ABB 1SBL397201R1300 Block Contactor - IEC 60947-4-1

Part Number: 1SBL397201R1300
Manufacturer
ABB
Part number
1SBL397201R1300

Quick Summary

ABB 1SBL397201R1300 Block Contactor enables reliable motor control in industrial applications. Fluctuating control voltages and unstable networks often cause nuisance trips and wasted energy in panel wiring. It complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40 listings, and CE declarations, ensuring global safety and compliance. With AF technology and built-in surge protection, it reduces panel complexity and energy use while delivering robust performance in demanding environments. Designed for easy integration with add-on auxiliary blocks and a wide range of accessories, it supports scalable automation and cost-effective maintenance for uptime and ROI.

Product Information

Extended Description

1SBL397201R1300 ABB: The AF80-40-00-13 is a 4 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.44 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value 50 Hz 4 V·A | Average Holding Value 60 Hz 4 V·A | Average Holding Value DC 2 W | Average Holding Value, from Warm State 2 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 7-1/2 A | (200 ... 208 V AC) Three Phase 25 A | (220 ... 240 V AC) Three Phase 30 A | (240 V AC) Single Phase 15 A | (440 ... 480 V AC) Three Phase 60 A | (550 ... 600 V AC) Three Phase 75 A
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations
3g Closed Position & 2g Open Position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
2b091a0d-decf-4ad7-a73f-b0293dc60388 France (FR)
Simplified SCIP
8417282e-6c21-4c2c-96cd-e3dcbad528cb France (FR) | f2babb07-8653-4166-816f-d1e501f87e41 Germany (DE) | 1d1bc94f-e6c2-4b68-8982-2d60f2eebaba Sweden (SE) | 53aa3e8e-d7c2-4a62-9d11-09c78d1d1a03 Poland (PL) | 7230619f-dcd1-4989-88ee-6b9f5340e73a Germany (DE) | 2c15b055-ec43-4341-906f-970bf1f82b0d Hungary (HU) | 2165d294-c079-4987-8d57-ae68465659d7 Belgium (BE) | 81c26c7c-95f2-4aa0-a511-d3cf43183e8f Sweden (SE) | e106a14b-d6e3-4e40-9899-cdb431f19829 Norway (NO) | 6ca7de89-07ae-41ff-95ef-2271888d89f1 Croatia (HR) | 00bfcc82-9a4a-4f99-aed5-ca1f51652605 Italy (IT) | 9636f2c2-2834-45cc-9711-eb1425f5db86 Germany (DE) | 778e1bf7-8b5a-4231-994b-b21b68ccad13 Netherlands (NL) | 0aa0701f-a055-4bd6-957c-a873410eff3b Greece (GR) | aeb7c507-dd8c-4841-9783-e061e607a50a Spain (ES) | 0f066d6a-7326-4375-aceb-d18e1c9c858f Finland (FI) | 96ec53b1-6fea-4844-9e02-927ef2d35e65 Portugal (PT) | 39f984af-2367-479f-8a08-62ec4098c6d0 Germany (DE) | f6e4194a-66bb-4054-a721-601c19192ef3 Denmark (DK) | 4562d14c-6c14-4119-96c0-3751c8015259 Germany (DE) | 8d36eb43-a090-4eba-938c-02e7decad674 Czech Republic (CZ) | a1b851cc-bbe7-4fc8-9c7e-3d37821a3304 Poland (PL) | 50853bbe-847c-449d-99b5-5c38d50d12e1 Estonia (EE) | f6186443-61dd-4415-95b1-671f480a3c38 Belgium (BE) | 51902d18-bb30-4b88-89cd-65ea2c4251aa Hungary (HU) | 42b4aec1-b92e-4666-ab62-8af690852234 Bulgaria (BG) | 0c529547-5e28-4a14-be43-2432d9121285 Poland (PL)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF80, AF96 (CN) Contactors | Environmental Product Declaration AF(S)80(B), AF(S)96(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, AC Contactor, AF(S)*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF(S)96-30-**-**, Made in France
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF*96-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
KC Certificate
KC Certificate AF80 4-pole Contactors
LR Certificate
LRS Certificate AF(S)09..(K) ... AF96 3 and 4-pole contactors and CA(L)4..(K), CAT4, CC4 auxiliary contact blocks
RMRS Certificate
RMRS Certificate AF09(S)...AF38 3-pole and 4-pole, AF40..96 3-pole contactors, screw and spring terminals
UL Certificate
UL-US Certificate of Compliance AF40(B)...80(B) 4-pole contactors | UL-CA Certificate of Compliance AF40(B)...80(B) 4-pole contactors
UL Listing Card
UL_E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.57 kg
Package Level 1 EAN
3471523133730
Package Level 2 Units
box 8 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
12.56 kg
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707460
E-Number (Sweden)
3210315
AF technology provides a wide control voltage range of 100-250 V, enabling flexible control inputs; this lowers panel wiring complexity and energy use, making it ideal for machines with fluctuating supply. Built-in surge protection reduces external protection components, lowering spare parts inventory and speeding commissioning while enhancing system reliability. The 4-pole, compact 90 mm width with TH35-15 DIN rail mounting offers space-efficient installation and straightforward panel integration across standard control cabinets. Main circuit voltages up to 1000 V and AC-1/AC-3 ratings up to 125 A (AC-1) and 80 A (AC-3) support robust motor starting for 37 kW at 400 V and similar line voltages, reducing system downtime. Coil consumption and power loss are minimized to improve energy efficiency, while screw terminals and a wide conductor range simplify wiring and future maintenance. Safety and compliance are ensured with IP20 coil protection and IP10 main terminals, plus broad standards coverage for global deployments. Compatibility with add-on auxiliary contact blocks and accessories enables scalable automation without reengineering panels, delivering cost-effective maintenance and easier retrofits for aging installations.

Get a Quick Quote for a ABB 1SBL397201R1300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL397201R1300? Enquire Now

FAQs

Install on a TH35-15 DIN rail as specified (35 x 15 mm). Allow 90 mm width clearance for the device, secure with suitable screws, and align the coil and main terminals for clear access. Use add-on auxiliary blocks if needed and follow tightening torques for safe, reliable connections.
Main circuit rated voltage is up to 1000 V with AC-1 current up to 125 A and AC-3 up to 80 A (at 60 °C). Control circuit voltage is 100-250 V (AC or DC) with coil consumption around 4 V·A holding and 8 W per pole at AC-1, enabling efficient operation across voltage variations.
Yes. The device is designed for high voltage mains up to 1000 V and supports motor control up to 37 kW at 400 V (AC-3), with robust switching performance and short-time withstand current capabilities. Its 4-pole configuration and wide voltage tolerance suit demanding industrial motor starters.
It complies with IEC/EN 60947-1 and 60947-4-1, UL 60335-2-40, and CSA standards, with CE/UKCA declarations for global deployment. Additional certifications include CCC, DNV, BV, LR, and more listed in the product declarations, ensuring broad regulatory acceptance.
Auxiliary contact blocks and add-on accessories are available to extend functionality. Regularly verify tightening torques: 6 N·m for main circuit, 1.2 N·m for control circuit, and inspect screw terminals (IP20 for coil, IP10 for main) to maintain reliable operation and minimize downtime.