Block Contactor ABB 1SBL411074R8300 is designed to reliably switch and protect 3-phase motors and power circuits up to 690 V AC. In modern control panels, engineers often struggle with space, wiring complexity, and timely approvals, so a compact, easy-to-install solution helps. This device carries CE, UL, and CCC certifications and offers IP20 coil terminals with IP10 main terminals to meet common industrial standards. Designed for 48 V control circuits and AC-3 duty, it delivers predictable performance with low maintenance, supporting efficient automation projects and reduced total cost of ownership.
Product Information
Extended Description
1SBL411074R8300 ABB: AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 50~80A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
70 mm
Product Net Depth / Length
110 mm
Product Net Height
108 mm
Product Net Weight
1.01 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 105 A | (690 V) 40 °C 125 A | (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 80 A | (440 V) 55 °C 70 A | (500 V) 55 °C 65 A | (690 V) 55 °C 46 A | (380 / 400 V) 55 °C 80 A | (220 / 230 / 240 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe)
(415 V) 40 kW | (440 V) 40 kW | (500 V) 45 kW | (690 V) 40 kW | (380 / 400 V) 37 kW | (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-3) 600 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 7 W | at Rated Operating Conditions AC-3 per Pole 2 W
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 14 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 22 ms | Between Coil Energization and NO Contact Closing 8 ... 27 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Tightening Torque
Control Circuit 1 N·m | Main Circuit 4 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 105 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 25 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 15 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 35 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 78.2 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 68 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 50~80A CB certification
CCC Certificate
9AKK107492A7091
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
102 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Height
152 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
3471522407832
Package Level 2 Units
10 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
11.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3 main NO contacts in a 3-pole design. Business Impact: Handles motor loads with a high level of reliability, reducing part count and simplifying wiring. Application: Suitable for conveyor, pump, and fan motor control in harsh environments. Feature: Rated main and auxiliary circuit separation with IP20 coil terminals and IP10 main terminals. Business Impact: Safer terminal connection and easier panel routing, lowering installation risk and downtime. Application: Ideal for standard control cabinets where coil access is frequent. Feature: Control circuit voltage of 48 V at 50/60 Hz. Business Impact: Compatible with common PLC and automation logic, enabling seamless integration and faster commissioning. Application: Directly pairs with ABB and third-party control systems. Feature: Thermal current Ith of 125 A and AC-3 current ratings across voltages up to 690 V. Business Impact: Higher starting torque capability and greater motor protection margin, reducing nuisance trips. Application: Large AC motors in packaging, material handling, and water/pump systems. Feature: Power loss of 7 W per pole (AC-1) and 2 W per pole (AC-3). Business Impact: Lower heat generation and energy waste, contributing to cooler panels and longer component life. Application: Continuous duty drives and cycle-heavy applications. Feature: Optional add-on auxiliary contact blocks. Business Impact: Extends monitoring and interlock capabilities without replacing the base unit. Application: Safe sequencing and interlocking in automated lines. Feature: Comprehensive certifications (CE, UL, CCC, CQC) and compliance declarations. Business Impact: Facilitates regulatory approvals and supplier qualification processes, reducing time-to-operation. Application: Global deployment across construction, manufacturing, and process industries.
Get a Quick Quote for a ABB 1SBL411074R8300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL411074R8300?
Enquire Now
FAQs
This 3-pole block contactor features screw terminals and a compact footprint suitable for standard DIN-rail panel mounting. With 70 mm width, 110 mm depth, and 108 mm height, it fits common control cabinets and is compatible with 48 V control circuits and 690 V main circuits, enabling straightforward integration into most automation architectures.
For AC-3 duty at 690 V, the contactor provides up to 46 A Ie, with a maximum mechanical switching frequency of 3600 cycles per hour and a short-time withstand capability suitable for motor starting surges. This ensures reliable motor control for frequently started loads while maintaining protection margins.
Yes. The unit includes CE declarations and a UL certificate, along with CCC documentation, reflecting global compliance. It also carries RoHS/REACH declarations, supporting regulatory requirements for safe, responsible electrical equipment in industrial environments.
Yes. The AX 50–80 A family supports add-on auxiliary contact blocks for side-mounting and extended control/interlock capabilities. This allows enhanced monitoring and interlocking without replacing the base contactor, aligning with more complex automation schemes.
Product net width is 70 mm, depth 110 mm, and height 108 mm, with a net weight of 1.01 kg. These compact dimensions enable dense panel layouts and easier wiring, reducing panel size and increasing available space for other components or future expansion.