ABB 1SBL411074R2611 Block Contactor - 690V 125A
Part Number: 1SBL411074R2611
Quick Summary
Block Contactor ABB 1SBL411074R2611 is designed to reliably switch 3-phase motors and power circuits up to 690 V AC in industrial automation. End users often struggle with coil-voltage compatibility and panel space; this unit combines a compact block design with screw terminals for straightforward installation. It carries CE conformity, UL/CSA approvals, and CCC/CB declarations, supporting compliance across regions, along with RoHS and REACH declarations for material responsibility. The AX50–AX80 family offers 3 NO main contacts and 1 NO + 1 NC auxiliary contact, enabling compact, scalable control schemes. This translates to easier wiring, predictable maintenance, and improved uptime in manufacturing environments.
Product Information
Extended Description
1SBL411074R2611 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 80 A | (440 V) 55 °C 70 A | (500 V) 55 °C 65 A | (690 V) 55 °C 46 A | (380 / 400 V) 55 °C 80 A | (220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW | (440 V) 40 kW | (500 V) 45 kW | (690 V) 40 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 105 V | 60 Hz 110 ... 127 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522408266
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AX50–AX80 block contactor uses a robust 3-pole main contact design with 1 NO auxiliary and 1 NC auxiliary contact, enabling compact motor control with flexible control wiring. Benefit: reduces panel footprint and simplifies wiring harnesses, lowering installation time and wiring costs for 3-phase motors up to 690 V AC in packaging lines or pumps. Application: ideal for medium-power conveyors, fans, and pump duty where space is at a premium and reliability matters. Feature → Compatibility → Installation advantages: Screw terminals, IP20 protection, and a wide rated voltage range (main circuit up to 690 V, auxiliary up to 690 V) support straightforward, code-compliant integration in control panels. Benefit: minimizes field wiring errors and enables quick retrofits with existing 50/60 Hz control voltages. Application: compatible with standard control circuits using 105 V at 50 Hz or 110–127 V at 60 Hz coils, easing procurement and stocking. Feature → Performance → Reliability: Conforms to IEC 60947-4-1 for contactor performance with 125 A Ith and high short-time withstand current, ensuring stable switching under transient faults. Benefit: improves motor protection and reduces nuisance trips, translating to less downtime. Application: critical for CNC machines, extrusion lines, and processing equipment where uptime directly drives throughput. Feature → Compliance → Documentation: Data sheet, CAD drawings, and manuals available (2D/3D CAD). Benefit: accelerates engineering approvals and enables accurate modeling in BIM/CDM workflows. Application: beneficial for design validation and supplier documentation packets. Feature → Certification → Global reach: The unit carries CE, UL/CSA, CCC, CQC, and CB certificates, with RoHS and REACH compliance. Benefit: supports global procurement strategies and regulatory compliance across customer footprints. Application: suitable for international manufacturing sites and multinational OEMs.
Get a Quick Quote for a ABB 1SBL411074R2611
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL411074R2611?
Enquire Now
FAQs
This ABB block contactor is a 3-pole device with 3 main NO contacts and 1 NO plus 1 NC auxiliary contact, designed for 690 V AC systems. It uses screw terminals, IP20 protection, and is compatible with 50 Hz coils at 105 V or 60 Hz coils at 110–127 V, simplifying wiring and panel layout.
AC-1 rated Ie is 105 A at 220/240 V, 125 A at 690 V (70 °C). AC-3 rated Ie ranges from 46–80 A depending on voltage (e.g., 80 A at 415/380/400 V, 65–70 A at higher voltages). P_e values correspond (up to 40–45 kW at typical industrial voltages) to support motor load calculations.
Yes. The unit is rated for main circuits up to 690 V AC with coil voltages suitable for 50 Hz and 60 Hz systems. It offers insulation up to 690 V and a high short-time withstand current, making it appropriate for 3-phase motor control in industrial applications.
The product carries CE conformity, UL/CSA approvals, CCC, CQC, CB certificates, CCC Declaration of Conformity, REACH and RoHS declarations, as well as WEEE B2B classifications. These support global compliance in multinational manufacturing environments.
With screw terminals, IP20 protection, and a compact block design, installation is faster and wiring errors are reduced. Compatible with standard 50/60 Hz control voltages, spare parts and auxiliaries are readily available, contributing to lower maintenance cost and improved uptime in high-demand lines.