A
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 90 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 5 hp | (200 ... 208 V AC) Three Phase 20 hp | (220 ... 240 V AC) Three Phase 25 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 50 hp | (550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 56 A | (200 ... 208 V AC) Three Phase 62.1 A | (220 ... 240 V AC) Three Phase 68 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 65 A | (550 ... 600 V AC) Three Phase 62 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Shock and Vibration Withstand acc. to IEC 61373
Category 1, Class B
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)40(B), AF(S)52(B), AF(S)65(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(S)40(B), (S)AF52(B), AF(S)65(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, Contactor, AF*40-30-**-**, AF40-40-**-**, AF40-22-**-**, AF*52-30-**-**, AF52-40-**-**,AF*65-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09 ... AF38(Z)B..(K), AF40B ... AF96B 3 and 4-pole contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09 ... AF38(Z)B..(K), AF40B ... AF96B 3 and 4-pole contactors
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
97 mm
Package Level 1 Gross Weight
1.07 kg
Package Level 1 EAN
3471523025158
Package Level 2 Units
box 10 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
10.7 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: 3-pole design for reliable motor control at high currents. Business Impact: Supports motors up to 30 kW with AC-3 duty, reducing starter failures and downtime. Application: Suitable for 400 V AC drives in manufacturing lines and machine tools. Feature: Wide control voltage range 48–130 V AC/DC. Business Impact: Maintains operation across fluctuating control networks, minimizing mis-trips and energy waste. Application: Ideal for plants with variable supply or remote control panels. Feature: Built-in surge protection and compact AF block design. Business Impact: Fewer external suppressors and smaller cabinet footprint, cutting panel costs. Application: Rail and factory environments with electrical transients. Feature: Screw terminals and DIN-rail mounting (TH35-15/TH35-7.5). Business Impact: Fast, vibration-resistant installation with scalable cabinet layouts. Application: New install projects and retrofits in control panels. Feature: High integration with add-on auxiliary contact blocks. Business Impact: Easily extend control logic for signaling and interlocks, reducing integration time. Application: Complex automation sequences and safety interlocks. Feature: Compliance and ratings (IEC/EN 60947-1, IEC/EN 60947-4-1, UL, CSA, CE/UKCA). Business Impact: Global deployment with validated safety and performance. Application: Multinational manufacturing and rolling stock projects.

Get a Quick Quote for a ABB 1SBL387061R1200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL387061R1200? Enquire Now

FAQs

AF65B-30-00-12 uses DIN rail mounting with TH35-15 or TH35-7.5 profiles and is designed for screw-terminal connections. Main circuit terminals accept flexible Ferrule 1/2x 4–35 mm² or rigid 1/2x 6–35 mm², while control circuit terminals use flexible Ferrule 0.75–2.5 mm² or rigid 1/2x 1–2.5 mm². Tightening torques are 4 N·m (main) and 1.2 N·m (control).
At 690 V, AC-1 Ie is 105 A (40 °C), 90 A (60 °C), and 80 A (70 °C). For AC-3, Ie is 39–65 A depending on voltage and temperature (e.g., 65 A at 415–440 V, 60 °C; 55 A at 500 V; 39 A at 690 V). AC-3e and DC ratings follow similar voltage-based deratings.
Yes. The AF65B-30-00-12 is designed for 3-pole motor control with IEC/UL/CSA approvals and data supporting rolling stock applications. Its 690 V main circuit rating, 48–130 V control range, and high short-time withstand current (Icw) support reliable operation in demanding conveyor and rail-related drives.
The device complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40, CSA C22.2, and CE/UKCA marking. It is RoHS and REACH compliant, with a UL/CSA listing for safety and performance in global deployments.
The 48–130 V coil range reduces the need for multiple voltage conversions, cutting wiring and power supply costs. Built-in surge protection lowers transient-related failures, reducing maintenance and unplanned downtime. The compact block design and compatibility with auxiliary blocks also shorten installation and future expansion timelines, improving total cost of ownership.