ABB 1SBL931074R2601 Block Contactor - UL/CE Certified
Part Number: 1SBL931074R2601
Quick Summary
Block Contactor ABB 1SBL931074R2601 reliably switches three-phase motors up to 690 V AC. It is designed to streamline panel wiring and minimize downtime with a compact block-type footprint and a built-in auxiliary contact for simplified control. This device supports front or side mounting add-on auxiliary blocks, reducing external hardware and easing future expansion. Compliance with CE and UL declarations, plus RoHS/REACH statements, ensures global deployment with confidence. For manufacturers seeking predictable performance, easy installation, and lower total cost of ownership, this ABB block contactor delivers robust reliability in demanding automation environments.
Product Information
Extended Description
1SBL931074R2601 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 105 V | 60 Hz 110 ... 127 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522398260
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3 main normally open contacts with 1 built-in normally closed auxiliary NC contact. Business Impact: Enables reliable 3-phase motor control with reduced external relay requirements, cutting panel complexity and spare-parts cost. Application: conveyors, pumps, and fans in OEM machinery. Feature: Control circuit voltage compatible with common control systems – 50 Hz 105 V or 60 Hz 110–127 V. Business Impact: Seamless integration into existing control panels without additional transformers. Application: automation cabinets and machine controls. Feature: Block-type design with a compact footprint (44 mm width, 74 mm depth, 74 mm height) and screw terminal connections. Business Impact: Saves space in tight control panels and simplifies wiring with secure connections. Application: machine mounting in limited enclosure space. Feature: Rated operational currents suitable for AC-1 and AC-3 operation across common voltages, plus a high short-time withstand capacity. Business Impact: Supports motor starting and continuous operation with predictable thermal margins, reducing downtime from contactor failures. Application: industrial drives and equipment with diverse motor loads. Feature: IP20 protection at coil terminals and durable insulation with RoHS/REACH compliance. Business Impact: Safer maintenance and long-term compliance with global regulatory standards. Application: installations requiring clean-room-grade electrical safety and environmental compliance. Feature: Add-on auxiliary blocks and compatibility with AX-series accessories. Business Impact: Easy expansion and configuration changes in the field, lowering maintenance time. Application: scalable control panels and modular automation systems.
Get a Quick Quote for a ABB 1SBL931074R2601
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL931074R2601?
Enquire Now
FAQs
Yes. This block contactor uses a standard AX-style 3-pole main contact design with a built-in NC auxiliary and supports add-on auxiliary blocks for front or side mounting. It integrates with common control voltages (105 V at 50 Hz or 110–127 V at 60 Hz) and screw terminals, simplifying retrofit projects and panel modernization.
For AC-3 operation at 690 V, the device supports up to 10 A to 32 A depending on voltage and temperature, while at 415 V and 55 °C it can reach 25 A, with other voltage cases up to 25 A at 220–240 V. For AC-1, rated currents vary by voltage, with 27–32 A at 220–690 V ranges. These figures help sizing for motor start and running scenarios.
The product carries CE and UL certifications, along with CCC, CQC, and REACH/RoHS declarations. It also aligns with relevant safety and environmental compliance standards, supporting global deployment in industrial automation projects.
Maximum mechanical switching frequency is 3600 cycles per hour, while electrical switching varies by duty: AC-1 up to 600 cycles/hour, AC-3 up to 1200 cycles/hour, and DC-13 up to 900 cycles/hour. The unit provides a fast coil operate time (9–16 ms) and release time (4–26 ms) for reliable control under typical plant cycles.
The contactor has a compact footprint of 44 mm width, 74 mm depth, and 74 mm height, with IP20 coil terminals. It supports screw terminal connections and add-on auxiliary blocks, enabling flexible front or side mounting. This makes it suitable for tight control panels in conveyors, pumps, and other automation equipment.