ABB 1SBL911074R3610 Contactor - UL/CE 690V

Part Number: 1SBL911074R3610
Manufacturer
ABB
Part number
1SBL911074R3610

Quick Summary

ABB 1SBL911074R3610 Contactor handles 3-phase motor control up to 690 V AC. Engineers often struggle with limited panel space, inconsistent coil voltages, and lengthy installation times, making reliable, compact solutions essential. CE and UL certifications, along with RoHS and REACH declarations, support regulatory compliance across markets. This AX-series compatible block contactor accepts add-on auxiliary blocks for front or side mounting, features compact dimensions and IP20 protection, and provides CAD files for rapid integration into electrical drawings, delivering tangible time and space savings for panel builders and system integrators.

Product Information

Extended Description

1SBL911074R3610 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A | (690 V) 40 °C 25 A | (690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A | (440 V) 55 °C 9 A | (500 V) 55 °C 9 A | (690 V) 55 °C 7 A | (380 / 400 V) 55 °C 12 A | (220 / 230 / 240 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V | 60 Hz 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7.5 hp | (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522393364
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3 main NO contacts and 1 NO auxiliary contact for consolidated control of 3-phase loads. Business Impact: Streamlined wiring and reduced component count, lowering installation time and potential wiring errors in control cabinets. Application: Ideal for motor control in conveyors, pumps, and fans where space is at a premium. Feature: Coil voltage 190 V at 50 Hz / 220 V at 60 Hz with AC operation. Business Impact: Compatible with common European power distribution without additional rectification equipment, reducing panel complexity. Application: Direct integration into systems powered by standard 190 V / 220 V control circuits. Feature: 690 V rated insulation and operational voltage with 50/60 Hz frequency. Business Impact: Safe, standards-compliant switching for high-voltage motor circuits, minimizing insulation coordination issues. Application: Heavy-duty industrial drives and power circuits up to 690 V. Feature: Power loss of 0.8 W per pole (AC-1) and 0.1 W per pole (AC-3). Business Impact: Lower standby and running heat, enabling higher packing density and reduced cooling needs. Application: Continuous-duty control in fabrications lines and processing equipment. Feature: Mechanical and electrical switching capabilities, with a maximum frequency of 3600 cycles/hour mechanically and 1200 cycles/hour electrically. Business Impact: Higher lifecycle performance and predictable uptime for automation sequences. Application: Frequent on/off control in process automation. Feature: IP20 protection and screw terminal connection with 1 N·m tightening torque. Business Impact: Robust, vibration-tolerant installations with secure wiring and easy field maintenance. Application: Panel assemblies, control cabinets, and machine-built controls. Feature: Add-on auxiliary contact blocks and CAD dimensional drawings for fast integration. Business Impact: Accelerates design, reduces engineering time, and ensures accurate 2D/3D models for downstream CAD workflows. Application: Systems engineering and retrofit projects that require precise documentation and quick deployment.

Get a Quick Quote for a ABB 1SBL911074R3610

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL911074R3610? Enquire Now

FAQs

Install the 3 main NO contacts and 1 NO auxiliary contact using screw terminals with a tightening torque of 1 N·m. Use the compact 44 mm width and 74 mm depth to optimize panel space, and consider add-on auxiliary blocks for front or side mounting to simplify wiring and future expansion.
The coil is rated 190 V at 50 Hz or 220 V at 60 Hz, and the coil is AC-operated. This makes it compatible with standard European control circuits without additional rectification equipment.
Yes. It is rated for up to 690 V AC. Rated Operational Current (Ie) AC-3 at 690 V is 7 A (55°C); at 380/400 V it is 12 A; at 415/440/500 V it ranges from 9 A to 12 A depending on voltage. For AC-1 applications at 690 V, Ie is 25 A (40°C) but reduces with temperature rise.
The contactor carries CE and UL certifications, along with RoHS and REACH declarations, plus related material compliance supporting safe and compliant global deployment.
Net dimensions are 44 mm W x 74 mm D x 74 mm H with a net weight of 0.326 kg. Packaging is 1 piece per box, with Level 2 packaging at 30 pieces per carton, and EAN 3471522393364 for logistics. Compatible CAD drawings are available for faster integration.