ABB 1SBL911074R8610 Block Contactor - 690V IEC 60947-4-1
Part Number: 1SBL911074R8610
Quick Summary
ABB 1SBL911074R8610 Block Contactor controls three-phase motors up to 690 V, enabling reliable, compact motor switching in industrial power circuits. Engineers often wrestle with space constraints, complex control architectures, and limited accessory options; this device addresses those challenges with a compact footprint and add-on auxiliary contact blocks for front or side mounting. The unit complies with critical safety and performance standards, including CE, UL and RoHS declarations, supporting global installations. For procurement teams, the combination of standardization, accessible CAD data, and a wide accessory ecosystem translates to reduced engineering time, lower spares holdings, and faster project delivery. In short, it blends robust performance with installation ease for quality electrical protection and circuit control in automation projects.
Product Information
Extended Description
1SBL911074R8610 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 22 A | (690 V) 40 °C 25 A | (690 V) 70 °C 18 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 12 A | (440 V) 55 °C 9 A | (500 V) 55 °C 9 A | (690 V) 55 °C 7 A | (380 / 400 V) 55 °C 12 A | (220 / 230 / 240 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 5.5 kW | (440 V) 4 kW | (500 V) 5.5 kW | (690 V) 5.5 kW | (380 / 400 V) 5.5 kW | (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 400 ... 415 V | 60 Hz 415 ... 440 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 0.8 W | at Rated Operating Conditions AC-3 per Pole 0.1 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 25 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 3/4 hp | (200 ... 208 V AC) Three Phase 3 hp | (220 ... 240 V AC) Three Phase 3 hp | (240 V AC) Single Phase 2 hp | (440 ... 480 V AC) Three Phase 7.5 hp | (550 ... 600 V AC) Three Phase 10 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 13.8 A | (200 ... 208 V AC) Three Phase 11 A | (220 ... 240 V AC) Three Phase 9.6 A | (240 V AC) Single Phase 12 A | (440 ... 480 V AC) Three Phase 11 A | (550 ... 600 V AC) Three Phase 11 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522393869
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3-pole block contactor design delivers clean control of 3-phase motors, reducing wiring complexity and panel space while improving reliability in motor circuits. This translates to lower enclosure footprint and faster commissioning on conveyors, pumps, and fans. Feature → Application: The built-in auxiliary NO contact and compatibility with add-on auxiliary contact blocks enable scalable control logic and future expansion without replacing the base device, supporting modular automation architectures in process lines. Feature → Benefit: Rated control circuit voltage of 400…415 V at 50 Hz and 415…440 V at 60 Hz aligns with global electrical grids, simplifying international projects and spare-part planning. Feature → Benefit: Ith of 26 A (Θ = 40 °C), with Ie and Ic values across voltage ranges, ensures the device handles motor starting surges while meeting IEC 60947-4-1 and IEC 60947-5-1 requirements. Feature → Benefit: Low coil power loss (0.8 W AC-1 per pole; 0.1 W AC-3 per pole) reduces energy consumption and heat in enclosures, improving reliability and reducing cooling costs. Feature → Application: The device’s IP20 protection and screw terminals support rugged indoor installations, easy wiring, and straightforward maintenance in factories, warehouses, and water-treatment facilities. Feature → Benefit: Compact dimensions (44 mm width, 74 mm depth, 74 mm height) fit tight control panels, enabling denser layouts and simplified retrofits in existing lines. Feature → Application: Mechanical and electrical life characteristics (3600 cycles mechanical; up to 1200 cycles/hour AC-3) support demanding duty cycles in packaging lines and material-handling equipment. Feature → Benefit: Industry-standard certifications (CE, UL, CCC, CQC, RoHS/REACH) reduce compliance risk and streamline supplier audits across global sites, providing a clear path for regulated industries.
Get a Quick Quote for a ABB 1SBL911074R8610
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL911074R8610?
Enquire Now
FAQs
The unit uses screw terminals for all connections and supports add-on auxiliary contact blocks for front or side mounting, enabling flexible wiring, easy field upgrades, and scalable control options in compact switchgear.
Key ratings include Ie up to 25 A at 690 V for AC-3, 12 A at 415 V for AC-3, and 22 A at 240 V for AC-1. It supports a maximum mechanical switching frequency of 3600 cycles/hour and AC-3 operation up to 1200 cycles/hour, suitable for motor control.
Yes. It offers IP20 protection, a compact 44x74x74 mm footprint, and a wide ambient range (-25 to 55 °C with thermal relay). This makes it suitable for indoor automation environments such as conveyors and pumping stations when properly mounted.
The contactor is CE and UL certified and also supports CCC and CQC declarations, with RoHS/REACH compliance. These certifications reduce regulatory risk, simplify supplier audits, and enable worldwide deployment in regulated industries.
Low coil power loss reduces heat and energy consumption, extending component life and reducing cooling requirements. Its robust build, standardized accessories, and modular auxiliary options minimize spare parts needs and shorten downtime during maintenance or upgrades.