ABB Block Contactor 1SBL391201R5100 - 1000 V IEC/UL
Part Number: 1SBL391201R5100
Quick Summary
Block Contactor ABB is a high-capacity switch that controls motors in industrial automation systems. Designers often contend with coil voltage compatibility, installation complexity, and long-term maintenance costs. This device complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, and CE/UKCA declarations, supporting global deployments. Its DIN-rail mounting and screw-terminal design offer fast, reliable panel integration while reducing installation time and spare-part inventory. In addition, the four-pole configuration and scalable accessory options deliver a robust solution for demanding drive applications, helping your organization improve uptime and energy efficiency across manufacturing lines.
Product Information
Extended Description
1SBL391201R5100 ABB: The AFC80-40-00-51 is a 4-pole (4 N.O) - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 125 A (IEC AC-1) or 105 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.45 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 10 ... 19 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 6 ... 15 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
97.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
3471523024595
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Four NO main contacts in a 4P block design. Benefit: Enables compact, reliable three-phase motor control with a single device, reducing panel footprint and wiring complexity in automation panels. Application: Motor starters in conveyors and pumping stations. Feature: Main circuit rated up to 1000 V and up to 125 A (IEC AC-1). Benefit: Supports high-voltage, high-current switching with a safe insulation margin, improving system reliability and protection against switching transients. Application: Heavy-load drives in material handling and process automation. Feature: Coil control voltage compatible with 400-415 V AC (50 Hz) or 480 V AC (60 Hz). Benefit: Cross-regional compatibility for global plants, simplifying global procurement and stock planning. Application: Control circuits across multinational facilities. Feature: DIN rail mounting (TH35-15 or TH35-7.5) and Screw terminals. Benefit: Fast, vibration-tolerant installation with robust, field-proven connections; easy retrofits and panel upgrades. Application: Control panels in machine houses and MCCs. Feature: Extendable with auxiliary contact blocks and accessories. Benefit: Scales functionality without replacing the base unit, reducing downtime during upgrades. Application: Customizable control circuits for interlocking and status indication. Feature: Mechanical and Electrical switching performance (600 cycles/hour AC-1, 3600 cycles/hour mechanical). Benefit: Predictable lifecycle and lower maintenance costs in automation sequences with frequent switching. Application: Indexing drives and batch processing lines. Feature: Terminology and protection (Screw Terminals, IP20 coil, IP10 main). Benefit: Clear mounting and protection boundaries that simplify wiring and improve safety in control cabinets. Application: Industrial panels with rigorous cleanliness and safety requirements.
Get a Quick Quote for a ABB 1SBL391201R5100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL391201R5100?
Enquire Now
FAQs
This ABB four-pole contactor is designed for DIN rail mounting using TH35-15 or TH35-7.5 rails. It accepts standard screw-terminal connections for the main circuit, enabling quick panel integration and reliable mechanical securement in compact control panels.
For this unit, main circuit rated voltage is up to 1000 V with AC-1 current up to 125 A at 690 V (40 °C). AC-3 ratings vary by voltage, with 80 A at 415–440 V, and 65 A at 500 V, down to 49 A at 690 V. This supports motor starting and star-delta type loads in typical industrial drives.
Yes. It supports a 1000 V rated main circuit and 400–415 V (50 Hz) / 480 V (60 Hz) coil control, enabling operation across regional electrical systems without a dedicated voltage transformer, reducing component diversity in mixed installations.
The AFC family complies with IEC 60947-1 and 60947-4-1, UL 60947-1 and 60947-4-1, CSA equivalents, and CE/UKCA declarations. This ensures regulatory compliance for global deployments and simplifies cross-border panel certifications.
Expect reduced panel space due to four-pole high-current design, lower maintenance from reliable 125 A AC-1 ratings, and optional accessories for easy expansion. The coil voltage compatibility minimizes stocking complexity, contributing to faster commissioning and lower downtime across multiple lines.