ABB 1SBL401001R4211 Block Contactor - UL/CSA Certified

Part Number: 1SBL401001R4211
Manufacturer
ABB
Part number
1SBL401001R4211

Quick Summary

ABB 1SBL401001R4211 Block Contactor is a 3-pole power switch for motor control. It enables reliable operation while reducing downtime and wiring complexity in compact control panels. Certified to CE and UL/CSA standards, it also features IP20 protection on auxiliary terminals and IP10 on main terminals for safer enclosure use. Designed for DIN-rail mounting and compatible with 230-240 V AC 50 Hz or 277 V AC 60 Hz control voltages, this device supports AC-1 and AC-3 applications with high current ratings, delivering scalable performance for modern machines and lines. The combination of standardized dimensions, screw terminals, and accessory options makes installation faster and maintenance straightforward.

Product Information

Extended Description

1SBL401001R4211 ABB: The AFC96-30-11-42 is a 3-pole - 1000 V IEC or 600 V UL contactor with 1 N.O + 1 N.C built-in auxiliary contact and Screw terminals, mainly controlling power circuits up to 130 A (IEC AC-1) or 115 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 230 ... 240 V AC 50 Hz / 277 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
87 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.25 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 130 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 96 A | (220 / 230 / 240 V) 60 °C 96 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 96 A | (220 / 230 / 240 V) 60 °C 96 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Operational Power AC-6b (Pe)
(400 / 415 V) 40 °C, 50 / 60 Hz 60 kvar | (400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar | (400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar | (500 / 550 V), 40 °C, 50 / 60 Hz 75 kvar | (500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar | (500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar | (690 V) 40 °C, 50 / 60 Hz 82 kvar | (690 V) 55 °C, 50 / 60 Hz 82 kvar | (690 V) 70 °C, 50 / 60 Hz 75 kvar
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 277 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8.2 W | at Rated Operating Conditions AC-3 per Pole 4.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 21 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 3 ... 17 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 115 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (240 V AC) Single Phase 20 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 88 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C | Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 g | Closed, Shock Direction: B1 25 g | Closed, Shock Direction: B2 15 g | Closed, Shock Direction: C1 25 g | Closed, Shock Direction: C2 25 g | Open, Shock Direction: B1 5 g
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AFC40 ... AFC96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AFC40 ... AFC96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
cULus Certificate
UL-US-L312527-1141-10303102-2
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US-2206508-0 | UL-CA-2206439-0
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.37 kg
Package Level 1 EAN
3471523023574
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3-pole Block Contactor with built-in 1 NO + 1 NC auxiliary contact. Business impact: enables compact yet robust control of power circuits up to 130 A (IEC AC-1), reducing space requirements and wiring complexity in control panels. Application: suitable for AC motor control in conveyors and processing lines with IEC/EN 60947-4-1 compliance. Feature: Coil voltages 230-240 V AC at 50 Hz and 277 V AC at 60 Hz. Business impact: flexible control interfaces for global equipment fleets, lowering wiring variants and spare part needs. Application: supports 230/240 V control schemes and higher voltage 277 V systems in mixed-voltage installations. Feature: Rated operational currents AC-1 and AC-3 across voltage ranges (Ie up to 130 A AC-1 at 690 V, 96 A AC-3 at 415-440-380/400 V, 96 A at 220/230/240 V). Business impact: clear current headroom for standard motor starters, enabling safer startup and reduced wear. Application: motor drive and general power switching in heavy plant equipment. Feature: DIN rail mounting TH35-15 or TH35-7.5 and screw terminals. Business impact: rapid, tool-friendly installation with reliable mechanical retention and straightforward field wiring. Application: best-suited for panel builders and machine assemblers integrating control gear. Feature: Protective ratings IP20 on auxiliary terminals and IP10 on main terminals. Business impact: improved protection against dust ingress and incidental contact in standard environments, lowering field failure risk. Application: suitable for indoor industrial enclosures with moderate contamination. Feature: Energy and performance efficiency with defined coil and switching characteristics (8.2 W AC-1 per pole; 4.5 W AC-3 per pole; operate times in the 3–22 ms range). Business impact: lower heat generation, reduced energy costs, and predictable response times for reliable machine sequencing. Application: panel-mounted control units where precise timing and energy efficiency matter.

Get a Quick Quote for a ABB 1SBL401001R4211

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL401001R4211? Enquire Now

FAQs

The contactor supports DIN rail mounting on TH35-15 or TH35-7.5, with additional option for screw mounting using 2 x M4 or 2 x M6 screws diagonally. This offers flexible installation in compact panels and standard enclosures.
AC-1 rated current is up to 130 A at 690 V and 40 °C (with lower values at higher temperatures: 105 A at 690 V/60 °C and 90 A at 690 V/70 °C). AC-3 rated current is 96 A at 415–440 V/60 °C, 96 A at 380–400 V/60 °C, and 96 A at 220–240 V/60 °C, with reductions at higher voltages as specified.
Yes. The coil control voltage is 230-240 V AC at 50 Hz and 277 V AC at 60 Hz, covering typical North American and European control networks and enabling flexible integration with existing control cabinets.
The contactor carries CE and UL/CSA certifications, plus CB, DNV, and RINA declarations. It also aligns with UL US/CA standards and provides DoCs for CE, UKCA, and related compliance as listed in the product documentation.
Install on a stable DIN rail to minimize vibration, use the indicated screw terminal torque (Main 6 N·m; Auxiliary 1.2 N·m; Control 1.2 N·m), and ensure proper wire sizing (Main 6–70 mm², Auxiliary 0.75–2.5 mm²). Regularly inspect connections and keep within IP20/IP10 protection guidelines for reliable operation in typical industrial environments.