ABB 1SBL391201R8500 Block Contactor - 1000 V IEC/UL
Part Number: 1SBL391201R8500
Quick Summary
ABB 1SBL391201R8500 Block Contactor is a rugged AC switching device designed to control power circuits in demanding industrial automation. Many buyers struggle with coil voltage compatibility and easy DIN-rail mounting in tight control panels. It meets IEC/EN 60947-1 and IEC/EN 60947-4-1, UL 60947-1/60947-4-1, with CE and UKCA conformity ensuring global compliance. Designed for 380-400 V (50 Hz) / 400-415 V (60 Hz) control voltages and a 4-pole configuration, it helps engineers streamline installation and optimize panel space while delivering reliable AC-1 and AC-3 performance.
Product Information
Extended Description
1SBL391201R8500 ABB: The AFC80-40-00-85 is a 4-pole (4 N.O) - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 125 A (IEC AC-1) or 105 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 380 ... 400 V AC 50 Hz / 400 ... 415 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.45 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 0 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 380 ... 400 V | 60 Hz 400 ... 415 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 10 ... 19 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 6 ... 15 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 7-1/2 A | (200 ... 208 V AC) Three Phase 25 A | (220 ... 240 V AC) Three Phase 30 A | (240 V AC) Single Phase 15 A | (440 ... 480 V AC) Three Phase 60 A | (550 ... 600 V AC) Three Phase 75 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
97.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
3471523019508
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 4-pole 4 NO main contacts and block contactor design. Business impact: reduces wiring complexity and panel footprint, enabling compact, reliable power switching in control panels. Application: suitable for high-current AC-1 and AC-3 loads in conveyors and machine tools. Feature: Rated main circuit voltage up to 1000 V and wide operating range. Business impact: supports multi-voltage installations and future-proof upgrades without swapping hardware. Application: ideal for high-voltage power distribution and heavy-duty motor control in industrial automation.Feature: coil voltage options 380-400 V at 50 Hz and 400-415 V at 60 Hz with defined coil consumption. Business impact: improves control reliability while balancing energy use and hold/pull-in behavior. Application: optimized for European and North American grid standards in mixed-voltage facilities.Feature: DIN rail mounting (TH35-15) and screw terminal connections. Business impact: fast, secure installation with less panel space and reduced vibration-related loosening. Application: factory automation panels, control cabinets, and retrofit projects.Feature: Extendability with add-on auxiliary contact blocks and accessories. Business impact: scalable I/O expansion avoids replacement when expansion is required. Application: scalable control solutions for growing systems and modular architectures.Feature: Robust safety and compliance features including 1000 V insulation, 8 kV impulse withstand, and CE/UKCA/UL/CSA certifications. Business impact: mitigates risk, simplifies validation, and supports global product rollout. Application: critical in industries with strict safety and regulatory requirements.
Get a Quick Quote for a ABB 1SBL391201R8500
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL391201R8500?
Enquire Now
FAQs
The device is designed for TH35-15 DIN rails. Mount the block contactor securely on the rail, align the terminals, and tighten to the recommended torque. Use 2 x M4 or 2 x M6 screws if mounting by screws is preferred. Verify wire sizes for main circuit 6-70 mm² and control circuit 0.75-2.5 mm², and ensure coil voltage matches the 380-400 V or 400-415 V specification depending on your region.
For AC-1 (main circuit) at 690 V and 40 °C, Ie is 125 A; for AC-3 (motor switching) at 60 °C and 415 V, Ie is 80 A. The device supports up to 1000 V insulation and offers a maximum mechanical switching frequency of 3600 cycles per hour, with a short-time withstand current up to 300 A for 1 minute and 1200 A for 1 second.
Yes. With 4 NO mains contacts, 4P configuration, and AC-3 capable ratings at multiple voltages, it is well-suited for motor control in packaging lines. Its 1000 V insulation, robust control voltage options, and DIN rail mounting simplify integration in compact panels while maintaining efficient switching performance under typical packaging-line loads.
The product complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, UL 60947-1 and UL 60947-4-1, and CSA equivalents, with CE and UKCA declarations. It also meets environmental and RoHS/REACH requirements, supporting global deployments in regulated industries.
The 1SBL391201R8500 offers reliable, energy-conscious coil performance, scalable accessory options, and a compact footprint that reduces panel space and installation time. Its long-term durability, broad certification coverage, and compatibility with common control systems can lower maintenance costs and minimize downtime, delivering a favorable total cost of ownership in automation projects.