ABB AF80 1SBL397201R1311 Block Contactor - UL/CE Certified

Part Number: 1SBL397201R1311
Manufacturer
ABB
Part number
1SBL397201R1311

Quick Summary

ABB AF80 block contactor is a four-pole switching device used to control motors in industrial automation. In unstable networks, control voltage variations can cause nuisance trips, so the AF80 accepts 100–250 V AC/DC and manages large voltage swings with confidence. The unit carries CE, UKCA, UL/CSA certifications and a DoC, ensuring global compliance for international installations. Its compact block design, expandable auxiliary contacts, and DIN-rail mounting simplify panel integration while delivering reliable operation and energy-efficient performance. By integrating surge protection and a wide operating range, it reduces wiring complexity, lowers panel energy consumption, and supports scalable machine designs across manufacturing floors.

Product Information

Extended Description

1SBL397201R1311 ABB: The AF80-40-11-13 is a 4 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Screw, switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
102 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.53 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to IEC 60947-5-1 690 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Power Loss
at 6 A per Pole 0.1 W | at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 7-1/2 A | (200 ... 208 V AC) Three Phase 25 A | (220 ... 240 V AC) Three Phase 30 A | (240 V AC) Single Phase 15 A | (440 ... 480 V AC) Three Phase 60 A | (550 ... 600 V AC) Three Phase 75 A
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations
3g Closed Position & 2g Open Position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
f1351ca3-d26f-4870-b029-a2dc58472f51 China (CN)
Simplified SCIP
9252ab9e-39fb-451a-94f2-95e55bbd9d4d Germany (DE) | 43e0102e-ecd4-41b6-a26c-11d4e4a01309 Spain (ES) | 8d030c11-8c22-42af-9fd2-676cc94eb323 Belgium (BE) | 5f528e90-d2a6-409b-9848-564dde4f897f Netherlands (NL) | d50fd189-cd5c-4617-b42f-d751ba23a0de Poland (PL) | 3489d646-c07f-48c3-8d47-fe8ed1e82a39 Hungary (HU) | ef424ccc-839c-477d-8960-6602495415e6 Greece (GR) | e9815de9-b6f8-4b7f-aca2-45311f0fb558 Estonia (EE) | c1004e38-1671-42e9-9277-bf9092e1c1ec Germany (DE) | 3c8d6c60-2e84-43ea-9ef6-97fdd323f16a Germany (DE) | 6e7438c6-637d-4c36-bd78-b0feb2676678 Denmark (DK) | 595ac30f-2633-4373-9c30-d09a0682e1ab Croatia (HR) | 41b9375b-f26b-45f2-a221-87e0ce4551ee Sweden (SE) | df2f0e9f-4eb4-4d0f-82c4-c48e903bba95 Germany (DE) | 60cd609b-160d-4382-afec-2bef8a823af6 France (FR) | 1962c824-ed77-4d7c-b8c4-ed76fdfa1238 Hungary (HU) | bf2929f3-f288-432c-87d7-44cd2e08f1a4 Belgium (BE) | 5a306de2-6d38-4623-8ab4-3ce5e1c3cd4c Germany (DE) | 3ac3e021-d0de-496f-8381-77fb46e2af76 Poland (PL) | e63a510e-2370-449c-bb57-857eecb0ba4f France (FR) | 5f38b723-b104-46dd-bd83-8edc5a55f6a7 Portugal (PT) | 749af534-0091-4b2c-a9a9-739651670414 Bulgaria (BG) | e63355e6-c7a1-4265-848e-95fadb7c93e8 Sweden (SE) | 04509545-0f4d-455c-ab3b-4e7fff56ddb9 Poland (PL) | a8242500-a3d1-42ac-b3b0-d2a366f1b418 Norway (NO) | 62382be7-ebee-4875-a0f6-b49bfe1f1bcb Finland (FI) | a02a0257-a6d2-4400-ab71-76155bbdef57 Czech Republic (CZ)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF80, AF96 (CN) Contactors | Environmental Product Declaration AF(S)80(B), AF(S)96(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, AC Contactor, AF(S)*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF(S)96-30-**-**, Made in France
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF*96-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
UL Certificate
UL-US Certificate of Compliance AF40(B)...80(B) 4-pole contactors | UL-CA Certificate of Compliance AF40(B)...80(B) 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
144 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Height
109 mm
Package Level 1 Gross Weight
1.69 kg
Package Level 1 EAN
3471523135635
Package Level 2 Units
box 8 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
13.52 kg
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Four-pole main circuit rated up to 125 A at 40 °C (AC-1) and 690 V, with higher-temperature ratings at 60–70 °C. This translates to robust motor control with minimal derating in hot industrial environments, improving uptime and reducing trips in conveyors and pumps. The AF80 technology provides a wide control voltage range of 100–250 V across AC, 50/60 Hz and DC operation, delivering stable operation despite supply fluctuations and enabling simpler control-panel design for diverse supply conditions. Built-in surge protection and a compact, block-type form factor reduce panel space and enable easy stacking with add-on auxiliary contact blocks, streamlining installation and maintenance in control cabinets. Auxiliary contacts (1 NO, 1 NC) offer local feedback and interlocking capabilities, enhancing safety interlocks and automated sequencing in CNC machines and packaging lines. DIN-rail mounting on TH35-15 (35 × 15 mm) plus screw-terminal connectivity for main and auxiliary circuits simplifies retrofits and new builds while maintaining reliable torque integrity. The product supports wide application across IEC/EN 60947-4-1, UL 60335-2-40, and CSA requirements, ensuring compliance during audits and in multinational operations. Energy efficiency is supported by low idle power (0.1 W per pole at 6 A) and manageable running losses (8 W per pole under rated AC-1), contributing to lower total cost of ownership over the equipment lifecycle. Compatibility with a wide range of conductor sizes (1/2 × 6 … 50 mm² for main, 0.75 … 2.5 mm² for auxiliary/control) and flexible termination options enable dependable wiring in medium- to high-power motor circuits. Industry practitioners will appreciate the ability to extend the control system with CA4/CAL4/CAT4 auxiliary contact blocks and to design modular, scalable motor control panels that adapt to changing process requirements.

Get a Quick Quote for a ABB 1SBL397201R1311

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL397201R1311? Enquire Now

FAQs