ABB 1SBL411074R2600 Block Contactor - UL/CE 690V
Part Number: 1SBL411074R2600
Quick Summary
Block Contactor ABB 1SBL411074R2600 safely controls 3-phase motors and power circuits up to 690 V AC in demanding industrial environments. Engineers often face downtime and mis-sizing when selecting motor starters, so precise ratings and reliable coil voltages are essential to prevent nuisance trips and shortened equipment life. This ABB model demonstrates CE and UL/CSA compliance, plus IP20 coil terminals and robust thermal ratings to support safe integration in control panels. Its compact footprint and CAD-ready data streamline installation and maintenance, delivering value across manufacturing lines, packaging systems, and material-handling equipment. Technical reliability, easy sourcing, and documented performance help you design for long-term uptime and predictable ROI.
Product Information
Extended Description
1SBL411074R2600 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 80 A | (440 V) 55 °C 70 A | (500 V) 55 °C 65 A | (690 V) 55 °C 46 A | (380 / 400 V) 55 °C 80 A | (220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW | (440 V) 40 kW | (500 V) 45 kW | (690 V) 40 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 105 V | 60 Hz 110 ... 127 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522407269
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AX50–AX80 block contactor family provides 3 main NO contacts and 690 V AC main circuit voltage, enabling reliable control of 3-phase motors in conveyors, pumps, and machine tools. This translates to a straightforward installation with proven electrical endurance (Ith 125 A) and predictable switching performance (AC-1 600 cycles/hour, AC-3 600 cycles/hour). The coil operates at 50 Hz 105 V or 60 Hz 110–127 V, ensuring compatibility with common power rails and simplifying panel design. The compact dimensions (82 mm W × 110 mm D × 108 mm H) and weight (1.05 kg) support tight panel layouts and lower enclosure costs. Add-on auxiliary contact blocks (optional) simplify expansion without redesigning the control circuit. With screw terminals and tightening torques of 1 N·m (control) and 4 N·m (main), installation is fast and repeatable, reducing field wiring errors. Industry-standard CAD data (2D/3D) accelerates engineering workflows and procurement alignment.
Get a Quick Quote for a ABB 1SBL411074R2600
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL411074R2600?
Enquire Now
FAQs
This contactor uses screw terminals with a control-torque of 1 N·m and main-circuit torque of 4 N·m, simplifying panel wiring and ensuring secure connections in harsh environments. Its compact 82 mm width and 110 mm depth fit standard control enclosures, while the provision for add-on auxiliary contact blocks enables future expansion without reworking the control circuit. Ensure adequate ventilation and clean, dry mounting to maintain IP20 protection during operation.
For AC-3 operation at 690 V, the device provides 46–80 A depending on voltage and ambient temperature, with a rated power up to 45 kW in typical configurations and a maximum short-time withstand current (Icw) of up to 1000 A for brief faults. The unit is rated for 50 Hz 105 V or 60 Hz 110–127 V control voltage, and it supports 125 A Ith with 3 NO main contacts, making it suitable for compact motor starters in medium horsepower drives.
Yes. The AX50–AX80 family includes EU declarations of conformity (CE) and UL/CSA listings, along with other certifications such as CCC and CQC in various markets. This combination supports compliance across global installations, simplifies supplier qualification, and aligns with your internal procurement standards for motor-control devices used in industrial automation.
Yes. The AX50–AX80 block contactors are designed to accommodate add-on auxiliary contact blocks and side-mount configurations, enabling flexible control-circuit expansion without replacing the main device. This is particularly beneficial for applications requiring multiple interlocks or feedback signals within a compact control panel.
Individual units ship as box 1 piece with dimensions around 102 mm × 143 mm × 152 mm and a gross weight of 1.16 kg. For bulk, level-2 packaging groups 10 pieces per carton with dimensions ~240 mm × 295 mm × 145 mm and a gross weight of 11.6 kg, facilitating efficient palletized transport and stocking. The unit ships with a standard EAN 3471522407269 for traceability.