ABB 1SBL391501R8800 Contactor - IEC/EN 60947-4-1

Part Number: 1SBL391501R8800
Manufacturer
ABB
Part number
1SBL391501R8800

Quick Summary

ABB 1SBL391501R8800 Contactor is a 4-pole device that switches power circuits in industrial automation. Customers often struggle with coil voltage tolerance, downtime, and limited expansion options when selecting contactors. This model carries CE and UKCA markings along with UL/CSA approvals, and offers IP20 protection on auxiliary terminals with IP10 on main terminals to support reliable operation in tough environments. Its design supports easy expansion with add-on auxiliary contact blocks and accessories, plus DIN rail mounting for streamlined panel integration. For businesses, this means consistent performance, reduced maintenance, and scalable control solutions across global manufacturing environments.

Product Information

Extended Description

1SBL391501R8800 ABB: The AFC80-22-00-88 is a 4-pole (2 N.O + 2 N.C) - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 125 A (IEC AC-1) or 105 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 240 ... 260 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
90 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.45 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 0 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 10 ... 19 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 6 ... 15 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 7-1/2 A | (200 ... 208 V AC) Three Phase 25 A | (220 ... 240 V AC) Three Phase 30 A | (240 V AC) Single Phase 15 A | (440 ... 480 V AC) Three Phase 60 A | (550 ... 600 V AC) Three Phase 75 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09 ... AFC80 4-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AFC40 ... AFC80 4-pole contactors | UL-CA Certificate of Compliance AFC40 ... AFC80 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
97.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.77 kg
Package Level 1 EAN
3471523019539
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Four-pole block contactor with 2 normally open and 2 normally closed contacts. Business Impact: Enables reliable control of multi-line power circuits up to 125 A IEC AC-1, reducing downtime and wiring complexity. Application: Motor starters and line switching in conveyors and pumps. Feature: Coil voltage compatibility for 50 Hz and 60 Hz supply (230-240 V / 240-260 V). Business Impact: Global applicability across regional power systems, minimizing inventory with a single family. Application: Machines deployed internationally and in mixed-voltage plants. Feature: Extendable with add-on auxiliary contact blocks and a wide range of accessories. Business Impact: Scales control logic without replacing the main unit, lowering lifecycle cost. Application: Complex automation sequences requiring customized signaling. Feature: DIN rail mounting TH35-15 and optional screw mounting. Business Impact: Fast, secure installation in control panels with reduced labor time. Application: Panel builders and field service deployments. Feature: Screw terminals with clear wiring capacity (main up to 70 mm², control up to 2.5 mm²). Business Impact: Robust, vibration-tolerant connections that persist in demanding environments. Application: Heavy-duty industrial machinery and process equipment. Feature: Protection ratings (Auxiliary IP20, Main IP10). Business Impact: Safer wiring and improved ingress protection in critical control wiring. Application: Control circuits in open or semi-enclosed panels. Feature: Power and fault tolerance data (Ith 125 A, Icw 140–1200 A, Ui 1000 V). Business Impact: Strong withstand ratings for short-time faults and long service life. Application: High-demand switching in AC-1 and AC-3 motor control tasks. Feature: Efficiency metrics (8 W AC-1 per pole, 3.2 W AC-3 per pole). Business Impact: Lower running costs and cooler operation in continuous duty applications. Application: High-cycle industrial controls with extended duty cycles.

Get a Quick Quote for a ABB 1SBL391501R8800

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL391501R8800? Enquire Now

FAQs

Yes. The unit is designed for mounting on TH35-15 DIN rails (IEC 60715) and can also be mounted with 2 x M4 or 2 x M6 screws as an alternative.
AC-1 rated current is up to 125 A at 690 V (40 °C), 105 A at 690 V (60 °C), and 90 A at 690 V (70 °C). AC-3 rated current varies by voltage and temperature, up to 80 A at 415–440 V (60 °C) and 25 A at 1000 V (60 °C).
The coil is 230–240 V AC for 50 Hz operation and 240–260 V AC for 60 Hz operation.
It carries CE and UKCA declarations, UL/CSA certifications, and CB, BV, DNV, and RINA certificates are referenced in the product documentation for broader compliance and traceability.
Ambient operating range is -40 to 70 °C, with an IP20 rating on auxiliary terminals and IP10 on main terminals. The device supports up to 3000 m altitude without derating and is suitable for Category B climatic conditions.