ABB AF80B-40-00-11 Block Contactor - 1000V / 125A CE UL
Part Number: 1SBL397261R1100
Quick Summary
ABB AF80B-40-00-11 is a 4-pole block contactor designed to reliably switch motors up to 37 kW at 400 V AC (AC-3) and control circuits up to 125 A. In demanding environments, wide control voltage variations can cause nuisance trips; this device supports control voltages from 24-60 V AC (50/60 Hz) and 20-60 V DC, reducing energy waste and improving uptime. Compliance with IEC/EN 60947-1, UL 60947-1 and CSA C22.2 ensures safe integration in global panels. With built-in surge protection and a compact block design, it’s easy to extend with add-on auxiliary blocks and accessories, lowering total cost of ownership. The unit mounts on TH35 DIN rails and uses screw terminals for flexible installation in compact control panels.
Product Information
Extended Description
1SBL397261R1100 ABB: The AF80B-40-00-11 is a 4 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
Motor control and protection for Rolling stock application_PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.49 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V | 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value DC 2 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 0 mm | Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Continuous Current Rating NEMA
0 A
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Shock and Vibration Withstand acc. to IEC 61373
Category 1, Class B
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)80(B), AF(S)96(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, AC Contactor, AF(S)*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF(S)96-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09 ... AF38(Z)B..(K), AF40B ... AF96B 3 and 4-pole contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09 ... AF38(Z)B..(K), AF40B ... AF96B 3 and 4-pole contactors
UL Certificate
UL-US Certificate of Compliance AF40(B)...80(B) 4-pole contactors | UL-CA Certificate of Compliance AF40(B)...80(B) 4-pole contactors
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.62 kg
Package Level 1 EAN
3471523025417
Package Level 2 Units
box 8 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
12.96 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
Feature: Four-pole AF80B-40-00-11 design enables robust motor control for high-power loads. Business impact: Handles motors up to 37 kW at 400 V AC (AC-3) with reliable switching, reducing downtime and improving line efficiency. Application: Ideal for conveyors, pumps, and fans in industrial automation. Feature: Wide coil voltage range (24-60 V AC, 50/60 Hz; 20-60 V DC) minimizes control panel variations. Business impact: Fewer nuisance trips and energy waste, enabling stable operations in networks with voltage fluctuations. Application: Critical in automation panels with variable supply conditions. Feature: Built-in surge protection and compact block design reduce external protection needs and save panel space. Business impact: Lower BOM costs and easier certification, with quicker commissioning. Application: Suitable for space-constrained control enclosures. Feature: AF technology and block-type design allow straightforward expansion with auxiliary contact blocks. Business impact: Scales from simple control to complex logic without replacing the base device. Application: Retrofit projects and modular machine design. Feature: Low coil consumption and efficient power loss characteristics (4 V·A hold; 2 W DC; 8 W AC-1 per pole; 3.2 W AC-3 per pole). Business impact: Reduced heat and energy use, lowering operating costs over the device lifecycle. Application: Continuous operation in temperature-controlled industrial environments. Feature: DIN-rail mounting (TH35-15) and screw-terminal connections. Business impact: Easy integration into existing panels with minimal tooling and flexible wiring. Application: Standardized installation in new builds and upgrades.
Get a Quick Quote for a ABB 1SBL397261R1100
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL397261R1100?
Enquire Now
FAQs
The AF80B-40-00-11 supports TH35-15 DIN-rail mounting and can be screwed to panels with 2 x M4 or 2 x M6 screws placed diagonally. It uses screw terminals for both main and control circuits, with suitable wire sizes (flexible ferrule up to 50 mm² for main, 0.75-2.5 mm² for control). Wire stripping lengths are 17 mm for main, 10 mm for control, and 0 mm for auxiliary. This combination enables straightforward installation in compact automation enclosures.
Main circuit rated up to 1000 V with AC-1 current up to 125 A (at 690 V, 60 °C), and AC-3 current up to 80 A (415–690 V) or 49–65 A at various voltages. The device can switch loads up to 37 kW at 380–400 V (AC-3). It supports a maximum electrical switching frequency of 600 cycles per hour (AC-1) and 3600 cycles per hour mechanically, ensuring suitability for cycle-intensive applications.
Yes. ABB lists data sheets for rolling stock applications, and the AF80B family is designed to meet requirements applicable to railway environments. Its wide control voltage tolerance, surge protection, and robust IEC/UL/CSA certification enable reliable motor control in rolling stock and other demanding industrial settings.
The AF80B-40-00-11 complies with IEC/EN 60947-1 and IEC/EN 60947-4-1, UL 60947-1 and UL 60947-4-1, CSA C22.2 Nos., and is CE/UKCA-marked. It also aligns with applicable parts of IEC 60077 and EN 50155 where relevant. These certifications support safe integration in global panels and help with regulatory compliance during audits.
The wide control voltage range reduces panel energy consumption and minimizes chiller or boiler start-up surges. Built-in surge protection lowers external protection requirements, while low coil consumption (4 V·A at 50/60 Hz, 2 W DC) reduces heat and energy use. Combined with modular accessories and compact design, this translates to lower maintenance costs and faster commissioning, delivering favorable return on investment over the device lifecycle.