ABB 1SBL911074R8410 Block Contactor - CE/UL Certified
Part Number: 1SBL911074R8410
Quick Summary
Block Contactor ABB 1SBL911074R8410 controls 3-phase motors and power circuits up to 690 V AC, ideal for industrial automation. This solution addresses the common challenge of reliable motor switching under varied duty cycles and load conditions by combining a robust 3 main NO contacts with a built-in auxiliary NO contact for feedback and control. The device carries CE, UL, and CCC certifications, along with RoHS and REACH declarations, ensuring global compliance for manufacturing environments. Its compact 44 mm width and screw-terminal connections support efficient panel layouts, while predictable thermal performance reduces downtime. For design engineers and procurement teams, this translates to easier sourcing, scalable installations, and lower total cost of ownership in motor control applications.
Product Information
Extended Description
1SBL911074R8410 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A | (690 V) 40 °C 25 A | (690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A | (440 V) 55 °C 9 A | (500 V) 55 °C 9 A | (690 V) 55 °C 7 A | (380 / 400 V) 55 °C 12 A | (220 / 230 / 240 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7.5 hp | (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522393845
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707318
Feature → Business Impact → Application. The Block Contactor configuration provides 3 main normally open (NO) contacts plus 1 auxiliary NO contact, enabling straightforward motor control with feedback signals for PLCs and safety interlocks, reducing wiring complexity and improving control reliability in conveyors and pumps. This translates to shorter installation times and lower commissioning risk in new machines. Feature → Business Impact → Application. Control circuit voltage of 110 V at 50 Hz or 110–120 V at 60 Hz simplifies integration with standard control gear and existing automation cabinets, delivering seamless compatibility with common PLCs and relays, which minimizes additional control hardware and lowers lifecycle costs. Feature → Business Impact → Application. Rated operational currents up to 25 A at 690 V main circuit and 18 A at 690 V in AC-3 mode offer robust motor starting and running performance, enabling operations on mid-size industrial motors with predictable performance and reduced nuisance trips in packaging lines and material handling. Feature → Business Impact → Application. Insulation voltage rated to 690 V and a maximum switching frequency suitable for AC-1, AC-3, and DC-13 drive profiles provide flexibility across machine tools and processing lines, supporting upgrades without changing the control architecture. Feature → Business Impact → Application. Compact dimensions (44 mm width, 74 mm depth and height) and a weight of ~0.326 kg make it easy to integrate into compact control panels, reducing cabinet footprint and material costs while maintaining solid mounting and wiring integrity. Feature → Business Impact → Application. IP20 protection for main and coil terminals protects against dust ingress in standard factory environments, improving reliability in enclosed control panels and easier maintenance in service environments. Feature → Business Impact → Application. Compliance with RoHS, REACH, TSCA, and multiple regional certifications ensures regulatory alignment across global supply chains, reducing compliance overhead and facilitating cross-border procurement. Feature → Business Impact → Application. UL/CSA and CE declarations, along with CCC and CQC certifications, provide confidence in safety and performance, supporting product approvals for international markets and enabling faster time-to-value in project bids.
Get a Quick Quote for a ABB 1SBL911074R8410
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL911074R8410?
Enquire Now
FAQs
This 3-pole block contactor is designed for 3‑phase motors up to 690 V AC with main contacts NO and a built‑in auxiliary NO contact. It uses screw terminals and a compact 44 mm width, simplifying panel layouts and enabling straightforward wiring with standard control circuits at 110 V (50 Hz) or 110–120 V (60 Hz). Ensure the mounting space accommodates 74 mm depth and use appropriate DIN rail or panel mounting as specified by ABB’s AX series accessories.
The device provides rated operational currents up to 25 A at 690 V for the main circuit and 7–12 A in AC-3 depending on voltage, with a control coil at 110 V (50 Hz) or 110–120 V (60 Hz). It supports conventional control and switching performance suitable for starting and running mid‑size motors, with tight insulation voltage of 690 V and a maximum switching frequency appropriate for industrial applications.
Yes, it is designed for indoor control cabinets with IP20 protection on main and coil terminals, and it complies with RoHS, REACH, and TSCA standards. The device is built for reliable operation in typical factory ambient conditions, with a wide operating temperature range and robust mechanical life, reducing the risk of unplanned downtime in packaging, material handling, and machine tools.
The product carries CE, UL, CCC, and CQC certifications, along with RoHS and REACH declarations. These certifications confirm compliance with European, North American, and Chinese safety and environmental standards, facilitating global procurement, reducing compliance risk in multinational projects, and supporting regulatory readiness for machinery approvals.
The device’s compact footprint, reliable 3‑pole switching, and built‑in auxiliary contact reduce wiring complexity and panel space, lowering installation costs. Its robust construction and favorable operating currents minimize nuisance trips, improving motor uptime. Regular maintenance focuses on securing screw terminals and inspecting coil connections; routine checks help sustain performance across service intervals and extend the controller’s lifespan.