ABB 1SBL397001N1400 Block Contactor - UL/CSA IEC 60947-4-1

Part Number: 1SBL397001N1400
Manufacturer
ABB
Part number
1SBL397001N1400

Quick Summary

ABB 1SBL397001N1400 Block Contactor is designed to switch and control 3-phase motors in industrial power circuits. This solution addresses downtime and inconsistent performance that engineers often experience with legacy starters. It complies with IEC/EN 60947-1, IEC 60947-4-1, UL 60335-2-40 and CSA standards, providing broad regulatory coverage for global deployments. The compact 3-pole block design supports easy installation on standard DIN rails, while the 250–500 V control voltage range offers flexible integration with mixed-voltage plants. For procurement teams, this combination translates into reduced engineering effort, lower stock complexity, and dependable lifecycle performance across demanding manufacturing environments.

Product Information

Extended Description

1SBL397001N1400 ABB: AF80N3 NEMA contactors are mainly used for controlling 3-phase motors and power circuits up to 600 VAC. These contactors are of the block type design with 3 main poles.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.17 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 60 °C 100 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7.6 W | at Rated Operating Conditions AC-3 per Pole 3 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE Category
Product Not in WEEE Scope
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
Declaration of Conformity - CE
EU Declaration of Conformity AF09N ... AF80N NEMA contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09N ... AF80N NEMA contactors
UL Certificate
UL-US-L312527-1141-10303102-9 | UL-CA-L312527-4141-10303102-9
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.29 kg
Package Level 2 Units
8 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Three-pole block construction with three normally open main contacts provides dependable motor switching at voltages up to 1000 V. This improves startup reliability and reduces contact downtime in demanding applications. Ideal for 3-phase motors on conveyors, pumps, and fans in manufacturing lines. Control voltage range of 250–500 V across 50/60 Hz or DC supports flexible interfacing with existing control systems, reducing the need for different coil versions during upgrades or retrofits. This translates to shorter project timelines and lower wiring complexity on new machines or line expansions. Insulation voltage up to 1000 V and impulse withstand capability of 8 kV offer robust protection against transient events. This helps maintain system integrity in harsh industrial environments and simplifies compliance across multi-region deployments. DIN rail mounting via TH35-15 and a compact footprint (70 mm x 116 mm x 125.5 mm) with a weight of 1.17 kg delivers space savings in control panels and faster installation, especially in compact machine and panel designs. Power loss of 7.6 W per pole (AC-1) and 3 W per pole (AC-3) supports cooler operation and energy efficiency, potentially reducing cooling requirements and operating costs over the motor’s life. Flexible wiring options include screw terminals with various conductor sizes for main, auxiliary, and control circuits, enabling straightforward panel wiring and maintenance workflows. This reduces installation time and minimizes the risk of wiring errors in high-mix environments. Compliance and certifications—IEC/EN 60947-1, 60947-4-1, UL/CSA—provide global acceptance for panel builders and machine OEMs, streamlining procurement and reducing re-work during audits or customer approvals. Environmental and mounting considerations align with standard industrial practices, making this contactor a reliable building block in industrial automation and electrical protection schemes.

Get a Quick Quote for a ABB 1SBL397001N1400

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL397001N1400? Enquire Now

FAQs

The device uses TH35-15 DIN rail mounting for quick, secure installation in control panels. Main circuit wires should be 1/2 x 6 … 50 mm², while control circuit wires range from 0.75 … 2.5 mm² flexible with ferrule or 0.75 … 2.5 mm² insulated ferrule. Stripping lengths are 17 mm for main and 10 mm for control circuits. Use 2 x M4 or 2 x M6 screws diagonally if mounting by screws is required.
Main circuit rated up to 1000 V with AC-1 currents up to 100 A at 1000 V, 125 A at 690 V, and various AC-3 values up to 80 A at 415/440 V and 65 A at 500 V. Control circuit accepts 50 Hz or 60 Hz at 250–500 V, while power loss is 7.6 W per pole (AC-1) and 3 W per pole (AC-3).
Yes. It supports 380/400 V and 415/440 V mains within AC-3 and AC-1 ratings, with 3-pole operation. The device has 3 normally open main contacts and can drive motors in 3-phase networks common in packaging, material handling, and process automation, delivering reliable switching with robust overload and short-time withstand ratings.
It complies with IEC 60947-1 and IEC 60947-4-1 for general and motor controllers, UL 60335-2-40, UL 60947-1, and UL 60947-4-1, plus CSA equivalents. It also carries CE, UKCA declarations and has RoHS/REACH compliance, ensuring global acceptance and safety in household and industrial equipment, as well as HVAC and appliance applications.
Maintenance is minimized by robust contact design and high insulation ratings, reducing downtime due to failures. The unit’s compact footprint and screw-terminal wiring simplify inspection and replacement in existing panels. Its efficiency (low watt loss) lowers cooling energy, while UL/CSA/IEC compliance reduces risk during audits, contributing to lower lifecycle costs and predictable ROI.