ABB 1SBL911074R8010 Block Contactor is a 3-pole AC switch for controlling 3-phase motors and power circuits up to 690 V. This design helps machine builders reduce panel complexity and wiring while delivering reliable switching performance. Many users struggle with space constraints and compatibility when upgrading control cabinets; this ABB contactor addresses those challenges with a compact footprint and standard 50/60 Hz coil options. It carries CE, UL and CCC declarations, with additional certifications such as CQC and RoHS compliance that support global installations. By combining efficient coil power, integrated auxiliary contact, and a robust 690 V insulation rating, this device supports faster commissioning, easier maintenance, and safer operation in industrial environments, boosting uptime and energy efficiency.
Product Information
Extended Description
1SBL911074R8010 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A | (690 V) 40 °C 25 A | (690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A | (440 V) 55 °C 9 A | (500 V) 55 °C 9 A | (690 V) 55 °C 7 A | (380 / 400 V) 55 °C 12 A | (220 / 230 / 240 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7.5 hp | (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522393807
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707314
Three main NO contacts and one built-in auxiliary NO contact provide a compact, all-in-one solution for switching three-phase motors and power circuits up to 690 V, reducing wiring complexity and panel footprint while improving control reliability. This design supports straightforward installation and scalable control architectures in conveyors, pumps, and fans. The compact form factor—44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg—saves valuable space in control panels and machine cabinets, enabling denser panel layouts and simpler maintenance. The AC-operated coil supports standard mains at 50 Hz (220–230 V) or 60 Hz (230–240 V), ensuring easy integration with existing electrical infrastructure and minimizing modification work during upgrades. Rated insulation voltage of 690 V and robust breaking capacity deliver predictable performance in demanding environments, while add-on auxiliary contact blocks offer flexible interlocking and signaling options. Operating power loss is low—0.8 W per pole in AC-1 and 0.1 W per pole in AC-3—driving energy efficiency in high-availability applications. The device is designed for quick commissioning with standard screw terminals, a 1 N·m tightening torque, and a straightforward mounting footprint, making spare parts and service alignment more efficient for maintenance teams. With IP20 protection on coils and terminations, and a tight integration with standard ETIM/UNSPSC classifications, it remains compatible with modern automation ecosystems and Industry 4.0-ready control panels. Industrial users benefit from a proven, globally certified contactor that supports reliable long-term operation, reduced downtime, and cost-effective scalability.
Get a Quick Quote for a ABB 1SBL911074R8010
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL911074R8010?
Enquire Now
FAQs
This 3-pole contactor uses screw terminals for the main, auxiliary, and control circuits, with a tightening torque of 1 N·m per terminal. It features IP20 protection and a compact 44 x 74 x 74 mm footprint, making it compatible with standard mounting rails and control panels. Optional add-on auxiliary contact blocks extend signaling and interlocking capabilities, supporting modular installation without rewriting cabinet layouts.
For AC-1 operation, Ie is 22 A at 220/240 V (55 °C) and 25 A at 690 V (40 °C). For AC-3, Ie ranges from 12 A at 415 V (55 °C) down to 7 A at 690 V (55 °C), with other voltage combinations provided in the datasheet. The maximum breaking capacity is specified at 250 A cos φ=0.45 for 440 V and 90 A cos φ=0.45 for 690 V, supporting reliable motor switching in medium-to-high power applications.
Yes. It carries CE and UL certifications, with CCC, CQC and RoHS declarations supporting global installations. This combination helps ensure compliant integration into European and North American building standards, as well as broader international automated systems.
Coil voltage is available for 50 Hz at 220–230 V and 60 Hz at 230–240 V. Matching the coil with your local supply frequency minimizes voltage conversion needs, reduces heat in the control circuit, and simplifies wiring in legacy panels. This compatibility enables faster commissioning and reduces risk during upgrades or expansions.
Low coil power loss—0.8 W per pole (AC-1) and 0.1 W per pole (AC-3)—reduces energy consumption across large installations. The device supports predictable, long-term operation with a mechanical switching life of up to 3600 cycles and AC-3 operation up to 1200 cycles, improving uptime. Its compact footprint and standardized dimensions ease replacement and spare-part availability, lowering maintenance costs and enabling faster return on investment (ROI) in automated lines.