ABB 1SBL397001N1100 Block Contactor - UL/CSA LZGH2 A2L

Part Number: 1SBL397001N1100
Manufacturer
ABB
Part number
1SBL397001N1100

Quick Summary

ABB 1SBL397001N1100 Block Contactor is designed to safely switch three-phase motors in industrial power circuits, delivering reliable operation under load. Engineers often face space constraints, wiring complexity, and the need for robust protection against short circuits, which this device helps mitigate with a compact, high-performance design. It carries CE and UL/CSA certifications, and features IP20 protection on coil terminals with IP10 protection on main terminals to support safe operation in rugged environments. With DIN-rail mounting and screw-terminal options, this contoractor simplifies installation while enabling scalable motor control in automated panels and machinery.

Product Information

Extended Description

1SBL397001N1100 ABB: AF80N3 NEMA contactors are mainly used for controlling 3-phase motors and power circuits up to 600 VAC. These contactors are of the block type design with 3 main poles.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.22 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE Category
Product Not in WEEE Scope
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09N ... AF80N NEMA contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09N ... AF80N NEMA contactors
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.34 kg
Package Level 2 Units
8 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature three-pole main contacts (NO) for reliable three-phase motor control → Business impact supports robust power switching with up to 1000 V insulation rating and up to 80 A AC-3 at high voltages, reducing downtime and expanding applicable motor sizes. Application suitable for 3P motors in packaging, extrusion, and process lines. Feature coil control voltage range 24–60 V (AC and DC operation) → Business impact enables flexible integration with low-voltage control circuits and low wiring complexity, lowering control panel costs and increasing control reliability. Application in control circuits for industrial automation with 50/60 Hz compatibility. Feature energy efficiency with power loss of 3 W per pole (AC-3) and 7.6 W per pole (AC-1) → Business impact lowers energy consumption and thermal load in enclosures, supporting safer long-term operation. Application in continuous duty and infrequent start-stop cycles. Feature DIN rail mounting TH35-15 and optional screw mounting with 2 x M4/M6 screws → Business impact speeds up installation and simplifies retrofits in existing panels. Application across standard DIN rail assemblies in factory automation. Feature flexible with Ferrule and Insulated Ferrule terminations for main and auxiliary circuits (up to 50 mm² main, 2.5 mm² auxiliary) → Business impact ensures solid, maintenance-friendly connections with wide cable compatibility. Application in highly variable industrial wiring environments. Feature IP20 coil terminals and IP10 main terminals → Business impact provides protection against contact with live parts, improving safety and compliance in control cabinets. Application in indoor industrial environments with moderate dust and pollutants. Feature wide standards support (IEC/EN 60947-1, IEC/EN 60947-4-1, UL/CSA) → Business impact ensures regulatory compliance across global facilities, reducing procurement risk. Application in multinational manufacturing setups requiring uniform component specs. Feature 3P, 3 NO main contacts and 3 poles with compact dimensions (70 mm width, 116 mm depth, 125.5 mm height) → Business impact enables compact footprints in tight control panels, freeing space for additional devices. Application in compact machine builds and space-constrained panels.

Get a Quick Quote for a ABB 1SBL397001N1100

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL397001N1100? Enquire Now

FAQs

This 3-pole block contactor supports DIN rail mounting on TH35-15 rails and can also be installed using two diagonal screws (M4 or M6). This combination offers fast installation, easy retrofits, and reliable retention in vibration-prone environments.
Rated AC-3 current varies with voltage: up to 80 A at 415–690 V and up to 25–49 A at higher voltage classes, with P_e values around 37–45 kW depending on voltage. These ratings enable safe, code-compliant motor starting and reliable switching of standard industrial loads.
Yes. The product carries CE and UL/CSA certifications, and features IP20 duty for coil terminals and IP10 for main terminals, supporting safe operation in typical factory environments while meeting global conformity requirements.
Main circuit terminals accept flexible ferrules up to 50 mm² and rigid conductors up to 70 mm², with a tightening torque of 6 N·m for main circuits and 1.2 N·m for control circuits to ensure secure, vibration-resistant connections.
The minimum order quantity is 1 piece, packaged as 1 piece per box with a package level 1 footprint of approximately 150 x 150 x 103 mm and a gross weight of about 1.34 kg, making it straightforward to scale in multi-line installations.