ABB 1SBL921074R8410 Block Contactor - 690V IP20
Part Number: 1SBL921074R8410
Quick Summary
Block Contactor 1SBL921074R8410 controls 3‑phase motors in industrial power circuits. This ABB device delivers reliable motor control with a built‑in auxiliary contact, simplifying interlock and feedback wiring. Engineers often face challenges with compatible coil voltages, mounting options, and accessory availability across sites; this model offers a 110 V control circuit and a compact 44 mm width footprint to ease installation. It supports control signals at 50/60 Hz and main circuits up to 690 V, making it versatile in mixed‑voltage environments. Certifications such as CE, UL/CSA approvals, and RoHS compliance reinforce safety and regulatory alignment, while the robust IP20 protection provides dependable performance in free‑air installations. In practice, this translates to reduced wiring complexity, faster sourcing, and lower total cost of ownership for motor control solutions.
Product Information
Extended Description
1SBL921074R8410 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 25 A | (690 V) 40 °C 27 A | (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 18 A | (440 V) 55 °C 12 A | (500 V) 55 °C 12 A | (690 V) 55 °C 9 A | (380 / 400 V) 55 °C 18 A | (220 / 230 / 240 V) 55 °C 18 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1 hp | (200 ... 208 V AC) Three Phase 5 hp | (220 ... 240 V AC) Three Phase 5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 10 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 16 A | (200 ... 208 V AC) Three Phase 17.5 A | (220 ... 240 V AC) Three Phase 15.2 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 14 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522395849
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707328
Feature: Three main normally open contacts (NO) with one built‑in auxiliary NO contact. Benefit: Simplifies wiring for motor control and feedback without needing extra contact blocks, reducing panel space and assembly time. Application: 3‑phase motor starters in conveyors and pumps with compact footprint. Feature: 110 V control coil operating at 50/60 Hz. Benefit: Compatible with common control architectures and remote control schemes, lowering integration risk. Application: Centralized control cabinets and intelligent motor control centers. Feature: Main circuit rated up to 690 V and auxiliary circuit up to 690 V. Benefit: Wider motor and load compatibility, enabling one part to cover diverse line voltages and machine architectures. Application: Heavy machinery across packaging, material handling, and machine tooling. Feature: IP20 protection with screw terminals and 1 N·m tightening torque. Benefit: Easy installation with secure, vibration‑tolerant connections, ideal for rugged industrial environments. Application: Mounting in control panels with reliable terminal integrity. Feature: Compact dimensions (44 mm width, 74 mm depth, 74 mm height) and weight of 0.326 kg. Benefit: Minimal panel space and lightweight handling during installation or retrofits. Application: Retrofit projects and space‑constrained equipment rooms. Feature: Block‑style design with add‑on auxiliary blocks for front or side mounting. Benefit: Flexible configuration to match control logic and space constraints. Application: Customizable control layouts in OEM machinery. Feature: Certifications and compliance including CE, UL/CSA, RoHS. Benefit: Reduces regulatory risk and accelerates time‑to‑market with proven product conformance. Application: Global deployments across EU and North America where standards matter. These features collectively support measurable outcomes such as improved wiring efficiency, accelerated commissioning, and assured regulatory compliance in industrial motor control environments.
Get a Quick Quote for a ABB 1SBL921074R8410
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL921074R8410?
Enquire Now
FAQs
Install the 3‑pole device in a compatible enclosure, connect the three main NO contacts and the one auxiliary contact to the control circuit, and terminate the coil at 110 V with 50/60 Hz. Tighten all terminals to 1 N·m and ensure IP20 protection is maintained. Use proper front or side mounting accessories as needed for your panel layout.
Main contacts are 3 NO with a rated operational current up to 27 A at 690 V (AC‑3 depending on voltage and temperature). The auxiliary circuit is rated up to 690 V, with a 110 V coil for control at 50/60 Hz. Insulation voltage is 690 V, and the device supports typical AC‑1 and AC‑3 motor control profiles.
Yes. The contactor features a 110 V control circuit designed for 50 Hz or 60 Hz operations, enabling seamless integration with common control voltages in mixed‑voltage installations.
The product carries CE conformity and UL/CSA approvals, along with RoHS compliance and WEEE considerations. These certifications support regulatory alignment for European and North American deployments.
Consider an IP20 protection rating for free‑air panel mounting, ambient temperatures from −25 to 55 °C near the device, and up to 3000 m altitude without derating. The unit is 44 mm wide, 74 mm deep, and 74 mm high, weighing 0.326 kg, with screw terminals and a 1 N·m tightening torque per circuit for reliable connections.