ABB 1SBL921074R8801 Block Contactor - CE/UL Certification

Part Number: 1SBL921074R8801
Manufacturer
ABB
Part number
1SBL921074R8801

Quick Summary

ABB 1SBL921074R8801 Block Contactor is a 3-pole, AC-operated device for controlling 3-phase motors. For panel builders, space constraints and heat buildup are ongoing challenges; this unit addresses them with a compact 44 mm width and a lightweight 0.326 kg. CE, UL and CCC certifications accompany IP20 protection, supporting safe, compliant operation across global plants. Its coil voltage options and modular design enable easy integration with standard control panels, reducing wiring complexity and downtime while delivering reliable switching in demanding environments.

Product Information

Extended Description

1SBL921074R8801 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 25 A | (690 V) 40 °C 27 A | (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 18 A | (440 V) 55 °C 12 A | (500 V) 55 °C 12 A | (690 V) 55 °C 9 A | (380 / 400 V) 55 °C 18 A | (220 / 230 / 240 V) 55 °C 18 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1 hp | (200 ... 208 V AC) Three Phase 5 hp | (220 ... 240 V AC) Three Phase 5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 10 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 16 A | (200 ... 208 V AC) Three Phase 17.5 A | (220 ... 240 V AC) Three Phase 15.2 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 14 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522396884
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The 3 main NO contacts with 1 NC auxiliary contact enable robust motor control for 3-phase loads up to 690 V AC, while maximizing circuit protection and fault containment in machine lines. This translates to improved line safety and reduced risk of uncontrolled starts in conveyors and presses. Application: Suitable for motor control in manufacturing lines, packaging, and material handling where predictable switching is essential. Feature → Efficiency → Installation: Coil options of 230–240 V at 50 Hz or 240–260 V at 60 Hz provide flexible integration with standard mains, helping minimize wiring changes during upgrades. Application: Ideal for new builds and retrofit projects where a compact footprint saves panel real estate. Feature → Durability → Lifecycle: Power loss is 1 W per pole (AC-1) and 0.2 W per pole (AC-3), reducing heat generation and cooling costs in control cabinets. Application: Supports long-term operation in Euro-US industrial environments. Feature → Compatibility → Serviceability: Dimensions 44 mm width, 74 mm depth, 74 mm height, weight 0.326 kg, with screw terminals and 1 N·m tightening torque for all circuits. Application: Simplifies mounting, maintenance, and field servicing. Feature → Compliance → Market Reach: IP20 protection and wide certification coverage (CE, UL, CCC) enable safe operation across diverse markets and strict regulatory landscapes. Application: Ensures alignment with global procurement standards and reduces compliance risk.

Get a Quick Quote for a ABB 1SBL921074R8801

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL921074R8801? Enquire Now

FAQs

For reliable performance, ensure a 44 mm wide panel space with screw terminals and 1 N·m tightening torque on all circuits. Verify the coil voltage matches 230–240 V at 50 Hz or 240–260 V at 60 Hz, and maintain IP20 protection through proper enclosure. Allow ambient temperatures within -25 to 55 °C with thermal O/L if used.
Rated operational current AC-3 varies with voltage: up to 18 A at 415–440 V and down to 9 A at 690 V, with short-time withstand currents up to 145 A for 10 s and 300 A for 0.1 s. The device supports 50/60 Hz control, with 690 V insulation voltage and 6 kV impulse withstand in auxiliary circuits.
Yes. The 1SBL921074R8801 is designed for 3-phase motor control with 3 NO main contacts and 1 NC auxiliary contact, rated for up to 690 V and 27–28 A depending on voltage and ambient temperature. Its compact form factor and accessory compatibility make it suitable for compact machine controls and conveyors.
The device carries CE, UL, and CCC certifications, ensuring compliance with European, North American, and Chinese safety standards. RoHS, CB, and CCC declarations further support global procurement, while WEEE compliance indicates proper end-of-life handling. These certifications reduce regulatory risk and facilitate cross-border sourcing.
The contactor uses low power loss: 1 W per pole in AC-1 operation and 0.2 W per pole in AC-3, reducing heat and cooling requirements. Its mechanical switching frequency reaches 3600 cycles per hour, with durable 1 N·m torque joints and screw terminals for easy servicing. Overall, this supports higher uptime and lower energy costs over the asset’s life.