ABB 1SBL411074R7500 Block Contactor - UL/CSA 105 A

Part Number: 1SBL411074R7500
Manufacturer
ABB
Part number
1SBL411074R7500

Quick Summary

ABB 1SBL411074R7500 block contactor controls 3-phase motors up to 690 V AC in industrial drives. Engineering teams often wrestle with reliable motor switching under load, long term enclosure integrity, and easy field maintenance. This device carries CE, UL/CSA, CCC, and CQC certifications, supporting global installations and safety compliance. Its block design, three main contacts, and screw terminals simplify panel assembly, while optional auxiliary contact blocks offer scalable control logic for alarms and interlocks. By combining compact dimensions with robust performance, it delivers predictable startup behavior and lowers total cost of ownership in OEM, maintenance, and retrofit projects. This makes it a practical choice for panel builders and system integrators seeking reliability and ease of procurement.

Product Information

Extended Description

1SBL411074R7500 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 80 A | (440 V) 55 °C 70 A | (500 V) 55 °C 65 A | (690 V) 55 °C 46 A | (380 / 400 V) 55 °C 80 A | (220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW | (440 V) 40 kW | (500 V) 45 kW | (690 V) 40 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 200 V | 60 Hz 200 ... 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522407757
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three main poles and a 690 V rated main circuit enable direct control of 3-phase motors, reducing wiring complexity and improving startup reliability. Business Impact: Faster commissioning and fewer field wiring errors translate to lower installation costs and improved plant uptime. Application: Ideal for conveyors, pumps, and fans in OEM equipment and end-user facilities. Feature: Coil operating voltage of 200 V at 50/60 Hz provides standard control compatibility across European and North American systems. Business Impact: Simplified integration with existing control cabinets and readily available spares; reduces inventory variety. Application: Common in plant automation and panel builders. Feature: Add-on auxiliary contact blocks (optional) for side mounting extendable control logic without replacing the base unit. Business Impact: Scalable signaling for interlocks, status feedback, and alarm circuits; improves fault detection. Application: Control panels and safety interlocks. Feature: IP20 rated coil terminals and screw connections support safe installation in standard enclosures. Business Impact: Easier mounting in fitted panels with dependable terminations; reduces commissioning time. Application: Typical machine hangs and control cabinets in harsh environments. Feature: Power loss of 7 W per pole (AC-1) and 2 W per pole (AC-3) delivers energy efficiency and cooler operation. Business Impact: Lower energy consumption and reduced cooling requirements, contributing to total cost of ownership reductions. Application: Continuous duty motor control scenarios. Feature: Compact footprint—82 mm width, 110 mm depth, 108 mm height, weight 1.05 kg—facilitates dense panel layouts. Business Impact: Higher packing density in control rooms and smaller enclosures; easier retrofits. Application: Retrofit projects and new machine builds. Feature: Certifications including CE, UL/CSA, CCC, and CQC streamline procurement and multi-region deployment. Business Impact: Simplified supplier qualification, faster approval cycles, and reduced compliance risk. Application: Global manufacturing environments and systems integrator projects.

Get a Quick Quote for a ABB 1SBL411074R7500

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL411074R7500? Enquire Now

FAQs

The ABB 1SBL411074R7500 is a three-pole block contactor designed to control 3-phase motors and power circuits up to 690 V AC. It supports mains up to 690 V and a rated current Ie of up to 125 A at 690 V, making it suitable for large fans, pumps, conveyors and other heavy-load applications.
This block contactor carries CE, UL/CSA, CCC, and CQC certifications. These approvals facilitate global procurement, ease compliance with regional electrical codes, and reduce qualification time in multinational or multi-site projects, while signaling adherence to safety and performance standards expected in industrial environments.
The device measures 82 mm in width, 110 mm in depth, and 108 mm in height, with a net weight of 1.05 kg. These compact dimensions support dense panel layouts and easier retrofits, enabling efficient use of enclosure space during installation or replacement.
The 1SBL411074R7500 is designed for typical AC-1 and AC-3 switching with a maximum switching frequency of 600 cycles per hour. It supports optional auxiliary contact blocks for signaling and interlocks, and is compatible with external thermal overload relays within AX50-80A configurations to enhance protection for motors with high inrush or thermal sensitivity.
Power loss is 7 W per pole for AC-1 operation and 2 W per pole for AC-3 operation, contributing to moderate energy use and cooler running in steady-state conditions. Maintenance benefits include robust mechanical design, standard screw terminals, and compatibility with common accessories, which simplify servicing and spare-part sourcing.