ABB 1SBL401001R8500 Block Contactor - IEC/UL 1000 V

Part Number: 1SBL401001R8500
Manufacturer
ABB
Part number
1SBL401001R8500

Quick Summary

ABB 1SBL401001R8500 Block Contactor is a three-pole device for controlling power circuits up to 130 A in industrial automation. In demanding installations, space constraints, coil energization stability, and the need for fast, reliable switching are common challenges. It complies with IEC/EN 60947-4-1 and UL 60947-4-1, and carries CSA/CUL listings along with CE/UKCA declarations to support global compliance. Pairing this unit with the AF platform and compatible accessories reduces wiring complexity and maintenance while enabling scalable control of motors, conveyors, and pumps.

Product Information

Extended Description

1SBL401001R8500 ABB: The AFC96-30-00-85 is a 3-pole - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 130 A (IEC AC-1) or 115 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 380 ... 400 V AC 50 Hz / 400 ... 415 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100219C0201 AFC contactors for AC control applications_Catalog PDF
Instructions and Manuals
Installation instructions AF(C)40(B)...96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories
Instructions and Manuals (Part 2)
Contactors and Overload relays guide
Product Net Width
70 mm
Product Net Depth / Length
119.5 mm
Product Net Height
116 mm
Product Net Weight
1.21 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L
Rated Operational Voltage
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 130 A | (690 V) 60 °C 105 A | (690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 96 A | (220 / 230 / 240 V) 60 °C 96 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 96 A | (440 V) 60 °C 96 A | (500 V) 60 °C 80 A | (690 V) 60 °C 57 A | (380 / 400 V) 60 °C 96 A | (220 / 230 / 240 V) 60 °C 96 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Operational Power AC-6b (Pe)
(400 / 415 V) 40 °C, 50 / 60 Hz 60 kvar | (400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar | (400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar | (500 / 550 V), 40 °C, 50 / 60 Hz 75 kvar | (500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar | (500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar | (690 V) 40 °C, 50 / 60 Hz 82 kvar | (690 V) 55 °C, 50 / 60 Hz 82 kvar | (690 V) 70 °C, 50 / 60 Hz 75 kvar
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 380 ... 400 V | 60 Hz 400 ... 415 V
Coil Consumption
Average Holding Value 50 / 60 Hz 20 V·A | Average Pull-in Value 50 Hz 236 V·A | Average Pull-in Value 60 Hz 260 V·A
Power Loss
at Rated Operating Conditions AC-1 per Pole 8.2 W | at Rated Operating Conditions AC-3 per Pole 4.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 21 ms | Between Coil De-energization and NO Contact Opening 5 ... 16 ms | Between Coil Energization and NC Contact Opening 3 ... 17 ms | Between Coil Energization and NO Contact Closing 7 ... 22 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 6 ... 50 mm² | Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm² | Rigid 1x 6 ... 70 mm² | Rigid 2x 6 ... 50 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mm | Main Circuit 17 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver
Main Circuit 4 | Main Circuit Hexagon | Control Circuit 5.5 | Control Circuit Slot
Tightening Torque
Control Circuit 1.2 N·m | Main Circuit 6 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 115 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (240 V AC) Single Phase 20 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Control Circuit 11 in·lb | Main Circuit 53 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 88 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: A 25 g | Closed, Shock Direction: B1 25 g | Closed, Shock Direction: B2 15 g | Closed, Shock Direction: C1 25 g | Closed, Shock Direction: C2 25 g | Open, Shock Direction: B1 5 g
Pollution Degree
3
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
A2L Certificate – UL
UL-US Certificate of Compliance AFC40 ... AFC96 3-pole contactors - UL 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers | UL-CA Certificate of Compliance AFC40 ... AFC96 3-pole contactors - CSA C22.2 No. 60335-2-40 Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
BV Certificate
BV_2634H36994B1
CB Certificate
CB Certificate AFC80 and AFC96 3-and 4-pole contactors
cULus Certificate
UL-US-L312527-1141-10303102-2
Declaration of Conformity - CE
EU Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
Declaration of Conformity - UKCA
UK Declaration of Conformity AFC09..(K) ... AFC96 3-pole Contactors
DNV Certificate
DNV Certificate AFC09...96 3-pole & AFC09...80 4-pole contactors with screw, push-in terminals
RINA Certificate
Rina Certificate for AFC09...AFC96 3 pole and 4 pole contactors, NFC relays ,screw and spring terminals
UL Certificate
UL-US-2206508-0 | UL-CA-2206439-0
Package Level 1 Units
box 1 piece
Package Level 1 Width
146.5 mm
Package Level 1 Depth / Length
96.5 mm
Package Level 1 Height
146.5 mm
Package Level 1 Gross Weight
1.33 kg
Package Level 1 EAN
3471523019607
Package Level 3 Units
192 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3-pole, block-type design with screw terminals delivers robust main-circuit connections for motors and power loads, reducing loose connections and maintenance time in control cabinets. This enables predictable startup behavior and improved uptime in applications such as conveyors and pumps where reliability translates to lower downtime and costs. Feature → Business Impact → Application: Coil voltage versatility (380-400 V AC 50 Hz or 400-415 V AC 60 Hz) allows seamless integration with regional control systems, minimizing wiring changes and facilitating cross-site deployments. Application: Industrial automation panels in factories with mixed voltage supplies. Feature → Business Impact → Application: Rated operational currents (Ie) up to 130 A AC-1 and 96 A AC-3 across multiple voltages provide precise sizing for motor loads, reducing overdesign and equipment wear. Application: Starter circuits for fans, pumps, and small motors. Feature → Business Impact → Application: Low power loss per pole (8.2 W AC-1, 4.5 W AC-3) and fast operate times (7–22 ms) improve energy efficiency and system responsiveness. Application: High-speed motor control and energy management in packaging lines. Feature → Business Impact → Application: DIN rail mounting (TH35-15) and screw terminals simplify installation and field upgrades, supporting rapid deployment and serviceability. Application: Panel builders seeking modular, scalable control solutions. Feature → Business Impact → Application: Compatibility with auxiliary contact blocks and a wide accessory range enables tailored protection, signaling, and integration with PLCs or safety circuits. Application: Modular control systems for OEM equipment.

Get a Quick Quote for a ABB 1SBL401001R8500

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL401001R8500? Enquire Now

FAQs

This block contactor is designed within the AF platform and supports add-on auxiliary contact blocks and a wide range of accessories. It can be expanded with auxiliary blocks, signaling options, and protective devices to suit motor starter and control panel needs, while maintaining screw-terminal connections and DIN-rail mounting for easy installation and serviceability.
The device provides an IEC AC-1 rating up to 130 A and AC-3/AC-3e ratings around 96 A at typical installation voltages (415–440–500 V, 380–400 V). Ratings vary with ambient temperature (40 °C, 60 °C, 70 °C) and voltage, so sizing should consider load type and corresponding duty class to ensure reliable operation.
Yes. It carries UL/CSA listings (UL-US and UL-CA), adheres to UL 60947-4-1, CSA C22.2 No. 60947-4-1, and provides CE and UKCA declarations. It also aligns with related certificates (CB, BV, DNV, RINA) to support safe installation and regulatory compliance across multiple regions.
It mounts on standard TH35-15 DIN rails and uses screw terminals for the main circuit. The control circuit accepts flexible ferrules and rigid conductors within specified cross-sections. Wire stripping is 10 mm for control and 17 mm for the main circuit, with auxiliary terminals rated IP20 and main terminals IP10, aiding reliable field wiring.
Operate from -40 to 70 °C with a maximum altitude of 3000 m (no derating). The unit meets Category B climatic withstands per IEC 60947-1 Annex Q and provides IP20 (auxiliary/coil) and IP10 (main terminals) protection. Fan walls, dust, and vibration considerations should still follow installation guidelines to maintain longevity.