ABB 1SBL401001R8111 Block Contactor - UL/CSA 1000V
Part Number: 1SBL401001R8111
Quick Summary
The ABB 1SBL401001R8111 Block Contactor is a 3-pole power switch for motor and control circuits. In busy industrial environments, space constraints and wiring complexity can hinder uptime unless you rely on a compact, modular solution. This device complies with IEC/EN 60947-1, IEC/EN 60947-4-1 and UL/CSA safety standards, with auxiliary and main terminal configurations that ensure robust protection. Its built-in 1 N.O + 1 N.C auxiliary contact and wide accessory range minimize wiring errors, reduce spare parts inventory, and simplify maintenance. For buyers, the combination of DIN rail mounting, screw-terminals, and scalable design translates to faster installation and lower total cost of ownership, while delivering proven reliability in demanding applications.
Product Information
Extended Description
1SBL401001R8111 ABB: The AFC96-30-11-81 is a 3-pole - 1000 V IEC or 600 V UL contactor with 1 N.O + 1 N.C built-in auxiliary contact and Screw terminals, mainly controlling power circuits up to 130 A (IEC AC-1) or 115 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 24 V AC 50 Hz / 24 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
87 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.25 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 130 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 96 A | (220 / 230 / 240 V) 60 °C 96 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 96 A | (220 / 230 / 240 V) 60 °C 96 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (48 V) 2.8 A / 134 W | (72 V) 1 A / 72 W | (110 V) 0.55 A / 60 W | (125 V) 0.55 A / 69 W | (220 V) 0.27 A / 60 W | (250 V) 0.27 A / 68 W | (400 V) 0.15 A / 60 W | (500 V) 0.13 A / 65 W | (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Operational Power AC-6b (Pe)
(400 / 415 V) 40 °C, 50 / 60 Hz 60 kvar | (400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar | (400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar | (500 / 550 V), 40 °C, 50 / 60 Hz 75 kvar | (500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar | (500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar | (690 V) 40 °C, 50 / 60 Hz 82 kvar | (690 V) 55 °C, 50 / 60 Hz 82 kvar | (690 V) 70 °C, 50 / 60 Hz 75 kvar
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8.2 W | at Rated Operating Conditions AC-3 per Pole 4.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 21 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 3 ... 17 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Auxiliary Circuit 1.2 N·m | Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 115 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (240 V AC) Single Phase 20 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lb | Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 88 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 g | Closed, Shock Direction: B1 25 g | Closed, Shock Direction: B2 15 g | Closed, Shock Direction: C1 25 g | Closed, Shock Direction: C2 25 g | Open, Shock Direction: B1 5 g
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AFC40 ... AFC96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AFC40 ... AFC96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
cULus Certificate
UL-US-L312527-1141-10303102-2
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US-2206508-0 | UL-CA-2206439-0
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.37 kg
Package Level 1 EAN
3471523019577
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: 3-pole, 1000 V rated main circuit provides high-voltage handling for large control loads, reducing device count and improving reliability in motor control. This enables a more compact control panel design and lowers wiring complexity in manufacturing lines. Application: drives and conveyor systems requiring solid switching performance at up to IEC AC-1 current levels up to 130 A. Feature → Built-in 1 N.O + 1 N.C auxiliary contact simplifies control logic, enabling straightforward interlock schemes and reduced external relay count in automation architectures. Application: PLC interlocks and timer-based start/stop sequences in packaging lines. Feature → 24 V AC control coil (50/60 Hz) with defined coil consumption (holding and pull-in), delivering predictable energization profiles and easier stock management. Application: control circuits for machine controls and relay interfaces across standard automation platforms. Feature → Block contactor with block-type design and compatibility with add-on auxiliary contact blocks and accessories, offering scalable expansion. Business Impact: modularity lowers lifecycle costs and supports future line upgrades without replacing the base unit. Application: upgradeable control panels in bottling lines and material handling systems. Feature → Wide electrical ratings (Ie AC-1 up to 130 A, AC-3 up to 96 A at various voltages) and high breaking capacity, ensuring reliable switching of motors and power circuits. Business Impact: reduces downtime due to contact wear and nuisance tripping, improving overall line efficiency. Application: direct motor start and control for fans, pumps, and conveyors in process industries. Feature → DIN rail mounting (TH35-15) and screw-terminals for both main and auxiliary circuits. Application: fast, secure installation in standard electrical panels with straightforward field maintenance. Feature → Comprehensive environmental and safety specs (operating temp -40 to 70 C, altitude up to 3000 m, IP20/ IP10 terminations). Application: suitable for harsh factory settings and elevated installations. Feature → Energy and efficiency metrics (8.2 W per pole AC-1, 4.5 W per pole AC-3; 3600 M switching frequency mechanical, 600 cycles electrical). Business Impact: supports better energy budgeting and longer product life under continuous operation. Feature → Broad certifications (IEC/EN,UL/CSA, CE DoC, UL/CSA listings). Application: enables global procurement with regulatory compliance across markets.
Get a Quick Quote for a ABB 1SBL401001R8111
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL401001R8111?
Enquire Now
FAQs
The device is designed for TH35-15 DIN rail mounting and features screw terminals for both main and auxiliary circuits. Wire flexible or rigid conductors up to 70 mm² for the main circuit and 2.5 mm² for auxiliary control circuits. Follow the 17 mm main circuit lead length and 10 mm control circuit lead length to ensure proper termination and optimal clamping force.
Main circuit rated at 1000 V with IEC AC-1 up to 130 A, AC-3 up to 96 A at 60°C, and a maximum breaking capacity suitable for 440–690 V ranges. It supports a 3P configuration with 1 N.O + 1 N.C auxiliary contact, making it suitable for motor starting and switching within typical industrial loads.
Yes. The coil operates at 24 V AC for 50/60 Hz, with measured coil power consumption (holding and pull-in) that aligns with standard control circuits. This compatibility simplifies stock management and eases integration with most PLCs and control relays used in automation panels.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL/CSA listings, and CE documentation. It also references UL 60335-2-40 compatibility for household appliance safety and other certificates (BV, CB, CULUS family) enabling global sourcing and cross-market approvals.
Modular auxiliary blocks and a robust block-contactor design minimize spare-part variety and simplify maintenance. Built-in auxiliary contacts reduce external relays, lowering panel complexity and installation time. With low coil power and favorable thermal performance, operating costs improve while downtime risks decrease in continuous production lines.