ABB 1SBL391201R4200 Block Contactor - 4P 1000V IEC/UL
Part Number: 1SBL391201R4200
Quick Summary
ABB 1SBL391201R4200 is a four-pole block contactor for switching power circuits up to 125 A. In industrial automation, compact, reliable switching and easy wiring matter, and this device delivers both. Engineered for dependable operation in demanding environments, it offers screw terminals and a scalable platform that accepts add-on auxiliary blocks and accessories, simplifying future upgrades. The unit carries CE, UKCA, and UL certifications, with additional BV, DNV, and RINA approvals supporting global deployment and regulatory compliance. For OEMs and panel builders, the combination of DIN-rail mounting, standard dimensions, and broad coil voltage compatibility translates into shorter assembly times, lower spares inventory, and reduced maintenance overhead, while maintaining safe, robust control of power circuits.
Product Information
Extended Description
1SBL391201R4200 ABB: The AFC80-40-00-42 is a 4-pole (4 N.O) - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 125 A (IEC AC-1) or 105 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 277 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.45 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 277 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 10 ... 19 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 6 ... 15 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
97.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
3471523023529
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Coil voltage compatibility and control: The contactor operates with control voltages of 230-240 V AC at 50/60 Hz or 277 V AC at 60 Hz, with coil consumption values designed for efficient energy use. This broad range reduces stocking multiple coil variants and simplifies control wiring in global installations. Application: suitable for AC control tasks in conveyors, pumps, and fans. Business impact: lowers inventory costs and improves commissioning speed. Electrical ratings and performance: Main circuit rated 125 A for IEC AC-1 at 690 V with 40 °C ambient, and 105 A at 60 °C, plus 80 A for AC-3 across several voltages. Maximum electrical switching frequency and short-time withstand ratings ensure reliable motor control during startup and overload conditions. Application: motor starting and high-load switching in manufacturing lines. Business impact: higher uptime and predictable thermal behavior. Mechanical and installation convenience: 4P design with screw terminals and mounting options on TH35-15 or TH35-7.5 DIN rails, plus versatile conductor connections for both main and control circuits. Control circuit connections accommodate 0.75–2.5 mm² and main circuit connections 6–70 mm². Application: quick panel integration and flexible wiring layouts. Business impact: streamlined installation, reduced labor time, and easier future upgrades. Standards, protection, and environment: Compliance with IEC/EN 60947-1, 60947-4-1, UL 60947-1, UL 60947-4-1, and CSA equivalents; IP20 on coil terminals and IP10 on main terminals; RoHS/REACH; capable in temperatures up to 70 °C and up to 3000 m altitude without derating. Application: safe operation in diverse industrial environments. Business impact: regulatory confidence and long-term reliability. Extendibility and lifecycle cost: Block-type design supports add-on auxiliary contact blocks and accessories, enabling scalable control schemes and reduced total cost of ownership. Application: customization for complex control logic and future system expansion. Business impact: future-proofing and improved ROI.
Get a Quick Quote for a ABB 1SBL391201R4200
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL391201R4200?
Enquire Now
FAQs
The contactor supports 230–240 V AC at 50/60 Hz and 277 V AC at 60 Hz. Coil consumption values include holding and pull-in requirements, enabling efficient energy use and broad regional deployment.
Yes. It is rated for IEC AC-1 up to 125 A at 690 V (40 °C) and 105 A at 60 °C, and AC-3 up to 80 A across applicable voltages. This makes it suitable for motor starting and other power switching tasks.
It supports DIN rail mounting on TH35-15 or TH35-7.5 profiles, and can be screwed to panels with two screws (M4 or M6). Main and control terminations accommodate a range of conductor sizes.
It holds CE and UKCA declarations of conformity, UL certificates, and additional approvals such as BV, DNV, and RINA, ensuring cross-market regulatory compliance and safety.
Low coil energy consumption, modular accessory compatibility, and a compact form factor reduce energy use, spare parts, and maintenance time, while enabling easy future upgrades and scalable control logic.