ABB 1SBL921074R8110 Block Contactor - UL/CE Certified
Part Number: 1SBL921074R8110
Quick Summary
Block Contactor ABB 1SBL921074R8110 switches 3‑phase motors in industrial power circuits. This device helps engineers simplify motor control while reducing panel footprint. Maintenance teams often face coil chatter, contact wear, and unexpected downtime from undersized or poorly configured relays. The AX-type line features CE and UL/CSA approvals and RoHS compliance, with IP20 protection for safe control terminals and 690 V insulation capability for demanding mains. By combining a 24 V control coil with a compact 44 mm width and 74 mm depth profile, the solution delivers reliable operation in limited spaces. This makes it well suited for automation projects where safety, compliance, and long-term reliability matter to total cost of ownership.
Product Information
Extended Description
1SBL921074R8110 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 25 A | (690 V) 40 °C 27 A | (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 18 A | (440 V) 55 °C 12 A | (500 V) 55 °C 12 A | (690 V) 55 °C 9 A | (380 / 400 V) 55 °C 18 A | (220 / 230 / 240 V) 55 °C 18 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 V | 60 Hz 24 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1 hp | (200 ... 208 V AC) Three Phase 5 hp | (220 ... 240 V AC) Three Phase 5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 10 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 16 A | (200 ... 208 V AC) Three Phase 17.5 A | (220 ... 240 V AC) Three Phase 15.2 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 14 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522395818
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707327
Feature → Business Impact → Application: The block contactor design provides three main poles plus one NO auxiliary contact, delivering a clean, consolidated motor control path that reduces wiring complexity and component count in and around control panels. This translates to shorter wiring harnesses, easier diagnostic testing, and lower assembly time during machine integration for conveyors, pumps, and processing lines. Feature → Business Impact → Application: 24 V control voltage with 50/60 Hz operation aligns with standard automation controllers, enabling straightforward interoperability with PLCs and HMIs in mid and high-power applications. This reduces control-circuit complexity and accelerates commissioning for machine tools, packaging equipment, and material handling systems. Feature → Business Impact → Application: 690 V rated main and auxiliary circuits with IP20 protection ensure robust performance in challenging industrial environments, while the compact 44×74×74 mm footprint fits tight control panels. This supports upgrade projects and retrofit scopes where space is at a premium and compliance with CE/UL is mandatory. Feature → Business Impact → Application: Auxiliary contact blocks and wide accessory options support front or side mounting, enabling flexible panel layouts and scalable control logic for multi-motor starters and centralized power distribution. Feature → Business Impact → Application: Low coil power loss (1 W per pole in AC-1) improves overall energy efficiency and reduces heat in electrical cabinets, contributing to longer component life and lower cooling costs in high-density automation installations. Feature → Business Impact → Application: 3P NO main configuration with a single NO auxiliary contact simplifies sequencing, enabling reliable motor start/stop operations in heavy-duty processes such as extrusion, grinding, and milling lines. Feature → Business Impact → Application: Compliance and documentation (CE, UL, RoHS) reduce procurement risk and accelerate audit readiness for manufacturing environments with strict supplier requirements and regulatory obligations.
Get a Quick Quote for a ABB 1SBL921074R8110
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL921074R8110?
Enquire Now
FAQs
This device features three main poles and one NO auxiliary contact with screw terminals and a compact 44 mm width. Plan for a 1 N·m tightening torque per circuit and ensure suitable clearance for front or side-mounted add-on auxiliary blocks. Verify control wiring at 24 V AC and maintain IP20 protection for safe cabinet integration.
Rated Operational Current for AC-3 varies by voltage, up to 18 A at certain mains, with a 690 V insulation voltage. Coil voltage is 24 V at 50/60 Hz. The contactor supports high-frequency switching and offers a maximum short-time withstand current suitable for starting and stopping heavy motors without excessive wear.
Yes. It complies with IP20 protection for terminals and offers ambient temperature ranges from -40 to 70 °C in installation proximity. It is designed for 3000 m altitude without derating and is supported by RoHS, REACH, and multiple global conformity declarations, making it appropriate for factory automation and process equipment.
The model carries CE and UL certificates, CCC/CQC declarations, and RoHS/REACH compliance. A CE Declaration of Conformity and UL Certificate cover electrical safety and performance, while RoHS confirms restricted substance compliance, supporting audit and supplier qualification for regulated industries.
Benefits include reduced panel space due to a compact footprint, lower wiring time with integrated 3P plus auxiliary contact, and lower energy losses (1 W per pole in AC-1). The combination improves reliability, minimizes downtime, and lowers cooling requirements, delivering faster project deployment and favorable total cost of ownership for motor-driven lines.