ABB 1SBL397001N1200 Contactor - AF80N3 3P UL/CSA IEC 60947-4-1

Part Number: 1SBL397001N1200
Manufacturer
ABB
Part number
1SBL397001N1200

Quick Summary

ABB 1SBL397001N1200 Contactor is a three-pole motor switch for controlling heavy 3‑phase drives. Engineers often face coil voltage mismatches, thermal buildup, and mounting constraints when integrating contactors in compact panels. This ABB AF80N3 solution delivers reliable switching for motors up to 600 VAC with a wide control voltage range and robust mechanical design. It carries critical certifications such as IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60335-2-40, along with CSA recognition, providing regulatory assurance across global markets. The combination of DIN-rail compatibility, low heat dissipation, and flexible wiring supports scalable automation projects, while ensuring safety and operational efficiency in demanding environments.

Product Information

Extended Description

1SBL397001N1200 ABB: AF80N3 NEMA contactors are mainly used for controlling 3-phase motors and power circuits up to 600 VAC. These contactors are of the block type design with 3 main poles.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.22 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE Category
Product Not in WEEE Scope
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09N ... AF80N NEMA contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09N ... AF80N NEMA contactors
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.34 kg
Package Level 2 Units
8 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature → Business Impact → Application: Coil voltage range of 48–130 V is compatible with common control architectures, reducing spare part complexity and enabling seamless integration with existing control panels. This leads to lower commissioning time and improved system reliability in HVAC, pump, and conveyor drives. Feature → Low power loss per pole (7.6 W AC-1; 3 W AC-3) reduces heat buildup and cooling requirements, enhancing energy efficiency and extending component life in continuous operation applications. Feature → 3N/O main contacts (3P) with no NC or auxiliary contacts simplifies wiring and minimizes contact resistance, delivering predictable performance for standard motor starting in manufacturing lines. Feature → Wide insulation voltage (1000 V) and 8 kV impulse withstand support compliance and protection in harsh electrical environments, reducing risk of insulation failure and downtime. Feature → TH35-15 DIN-rail mounting and optional screw mounting provide flexible installation options, speeding up panel assembly and maintenance. Feature → Flexible conductor connections for main and control circuits (6–50 mm² main, 0.75–2.5 mm² auxiliary) support diverse cabling strategies and minimize termination effort. Feature → IP20 coil terminals and IP10 main terminals, combined with robust torque specs (1.2 N·m control, 6 N·m main), ensure secure and durable electrical connections in industrial settings. Feature → UL/CSA and CE documentation plus DoC support global compliance, reducing procurement risk and enabling standardized procurement across multi-site operations. Application context: Suitable for 3‑phase motor control in manufacturing lines, packaging systems, water treatment, and material handling where reliable switching and regulatory compliance are essential.

Get a Quick Quote for a ABB 1SBL397001N1200

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL397001N1200? Enquire Now

FAQs

Mounting is supported on TH35-15 DIN rails as a standard option, with screw mounting as an alternative. Ensure proper alignment on a 35x15 mm rail and use the 2 x M4 or 2 x M6 screws placed diagonally if screws are chosen. This provides secure mechanical support while maintaining easy removal for maintenance.
The coil is rated for 48–130 V across AC, DC, and 50/60 Hz control circuits. This wide window supports diverse control schemes from standard 120 V to DC drive systems, reducing the need for multiple coil variants on the same panel.
AC-3 rated current is up to 80 A at 415–690 V depending on temperature, and AC-3e follows similar voltage ranges with current up to 80 A at 415–440 V, decreasing at higher voltages. This makes the contactor suitable for typical motor starting and running loads in industrial drives.
Yes. The product carries UL and CSA listings, CE declarations, and DoCs for relevant standards, including IEC 60947-1/4-1 and UL 60335-2-40. This provides regulatory assurance for global deployment and multi-site procurement.
Main circuit connections support flexible ferrule or rigid conductors from 6 to 50 mm², with a tightening torque of 6 N·m. Control circuits accept ferrule 0.75–2.5 mm² and rigid 0.75–2.5 mm², tightened to 1.2 N·m for coil terminals. Ensure proper stripping length and confirm IP ratings (coil IP20, main IP10) during assembly.