ABB 1SBL921074R8810 Block Contactor - 690V 27A UL/CE

Part Number: 1SBL921074R8810
Manufacturer
ABB
Part number
1SBL921074R8810

Quick Summary

ABB AX block contactor is a robust solution for controlling 3-phase motors up to 690 V AC in industrial panels. In tight panel layouts, complex wiring and integrating auxiliary contacts can slow projects; this device offers a compact, integrated solution with a built-in NO auxiliary contact for streamlined control. It carries CE, UL, and RoHS compliance, plus IP20 protection in terminations, coil, and main terminals, ensuring safe installation and reliable operation in diverse environments. Leveraging standard coil voltages of 230–240 V at 50 Hz (or 240–260 V at 60 Hz), this cont actor supports scalable motor control and easy maintenance, aligning with broader industrial automation and electrical protection needs.

Product Information

Extended Description

1SBL921074R8810 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
0
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 25 A | (690 V) 40 °C 27 A | (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 18 A | (440 V) 55 °C 12 A | (500 V) 55 °C 12 A | (690 V) 55 °C 9 A | (380 / 400 V) 55 °C 18 A | (220 / 230 / 240 V) 55 °C 18 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 9 kW | (440 V) 5.5 kW | (500 V) 7.5 kW | (690 V) 7.5 kW | (380 / 400 V) 7.5 kW | (220 / 230 / 240 V) 4 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 230 ... 240 V | 60 Hz 240 ... 260 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W | at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1 hp | (200 ... 208 V AC) Three Phase 5 hp | (220 ... 240 V AC) Three Phase 5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 10 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 9 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 16 A | (200 ... 208 V AC) Three Phase 17.5 A | (220 ... 240 V AC) Three Phase 15.2 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 14 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522395887
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Three main NO poles plus one auxiliary NO contact simplify motor control wiring and reduce panel space, enabling faster assembly and easier future expansion in machine tool and conveyor applications. Application: Used for 3-phase motor start/stop circuits in manufacturing lines. Feature → Business Impact → Application: AC-operated control circuit and standard coil voltages (230–240 V 50 Hz / 240–260 V 60 Hz) offer plug‑and‑play integration with common PLCs and control relays, reducing integration time and risk. Application: Servo and drive panels where quick coil energization is critical. Feature → Business Impact → Application: Rated operational currents accommodate AC‑1 and AC‑3 duty across voltages up to 690 V (Ie up to 27 A, 18 A for AC‑3), delivering dependable motor starting and breaking capacity. Application: Pumps, fans, and fans-in-series in industrial equipment. Feature → Business Impact → Application: IP20 protection and screw terminal connection simplify safe wiring and maintenance, while a compact 44 mm width and 74 mm depth save enclosure space. Application: Control cabinets with limited footprint. Feature → Business Impact → Application: Short-time and mechanical switching capabilities (AC-1, AC-3, and DC-13 ratings) support reliable, high-cycle operation in demanding environments. Application: High-demand production lines with frequent switching. Feature → Business Impact → Application: Comprehensive compliance suite (CE, UL, RoHS) supports multi-market deployment and lowers regulatory risk. Application: Global installations requiring standard certifications and traceability.

Get a Quick Quote for a ABB 1SBL921074R8810

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SBL921074R8810? Enquire Now

FAQs

The 1SBL921074R8810 is a three-pole block contactor with 3 NO main contacts and 1 NO auxiliary contact, rated for 690 V and up to 27 A in AC-1 duty and 18 A in AC-3. Its coil accepts 230–240 V at 50 Hz or 240–260 V at 60 Hz, aligning with common PLC and drive outputs for seamless integration in 3-phase motor circuits.
Wire the single auxiliary NO contact in parallel or series with control logic as required to provide feedback or interlocking signals. The device uses screw terminals with IP20 protection, allowing safe, straightforward connections inside standard control panels. Ensure proper torque (1 N·m) on auxiliary and main terminals during installation to maintain reliability.
Yes, within its specified ambient range. The ABB contactor operates in environments from -25 to 55 °C with thermal overload relay fitted, and from -40 to 70 °C without it. For high-altitude or demanding locations, derating may be necessary, but the unit is designed for rugged industrial use and maintains performance across common manufacturing conditions.
The product carries CE and UL certifications, with additional RoHS compliance and regional declarations (CCC, CQC). These certifications support global deployment, allow customers to meet regulatory requirements in diverse markets, and ensure safety and reliability in electrical protection and motor-control applications.
The integrated auxiliary contact, compact footprint, and robust mechanical timing (9–16 ms energize/de-energize) minimize wiring complexity and downtime. With rated IP20 protection and reliable switching (AC-1/AC-3), maintenance intervals are extended, reducing total cost of ownership through fewer replacement parts, smoother automation integration, and consistent motor-control performance.