The ABB 1SBL911074R3601 Block Contactor is designed to control 3-phase motors and power circuits up to 690 V AC. This compact, 3-pole device helps reduce wiring complexity while delivering reliable switching in demanding automation environments. The unit ships with a built-in auxiliary NC contact and is coil-driven for straightforward control at 50 Hz (190 V) or 60 Hz (220 V). For engineers and procurement teams, the challenge is ensuring compatibility with existing AX contactor accessories and maintenance routines without sacrificing uptime. By combining robust protection with flexible mounting options and a strong certification profile, this contactor supports compliant, efficient motor control in factory floors and electrical rooms alike. In practice, it complements broad ABB AX-series compatibility and overall project cost savings.
Product Information
Extended Description
1SBL911074R3601 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A | (690 V) 40 °C 25 A | (690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A | (440 V) 55 °C 9 A | (500 V) 55 °C 9 A | (690 V) 55 °C 7 A | (380 / 400 V) 55 °C 12 A | (220 / 230 / 240 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V | 60 Hz 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7.5 hp | (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522394361
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The AX12-30-01-36 family design offers 3 main NO contacts and 1 built-in auxiliary NC contact, enabling compact motor control for 3-phase loads up to 690 V AC. This configuration minimizes panel footprint while maintaining reliable interlock and control signaling for start/stop sequences in conveyors, pumps, and fans. Application: ideal for machine building and OEM panels where space is at a premium and front-side or side-mounted accessory blocks are needed. Feature → Business Impact → Application: Coil voltage options 190 V at 50 Hz and 220 V at 60 Hz ensure compatibility with standard control circuits, reducing the need for intermediate voltage conversion and lowering wiring errors in control cabinets. Application: common in automation racks, PLC-synced control schemes, and remote motor starters. Feature → Business Impact → Application: 690 V rated insulation and 6 kV impulse withstand on auxiliary circuits provide robust insulation margins and improved surge resilience. Application: essential in high-energy environments subject to transients, such as metal forming or material handling lines. Feature → Business Impact → Application: 44 mm width, 74 mm depth, 74 mm height with IP20 protection simplifies installation and wiring within tight enclosures. Application: preferred for retrofit projects and new builds where space, protection class, and accessibility are critical. Feature → Business Impact → Application: Screw terminals and a 1 N·m tightening torque deliver secure, vibration-resistant connections with straightforward maintenance. Application: long-term reliability in workshops and production halls with frequent thermal cycling. Feature → Business Impact → Application: 3 main poles plus 1 NC auxiliary contact enable straightforward wiring of control circuits and interlocking without requiring additional modules. Application: supports standard motor control logic and safety interlocks in packaging lines and HVAC applications. Feature → Business Impact → Application: Extensive documentation and compatibility with add-on auxiliary blocks for front or side mounting reduce installation time and enable scalable control architectures. Application: valuable in expanding automation projects that must adapt to evolving control needs. Feature → Business Impact → Application: RoHS, REACH, and UL/CE declarations ensure regulatory compliance across global supply chains. Application: essential for international deployments and OEM-grade equipment that must meet multiple safety and environmental standards.
Get a Quick Quote for a ABB 1SBL911074R3601
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL911074R3601?
Enquire Now
FAQs
This model uses screw terminals with a compact 44 mm width, 74 mm depth and 74 mm height, designed for easy wiring in tight panels. It supports add-on auxiliary contact blocks for front or side mounting, enabling flexible installation in control cabinets and machine panels.
The contactor is controlled by a 190 V coil at 50 Hz or 220 V at 60 Hz. Main circuit rated up to 690 V, with 3 main NO contacts and 1 NC auxiliary contact. Operational currents vary by voltage, and the device meets relevant AC-3 and AC-1 ratings for motor starters in industrial environments.
Yes. It includes a CE Declaration of Conformity and UL certification, along with RoHS compliance. This combination supports regulatory approval across major markets and reduces compliance risk in global deployments.
Maximum mechanical switching frequency is 3600 cycles per hour, with maximum electrical switching up to 1200 cycles per hour for AC-3, and 900 cycles per hour for DC-13. This provides reliable cycling for typical industrial motor applications and helps plan maintenance and downtime more accurately.
The unit supports add-on auxiliary blocks and is compatible with front or side mounting accessories, reducing wiring effort and enabling scalable control architectures. Consider wire routing, IP20 protection on terminals, and tightening torque of 1 N·m for quick, robust installations in automation panels.