ABB 1SBL411074R8011 Block Contactor - 690V UL/CE

Part Number: 1SBL411074R8011
Manufacturer
ABB
Part number
1SBL411074R8011

Quick Summary

ABB 1SBL411074R8011 Block Contactor is designed to switch three-phase motors up to 690 V in demanding industrial environments. Engineers often struggle with startup surges, limited panel space, and maintenance overhead when using older relays. This device carries CE, UL, and CCC certifications, aligning with global regulatory needs and reducing supplier risk. With a compact 82 mm width, a robust 125 A thermal current rating, and easy compatibility with add-on auxiliary blocks, it supports efficient motor control across regions while simplifying installation and future upgrades.

Product Information

Extended Description

1SBL411074R8011 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
AETAD009EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRABB008EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHSEC006EXPU
Country of Origin
India (IN)
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABB003EXPU
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
82 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.05 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 80 A | (440 V) 55 °C 70 A | (500 V) 55 °C 65 A | (690 V) 55 °C 46 A | (380 / 400 V) 55 °C 80 A | (220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW | (440 V) 40 kW | (500 V) 45 kW | (690 V) 40 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.16 kg
Package Level 1 EAN
3471522408808
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.6 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three-pole main contact arrangement (3 NO) with a single NO/NC auxiliary contact. Benefit: Ensures reliable motor control and expanded control logic within a compact footprint, enabling streamlined wiring and reduced panel complexity. Application: Suitable for IEC 60947-4-1 block contactor applications in conveyor, pump, and machine tool drives. Feature: Rated insulation voltage of 690 V and impulse withstand voltage of 6 kV. Benefit: Enhances insulation integrity and protection against surges, lowering failure risk in harsh industrial settings. Application: Global motor control tasks where peak voltages and transients may occur. Feature: Coil voltage compatibility for 50 Hz and 60 Hz systems (220–230 V / 230–240 V). Benefit: Flexible integration with standard control circuits, reducing commissioning time and wiring errors. Application: New installations and panel retrofits across regions with varying electrical standards. Feature: High short-time withstand current (Icw) and maximum breaking capacity (AC-1 and AC-3 ratings). Benefit: Handles motor inrush and switching events without nuisance tripping, reducing downtime and extending drive life. Application: Heavy duty motor starts in pumps, fans, and rollers with demanding duty cycles. Feature: Robust mechanical performance and moderate power loss (7 W AC-1 per pole; 2 W AC-3 per pole). Benefit: Lower heat generation, improved energy efficiency, and extended component life. Application: Continuous operation environments where heat management is critical. Feature: Compact dimensions (82 mm width, 110 mm depth, 108 mm height) and weight of 1.05 kg; screw terminals; IP20 coil terminals; IP10 main terminals. Benefit: Easy installation, secure connections, and reliable operation in control panels with restricted space. Application: Modern machine builds and retrofit projects with tight enclosure space. Feature: Comprehensive certification and compliance footprint (CE, UL, CCC). Benefit: Simplifies procurement and cross-border deployments while meeting diverse regulatory requirements. Application: Global rollouts across manufacturing networks and international suppliers.

Get a Quick Quote for a ABB 1SBL411074R8011

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL411074R8011? Enquire Now

FAQs

It is a 3-pole block contactor configured for 690 V main circuit operation with 3 NO main contacts and 1 NO/1 NC auxiliary, designed for AC-3 and AC-1 duty, making it suitable for typical 3-phase motor control applications up to 125 A with 50/60 Hz control voltages.
Dimensions are 82 mm wide, 110 mm deep, 108 mm high with a weight of 1.05 kg. It uses screw terminals, coil terminals are IP20 protected, main terminals IP10, and tightening torques of 1 N·m (control) and 4 N·m (main). Compatible with add-on auxiliary blocks for side mounting.
Rated operational current AC-3 up to 80–80 A depending on voltage and temperature, short-time withstand current up to 1000 A for 1 second, and a maximum breaking capacity of up to 1300 A at 440 V. These figures enable safe startup surges and durable operation in demanding loads.
The product carries CE, UL, and CCC certifications, with additional declarations for RoHS, REACH, and other compliance aspects, facilitating global procurement and cross-border deployments.
Warranty terms specify that a product under warranty must be returned. The device is built for robust thermal performance and low idle power loss, supporting longer service life and reduced maintenance intervals in standard industrial environments.