ABB 1SBL411074R8000 Block Contactor - CE UL Certified

Part Number: 1SBL411074R8000
Manufacturer
ABB
Part number
1SBL411074R8000

Quick Summary

ABB 1SBL411074R8000 Block Contactor is a three-pole AC motor controller designed for demanding 3-phase circuits up to 690 V. In many installations, engineers face inconsistent switching, alignment issues with auxiliary contacts, and difficult maintenance. This block contactor integrates a robust 3 main poles, AC-operated coil, and optional side-mounted auxiliary blocks to simplify upgrades. With CE, UL/CSA, and CB/CCC certifications, it meets global safety standards while RoHS and WEEE compliance support sustainable procurement. By combining predictable switching, efficient coil power, and scalable accessories, this device reduces downtime, improves energy efficiency, and lowers total cost of ownership in automation lines.

Product Information

Extended Description

1SBL411074R8000 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 80 A | (440 V) 55 °C 70 A | (500 V) 55 °C 65 A | (690 V) 55 °C 46 A | (380 / 400 V) 55 °C 80 A | (220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW | (440 V) 40 kW | (500 V) 45 kW | (690 V) 40 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522407801
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707366
The ABB 1SBL411074R8000 block contactor provides 3 NO main contacts with a main circuit rated up to 690 V, enabling straightforward control of 3-phase motors in demanding automation lines. This feature reduces wiring complexity and panel footprint while delivering reliable operation under high inrush conditions, so conveyors, pumps, and fans start smoothly with minimal downtime. The design supports optional add-on auxiliary contact blocks for side mounting, allowing seamless expansion of control circuits without replacing the base unit, which lowers spare parts inventory and speeds commissioning. Coil voltage is standardized to 220–230 V at 50 Hz or 230–240 V at 60 Hz, improving compatibility with common PLC outputs and control panels. With IP20 coil terminations and IP10 main terminations, installation and maintenance become more straightforward in typical switchgear environments.

Get a Quick Quote for a ABB 1SBL411074R8000

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL411074R8000? Enquire Now

FAQs

For proper installation, mount the unit in a suitable switchgear or control cabinet with the coil terminals protected and accessible. Use screw terminals and torque controls: 1 N·m for the control circuit and 4 N·m for the main circuit. Ensure IP20 protection on the coil side and IP10 on the main terminals, and verify ratings align with the system voltage and motor current.
The device provides 3 main NO contacts with a main circuit rated up to 690 V and can handle rated operational currents up to 125 A for AC-3 and 105–125 A for AC-1 depending on DC/AC lineup and ambient temperature. The coil is 220–230 V at 50 Hz or 230–240 V at 60 Hz, enabling standardization across most industrial PLC outputs.
Yes. The 3-pole design, 690 V insulation, and 125 A Ie rating for AC-3 support motor starting and running in conveyors, pumps, fans, and other driven loads. Its compact footprint, optional auxiliary contacts, and wide accessory ecosystem help tailor sequencing and interlocks for high-availability equipment.
The AX50–AX80 family carries CE and UL/CSA certifications, CB and CCC registrations, plus RoHS and REACH declarations. These approvals ease regulatory submissions, support cross-border sales, and ensure conformant safety and environmental performance for global manufacturing operations.
By featuring a robust 3-pole design, standardized coil voltage, optional auxiliary blocks, and modular accessories, maintenance is simplified and spare parts stocking minimized. The result is reduced downtime, lower total cost of ownership, and faster commissioning, delivering measurable ROI in automation projects with frequent motor switching.