Block Contactor ABB 1SBL397501R1400 provides reliable motor control for industrial panel applications. In environments with voltage variation and panel energy waste, stable operation is essential to avoid costly downtime. This device carries CE, UKCA, and UL/CSA approvals, plus IEC 60947-4-1/60947-1 compliance, delivering proven safety and interoperability across markets. With AF technology and a wide control voltage range of 250–500 V, it includes built‑in surge protection to reduce panel complexity and energy consumption. The compact four‑pole design supports easy extension with add‑on auxiliary contact blocks and accessories, helping standardize control schemes across multiple lineups and simplify maintenance.
Product Information
Extended Description
1SBL397501R1400 ABB: The AF80-22-00-14 is a 4 pole - 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
Installation instructions AF(C)40(B)...80(B)-40/22 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
116 mm
Product Net Height
125.5 mm
Product Net Weight
1.44 kg
Number of Main Contacts NO
2
Number of Main Contacts NC
2
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Control Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 125 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 80 A | (440 V) 60 °C 80 A | (500 V) 60 °C 65 A | (690 V) 60 °C 49 A | (1000 V) 60 °C 25 A | (380 / 400 V) 60 °C 80 A | (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 45 kW | (440 V) 45 kW | (500 V) 45 kW | (690 V) 45 kW | (1000 V) 35 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Average Holding Value 50 / 60 Hz 4 V·A | Average Holding Value 50 Hz 4 V·A | Average Holding Value 60 Hz 4 V·A | Average Holding Value DC 2 W | Average Holding Value, from Warm State 2 W
Power Loss
at Rated Operating Conditions AC-1 per Pole 8 W | at Rated Operating Conditions AC-3 per Pole 3.2 W
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid Stranded 1x 6 ... 70 mm² | Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid Solid 1/2x 1 ... 2.5 mm² | Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Pozidriv PZ
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 105 A
Connecting Capacity Main Circuit UL/CSA
Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWG | Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 7-1/2 A | (200 ... 208 V AC) Three Phase 25 A | (220 ... 240 V AC) Three Phase 30 A | (240 V AC) Single Phase 15 A | (440 ... 480 V AC) Three Phase 60 A | (550 ... 600 V AC) Three Phase 75 A
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations
3g Closed Position & 2g Open Position 5 ... 300 Hz
Pollution Degree
3
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
0412dbc4-9f13-420f-a66f-130229e074c4 China (CN)
Simplified SCIP
07ec08c2-8bbe-4079-8ab3-6246c6c44db3 Sweden (SE) | 056fc8e6-a58f-424d-9bdb-56f4e5124870 Germany (DE) | eeefba10-734f-4635-9a28-83ff5af23873 Poland (PL) | a9ab55c2-ccfc-41ee-b7b0-75e08c9e7855 Germany (DE) | 61bc6b8a-2166-48bd-b9e1-799474d05b33 Spain (ES) | 6b3d2be9-42f1-4eb6-a142-3697dc63aa5a Denmark (DK) | 5cc9974e-e4ce-4465-818d-2b9aad54a5fe Germany (DE) | cc745a72-67aa-452d-b95c-b0e0fb996d8d Croatia (HR) | 2a903385-7387-482a-bb40-a048b9b5278d Czech Republic (CZ) | 950f069c-6d27-432e-a706-80d1104d77d8 Belgium (BE) | b2e4553a-8ef7-430c-9021-cef97ef3c644 Germany (DE) | da289159-e0d5-4f99-8e8d-33587cda34d5 Sweden (SE) | 3605bb03-afe0-4284-a4ef-aaa2fedde7c8 France (FR) | a4c843a0-f36f-43dd-8ff5-a465ceee8815 France (FR) | fedcc2b0-3b41-4df6-af9e-61d25d987fc4 Greece (GR) | 34e1d880-c9af-4d01-810f-407b4d5f32a9 Belgium (BE) | cea959e3-ca27-4f83-a8eb-151a58b727bc Finland (FI) | 3cda8f7c-ee1d-40f7-a01f-36d9d9b7ed3c Estonia (EE) | 3fe4d4fe-d9e8-45af-b636-9c195a6e6ca7 Bulgaria (BG) | 71fce868-006e-40e1-a4fc-068960f0a769 Hungary (HU) | f9f566fc-645f-440b-bbcc-44760eb0e339 Norway (NO) | 4ef05627-8413-48a3-885e-48cdb631dcb2 Poland (PL) | e6e9c4f5-1e1d-43f6-832a-6e4fd92d3641 Poland (PL) | a2722503-eb5a-4f4a-8a27-7eb22368cfc4 Hungary (HU) | 3433e380-9908-4dd7-a84f-3113197d1daf Netherlands (NL) | 44bdd1da-c911-4203-9a96-89cb5a5841f7 Portugal (PT) | 34ca1edd-8c84-44ed-974d-bbacee08501a Germany (DE)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
End Of Life Disassembling Instructions
End of life instruction AF(S)40/52/65/80/96(B)(RT) Contactors
Environmental Product Declaration - EPD
Environmental Product Declaration AF80, AF96 (CN) Contactors | Environmental Product Declaration AF(S)80(B), AF(S)96(B) (FR)
Sustainable Material Content in Packaging (wt. %)
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 28.2 %
A2L Certificate – UL
UL-US Certificate of Compliance AF40 ... AF96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AF40 ... AF96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ABS Certificate
ABS Certificate, AF(S)09 to AF(S)96 contactors, NF contactor relays and CA4, CC4, CAL4, CAT4 auxiliary contact blocks, TEF4 electronic timers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AF(S)80(B), AF(S)96(B) 3 and 4-pole contactors
CCC Certificate
CQC Certificate, AC Contactor, AF(S)*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF(S)96-30-**-**, Made in France
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF*80-30-**-**, AF80-40-**-**, AF80-22-**-**, AF*96-30-**-**, Made in France
Declaration of Conformity - CE
EU Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AF09, AF16, AF26, AF38, AF40, AF52, AF80, 4-pole Contactors
DNV Certificate
DNV Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
KC Certificate
KC Certificate AF80 4-pole Contactors
UL Certificate
UL-US Certificate of Compliance AF40(B)...80(B) 4-pole contactors | UL-CA Certificate of Compliance AF40(B)...80(B) 4-pole contactors
UL Listing Card
UL_E312527
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Height
103 mm
Package Level 1 Gross Weight
1.57 kg
Package Level 1 EAN
3471523133945
Package Level 2 Units
box 8 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
300 mm
Package Level 2 Gross Weight
12.56 kg
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707456
E-Number (Sweden)
3210353
Feature synthesis follows a practical pattern: Four-pole block construction with two main NO and two NC contacts provides robust motor switching in a compact footprint, delivering reliable performance in demanding lines while simplifying wiring. This translates to tangible business impact: fewer components, faster installations, and reduced field failures, making it ideal for packaging lines and conveyors where downtime costs matter. The wide control voltage range of 250–500 V AC/ DC minimizes panel redesigns during voltage fluctuations and enables flexible drive integration, reducing engineering time and inventory complexity. Built‑in surge protection lowers external protection needs and extends device life in unstable networks, decreasing maintenance costs and unplanned outages. DIN rail mounting TH35‑15 and IP20 coil protection with IP10 main terminals enable quick, compliant panel assembly and safe operation in machine enclosures. The device handles AC‑1 up to 125 A and AC‑3 up to 80 A at relevant voltages, with low power loss per pole, supporting energy‑efficient applications. Compatibility with add‑on auxiliary contact blocks and accessories allows scalable control logic without replacing the base unit, offering a future‑proof solution for evolving control schemes across multiple lines. Industry context shows that modular, compliant contactors streamline lifecycle management and spare part alignment, improving procurement predictability and total cost of ownership.
Get a Quick Quote for a ABB 1SBL397501R1400
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL397501R1400?
Enquire Now
FAQs
This contactor supports TH35-15 DIN rail mounting for quick installation and a pair of diagonally placed M4 or M6 screws for screw mounting. The DIN rail option simplifies enclosure design, speeds assembly, and ensures reliable vibrational performance in automated systems.
Rated Operational Current AC-1 at 690 V is 125 A (60 °C) and 105 A (60 °C) at 690 V, with 90 A at 70 °C. For AC-3, ratings include up to 80 A at 415–500 V (varies with voltage). Power ratings reach 45 kW in typical AC-3 scenarios, enabling robust motor control.
Yes. The device supports 400 V three-phase systems and delivers motor control up to 37 kW (AC-3) in common European configurations, with a control voltage range of 250–500 V and built‑in surge protection to maintain performance under fluctuating supply.
The product carries CE and UKCA marks, UL/CSA listings, and IEC/EN compliance for 60947-4-1 and 60947-1, among others. It also aligns with UL 60335-2-40 family safety requirements, CB certificates, and various global registrations to support compliant procurement and installation worldwide.
AF technology provides a wide control voltage tolerance, reducing panel energy waste and supply variation issues. Built‑in surge protection lowers the need for external protection devices, decreasing panel complexity and maintenance. Together, these features improve uptime, extend component life, and lower lifetime operating costs in automated lines.