Block Contactor ABB 1SBL921074R3601 is a 3-pole device designed to control 3-phase motors and power circuits up to 690 V AC. In control panels and automation installations, engineers often battle crowded layouts and complex wiring; this compact unit offers a 44 mm net width and front or side-mount accessory options to simplify assembly. The product carries CE and UL certifications and supports additional compliance such as CB, CCC, and CQC declarations, with RoHS and REACH conformity for sustainable procurement. With 3 main normally open contacts and 1 built-in NC auxiliary contact, it delivers reliable switching in a small footprint. This enables faster panel builds, easier maintenance, and lower total cost of ownership through standardized components and CAD-ready drawings.

Product Information

Extended Description

1SBL921074R3601 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 25 A | (690 V) 40 °C 27 A | (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 18 A | (440 V) 55 °C 12 A | (500 V) 55 °C 12 A | (690 V) 55 °C 9 A | (380 / 400 V) 55 °C 18 A | (220 / 230 / 240 V) 55 °C 18 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V | 60 Hz 220 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1 hp | (200 ... 208 V AC) Three Phase 5 hp | (220 ... 240 V AC) Three Phase 5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 10 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 16 A | (200 ... 208 V AC) Three Phase 17.5 A | (220 ... 240 V AC) Three Phase 15.2 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 14 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522396365
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The ABB 1SBL921074R3601 provides three main normally open contacts plus one built-in NC auxiliary contact, enabling reliable motor control for compact automation panels and machine controls. Benefit: reduces wiring complexity and panel height while maintaining robust feedback for automation sequences. Application: suitable for 3-phase motors and power circuits up to 690 V AC in diverse industrial settings. Feature → Coil voltage options of 190 V at 50 Hz or 220 V at 60 Hz, allowing seamless integration with existing control circuits and minimizing rework during retrofits. Benefit: flexible sourcing and faster commissioning across legacy and modern control systems. Application: installations with mixed voltage control loops and retrofitting projects. Feature → Rated operational currents and short-time withstand capabilities across multiple voltages (AC-1, AC-3, DC-13), delivering predictable performance under varying loads. Benefit: lower risk of nuisance trips, improved machine uptime, and easier compliance with safety standards. Application: motor starters, conveyors, pumps, and automation panels. Feature → Mechanical and electrical switching frequencies (AC-1, AC-3, DC-13) with a maximum mechanical rate of 3600 cycles/hour and electrical rates up to 1200 cycles/hour, plus IP20 protection and screw-terminal wiring. Benefit: supports high-frequency operation and reliable live switching in open plant environments. Application: high-cycle industries such as material handling and packaging. Feature → Compact dimensions (44 mm width, 74 mm depth and height) with lightweight construction (0.326 kg) and mounting compatibility. Benefit: saves panel space, reduces installation time, and lowers shipping and handling costs. Application: factory automation cabinets, machine enclosures, and control desks. Feature → Add-on auxiliary contact blocks and broad accessory compatibility for front or side mounting. Benefit: scalable I/O and easier integration into growing automation architectures. Application: future-proofing installations and modular control panel design. Feature → Wide compliance footprint including CE, UL, CB, CCC, and RoHS/REACH declarations. Benefit: ensures regulatory alignment for global installations and simplifies procurement across regions. Application: multinational projects and supplier qualification programs.

Get a Quick Quote for a ABB 1SBL921074R3601

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL921074R3601? Enquire Now

FAQs

When wiring the ABB 1SBL921074R3601, use the screw terminals and tighten to 1 N·m per circuit as specified. The device features three main normally open contacts and one built-in NC auxiliary contact and supports add-on auxiliary blocks for front or side mounting. Ensure the control coil is supplied with 190 V at 50 Hz or 220 V at 60 Hz, and verify IP20 protection in the control cabinet environment.
Key ratings include rated operational current AC-3 up to 18 A at 415 V, 12 A at 440–500 V, and 9 A at 690 V. The device also accommodates AC-1 and DC-13 loads with currents specified by voltage and temperature; rated insulation voltage is 690 V. The coil voltage is 190 V at 50 Hz or 220 V at 60 Hz, and switching frequencies reach up to 1200 cycles per hour (AC-3).
Yes, it supports high-cycle operation with a maximum electrical switching frequency of 1200 cycles/hour (AC-3) and a maximum mechanical switching frequency of 3600 cycles/hour. This combination makes it suitable for frequent motor starts and stops in automated lines, provided the load and ambient conditions stay within the specified ratings.
This block contactor carries CE and UL certifications and is complemented by CB, CCC, and CQC declarations. It also aligns with RoHS and REACH requirements, and there are DoC statements available for CE conformity. These certifications support regulatory compliance in global automotive, industrial, and electrical panels.
The 44 mm wide footprint, 74 mm depth and height, and 0.326 kg weight optimize panel space and reduce installation time. Built-in auxiliary contact and add-on blocks simplify wiring and future expansion, while CAD-ready drawings facilitate design and maintenance planning, contributing to lower total cost of ownership and faster project delivery.