ABB 1SBL911074R8310 Block Contactor - UL/CSA CE

Part Number: 1SBL911074R8310
Manufacturer
ABB
Part number
1SBL911074R8310

Quick Summary

Block Contactor ABB 1SBL911074R8310 controls three-phase motors up to 690 V AC. This compact, reliable device addresses common panel-wiring and start-up challenges faced by engineers in automation environments. It carries important certifications such as CE, UL/CSA, and RoHS, ensuring compliance across European and North American operations. With a 48 V control circuit and 50/60 Hz compatibility, it integrates smoothly into standard control architectures, reducing wiring complexity and enabling faster commissioning. The combination of a 3NO main and 1NO auxiliary contact supports flexible control schemes while delivering robust motor protection and long-term uptime for industrial equipment.

Product Information

Extended Description

1SBL911074R8310 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A | (690 V) 40 °C 25 A | (690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A | (440 V) 55 °C 9 A | (500 V) 55 °C 9 A | (690 V) 55 °C 7 A | (380 / 400 V) 55 °C 12 A | (220 / 230 / 240 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 V | 60 Hz 48 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7.5 hp | (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522393838
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The ABB 1SBL911074R8310 uses three main NO contacts plus one NO auxiliary contact, enabling straightforward three-phase motor switching with built-in monitoring options. This reduces wiring density and simplifies diagnostics in packaging lines, conveyors, and pumps. Application: Ideal for compact control panels where space is at a premium and reliable motor control is required. Feature → Business Impact → Application: Control circuit is AC operated with a 48 V coil at 50/60 Hz, aligning with common PLC and automation logic. Benefit: lowers control cabinet power demands and improves compatibility with standard automation gear. Application: Suitable for direct integration into machine tool and material handling systems. Feature → Business Impact → Application: Rated Operational Current AC-3 at 690 V delivers up to 7 A, with AC-1 capabilities up to 25 A at 690 V, enabling use in many motor-start scenarios. Benefit: supports high inrush loads while maintaining safe interrupting capacity. Application: Drives fans, pumps, and small conveyors in industrial settings. Feature → Business Impact → Application: Conventional thermal current (I_th) 26 A at 40 °C and short-time withstands ensure reliable performance in startup transients. Benefit: reduces nuisance trips and extends motor life. Application: Suitable for demanding manufacturing lines where startup surges are common. Feature → Business Impact → Application: Compact 44 mm width and 74 mm depth with IP20 protection and screw terminals enable easy installation and maintenance. Benefit: saves panel space and lowers Wiring time during installations. Application: Used in panel assemblies for machine control. Feature → Business Impact → Application: RoHS, REACH, TSCA and multiple certifications (UL/CSA, CE) provide compliance confidence across global supply chains. Benefit: simplifies procurement and end-user regulatory adherence. Application: Ideal for multi-region deployments and refurbishments across factories.

Get a Quick Quote for a ABB 1SBL911074R8310

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL911074R8310? Enquire Now

FAQs

This device uses screw terminals for all circuits, with a Product Net Width of 44 mm, Depth 74 mm, and Height 74 mm, enabling straightforward wiring in compact control panels and easy field maintenance.
For AC-3 operation at 690 V, Ie is 7 A, while AC-1 permits up to 25 A at 690 V. At lower voltages (e.g., 415 V), the AC-3 rating drops accordingly; these ratings support starting and running loads typical of small to medium three-phase motors.
Yes. The product carries CE and UL/CSA certifications and is RoHS compliant, with additional declarations for REACH and related standards to support regulatory compliance in European and North American facilities.
The contactor uses a 48 V coil with a control circuit frequency of 50/60 Hz, aligning with standard PLC or automation system outputs and simplifying integration with existing control panels.
Best suited for motors up to 690 V AC in conveyors, pumps, machine tools, and packaging lines, especially where space is tight and a built-in auxiliary contact enhances monitoring and interlocking in automation sequences.