ABB 1SBL931074R8001 Contactor - UL/CSA 690V
Part Number: 1SBL931074R8001
Quick Summary
ABB 1SBL931074R8001 Contactor is designed to reliably switch 3-phase motors up to 690 V AC in industrial power circuits. Engineers often face crowded control panels, mismatched accessories, and lengthy commissioning when using legacy gear. This 3-pole block contactor integrates a built-in auxiliary contact, compact 44 mm width, and add-on auxiliary blocks to ease front or side mounting while preserving essential clearances. The unit carries CE and UL/CSA certifications, plus RoHS and REACH declarations to support global compliance. With CAD data availability and standard screw terminals, it enables faster installation, reduced wiring, and predictable maintenance—delivering lower total cost of ownership and higher panel density for modern machine design.
Product Information
Extended Description
1SBL931074R8001 ABB: AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100187L0203
Instructions and Manuals
AX 06~40A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
76.3 mm
Product Net Weight
0.326 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Auxiliary Circuit 690 V | Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz | Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A | acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 55 °C 27 A | (690 V) 40 °C 32 A | (690 V) 70 °C 23 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 25 A | (440 V) 55 °C 16 A | (500 V) 55 °C 14 A | (690 V) 55 °C 10 A | (380 / 400 V) 55 °C 25 A | (220 / 230 / 240 V) 55 °C 25 A
Rated Operational Current AC-15 (Ie)
(500 V) NC 2 | (500 V) 2 A | (690 V) 2 A | (24 / 127 V) 6 A | (220 / 240 V) 4 A | (380 / 400 V) 3 A | (400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W | (110 V) 1.1 A / 121 W | (125 V) 1.1 A / 138 W | (220 V) 0.55 A / 121 W | (250 V) 0.55 A / 138 W | (400 V) 2.8 A / 134 W | (500 V) 2 A / 144 W
Rated Operational Power AC-3 (Pe)
(415 V) 11 kW | (440 V) 9 kW | (500 V) 9 kW | (690 V) 9 kW | (380 / 400 V) 11 kW | (220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A | for 0.1 s 140 A | for 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour | (AC-15) 1200 cycles per hour | (AC-3) 1200 cycles per hour | (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions AC-1 per Pole 1.2 W | at Rated Operating Conditions AC-3 per Pole 0.35 W
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms | Between Coil De-energization and NO Contact Opening 4 ... 11 ms | Between Coil Energization and NC Contact Opening 7 ... 21 ms | Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening Torque
Auxiliary Circuit 1 N·m | Control Circuit 1 N·m | Main Circuit 1.2 N·m
Terminal Type
Screw Terminals
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 2 hp | (200 ... 208 V AC) Three Phase 7.5 hp | (220 ... 240 V AC) Three Phase 7.5 hp | (240 V AC) Single Phase 3 hp | (440 ... 480 V AC) Three Phase 15 hp | (550 ... 600 V AC) Three Phase 15 hp
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb | Control Circuit 9 in·lb | Main Circuit 11 in·lb
Full Load Amps Motor Use
(120 V AC) Single Phase 24 A | (200 ... 208 V AC) Three Phase 25.3 A | (220 ... 240 V AC) Three Phase 22 A | (240 V AC) Single Phase 17 A | (440 ... 480 V AC) Three Phase 21 A | (550 ... 600 V AC) Three Phase 17 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C | Close to Contactor without Thermal O/L Relay -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C | Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CB Certificate
AX 06~25A CB certification
CCC Certificate
9AKK107492A7089
CCS Certificate
CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactors
CQC Certificate
CQC Certificate, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX06, AX09, AX12, AX18, AX25, Made in China
Declaration of Conformity - CE
EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole Contactors
UL Certificate
UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25
Package Level 1 Units
box 1 piece
Package Level 1 Width
48 mm
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
79 mm
Package Level 1 Gross Weight
0.34 kg
Package Level 1 EAN
3471522398802
Package Level 2 Units
30 piece
Package Level 2 Width
240 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
145 mm
Package Level 2 Gross Weight
10.2 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3707329
Feature → The device is a 3 NO main contactors with 1 NC auxiliary contact, enabling centralized motor control with integrated signaling. Business Impact → Reduces wiring complexity, saves panel space, and simplifies wiring diagrams. Application → Suitable for conveyors, pumps, and machine tools where 3-phase motor control is required. Feature → Rated operational current AC-3 up to 25 A at several voltages (e.g., 415 V 25 A, 440 V 16 A, 690 V 10 A, 220/230/240 V 25 A). Business Impact → Supports typical motor loads without oversizing, improving energy efficiency and lowering component costs. Application → Industrial drives and contactor circuits in mid-range panel assemblies. Feature → Conventional Free-air Thermal Current Ith of 32 A (Θ = 40 °C) for open contactors and 16 A for the thermal overload range. Business Impact → Enhanced startup resilience and better thermal margins in frequent-start applications. Application → Packaging lines, sorting equipment, and high-cycle machinery. Feature → Compact footprint: Product Net Width 44 mm, Depth 74 mm, Height 76.3 mm, Weight 0.326 kg. Business Impact → Higher panel density, easier retrofits, and streamlined field installation. Application → Small to mid-sized control cabinets and modular automation layouts. Feature → IP20 protection for auxiliary, coil, and main terminations; Screw terminals with tightening torques of 1 N·m (auxiliary/control) and 1.2 N·m (main). Business Impact → Safer, reliable connections and straightforward maintenance. Application → Environments with clean, indoor coil and terminal regions. Feature → Compliance and compatibility: CE, UL/CSA, RoHS, REACH; CAD dimensional drawings; Add-on auxiliary blocks for front or side mounting. Business Impact → Simplified procurement, regulatory assurance, and quick integration with existing control architectures. Application → Global manufacturing sites and OEM panel builds.
Get a Quick Quote for a ABB 1SBL931074R8001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SBL931074R8001?
Enquire Now
FAQs
This 3-pole block contactor uses screw terminals and a compact 44 mm width, with a depth of 74 mm and height of 76.3 mm. It supports front or side mounting with add-on auxiliary blocks, and requires tightening torques of 1 N·m for auxiliary/control and 1.2 N·m for main terminals. Plan wiring diagrams accordingly and leverage the available CAD drawings to ensure accurate panel layouts.
For AC-3 duty, Ie is 25 A at 415 V, 16 A at 440 V, 14 A at 500 V, 10 A at 690 V, and 25 A at 220/230/240 V. For AC-1 ratings, values vary by voltage as listed in the datasheet, with higher current at lower voltages. These ratings support typical motor starting and running conditions in mid-range applications.
Yes. The control voltage is 50 Hz 220–230 V and 60 Hz 230–240 V, ensuring compatibility with standard European and North American mains supplies. This makes it straightforward to integrate with existing control systems without special transformers.
The device offers CE and UL/CSA certifications, along with RoHS and REACH declarations. It is designed for global compliance, supporting procurement across diverse regulatory environments and helping to reduce certification-related delays.
The AX-series block contactors support add-on auxiliary contact blocks for front or side mounting and CAD data for quick integration into assemblies. They also offer compatible accessories and standard screw-terminal wiring, improving installation speed and reliability in panel builds.