ABB 1SBL391501R5100 Block Contactor - IEC/UL 1000 V
Part Number: 1SBL391501R5100
Quick Summary
ABB AFC block contactor is designed for AC power switching in motor control and general load circuits. The 4-pole design minimizes coil energy and footprint while delivering reliable switching at 125 A AC-1 and 80 A AC-3 across a wide voltage range. It carries CE, UKCA, UL/CSA, and CB certifications to support global deployments in industrial plants. With screw terminals, DIN-rail mounting, and optional auxiliary blocks, it simplifies installation, maintenance, and spare parts management while enhancing plant uptime and energy efficiency. Designed for environments up to 3000 m altitude and featuring IP20 protection for coils, this device integrates easily into modern automation architectures and supports scalable control solutions for future-proof plants.
Product Information
Extended Description
1SBL391501R5100 ABB: The AFC80-22-00-51 is a 4-pole (2 N.O + 2 N.C) - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 125 A (IEC AC-1) or 105 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.45 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 480 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 10 ... 19 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 6 ... 15 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
97.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
3471523024618
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 4-pole, 2 NO + 2 NC main contacts. Business impact: enables safe, simultaneous switching of line and motor circuits, reducing wiring errors and misconfiguration. Application: motor starters and power distribution in conveyors and pumps. Feature: 1000 V insulation voltage and wide operating voltage (control 400–415 V AC 50/60 Hz; 480 V). Business impact: supports dual-voltage control schemes and broad regional deployment. Application: mixed-voltage automation panels with a single family of contactors. Feature: main current ratings up to 125 A AC-1 and 80 A AC-3 with precise voltage ratings. Business impact: minimizes part diversity and aligns with IEC/UL standards, lowering inventory costs. Application: general use and IEC/UL-coordinated load circuits in machinery. Feature: modular add-on auxiliary contact blocks and screw terminals. Business impact: simplifies field upgrades, reduces maintenance time, and extends functionality without full replacement. Application: retrofit projects and future-proof control panels with scalable I/O. Feature: robust mechanical and electrical endurance (Icw, It, operating times). Business impact: improves uptime, reduces unexpected outages, and supports high-cycle environments. Application: automated line starts, packaging, and material handling lines. Feature: comprehensive certifications (CE, UKCA, UL/CSA, CB, BV, DNV, RINA). Business impact: accelerates global approvals, enables export readiness, and minimizes compliance risk. Application: engineering projects requiring international market access.
Get a Quick Quote for a ABB 1SBL391501R5100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL391501R5100?
Enquire Now
FAQs
Install on TH35-15 or TH35-7.5 DIN rails, ensuring clearance for cooling and wiring. Use two M4 or two M6 screws if mounting by screws, and connect the main circuit with appropriate cross-section conductors (rigid 6–70 mm² or flexible 6–50 mm² as specified). Torque control circuit terminals to 1.2 N·m and main circuit terminals to 6 N·m. Follow the included installation instructions for safe, compliant mounting.
AC-1 rated operational current is up to 125 A at 690 V (40 °C), 105 A at 690 V (60 °C), and 90 A at 690 V (70 °C). AC-3 rated current varies by voltage; for common configurations it includes 80 A at 415–440 V (60 °C) and 65–49 A at higher voltages. These ratings support typical motor starting and load switching with known short-time withstand and breaking capacity values.
Yes. The 4P design with 2 normally open and 2 normally closed contacts provides reliable motor control for conveyors and pumps. Its 1000 V insulation, wide coil voltage range, fast operate times (6–22 ms), and modular accessories enable robust, scalable control of motor loads while meeting IEC/UL standards and providing predictable switching performance in demanding environments.
The device carries CE and UKCA declarations, UL/CSA approvals, CB certification, and additional BV, DNV, and RINA attestations, plus RoHS and REACH compliance. This broad certification portfolio supports global market access, reduces regulatory risk for cross-border projects, and aligns with typical supplier qualification requirements in multinationals.
Maintenance benefits arise from modular add-on contact blocks, screw-terminal design for dependable connections, and a compact form factor that reduces panel space. High reliability, low energy consumption per pole (8 W AC-1, 3.2 W AC-3) and predictable life cycles translate to lower maintenance intervals and reduced downtime, delivering a favorable total cost of ownership in automation lines.